Real-time gait event detection for paraplegic FES walking
The DOI matches its Crossref record.
Abstract
A real-time method for the detection of gait events that occur during the electrically stimulated locomotion of paraplegic subjects is described. It consists of a two-level algorithm for the processing of sensor signals and the determination of gait event times. Sensor signals and information about the progression of the stimulator though its pre-specified stimulation "pattern" are processed by a machine intelligence (fuzzy logic) algorithm to determine an initial estimate of the patient's current phase of gait. This is then reviewed and modified by a second algorithm that removes spurious gait estimates, and determines gait event times. These gait event times are known to the system within approximately one-half of a gait cycle. The resulting gait event detection system was successfully evaluated on three subjects. Detection accuracy is not adversely affected by day-to-day gait variability. This work resolved technical and practical issues that previously limited the real time application of these methods. In particular, cosmetically acceptable insole force transducers were used. This gait event detector is designed for use in a real time controller for the automatic adjustment of the intensity and timing of stimulation while the subject is walking using functional electrical stimulation (FES).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Automatic detection of gait events using kinematic data
O’Connor, C. M., Thorpe, S. K., O’Malley, M. J., & Vaughan, C. L. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.016 · Cited by 557
Gait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“A similar two-level approach using FIS with a supervisory function was also implemented by [13].”
BackgroundMethodMethods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Metadata
- Authors
- Skelly, M. M., & Chizeck, H. J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-03
- Volume
- 9
- Issue
- 1
- Pages
- 59-68
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2100955016
- Cited by
- 157
- References
- 0
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time gait event detection for paraplegic FES walking. https://app.cochat.ai/papers/10.1109/7333.918277
- The paper
- Skelly, M. M., & Chizeck, H. J. (2001). Real-time gait event detection for paraplegic FES walking. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/7333.918277
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.