The DOI matches its Crossref record.
Implantation of silicon chip microphotodiode arrays into the cat subretinal space
Abstract
There are currently no therapies to restore vision to patients blinded by photoreceptor degeneration. This project concerns an experimental approach toward a semiconductor-based subretinal prosthetic designed to electrically stimulate the retina. The present study describes surgical techniques for implanting a silicon microphotodiode array in the cat subretinal space and subsequent studies of implant biocompatibility and durability. Using a single-port vitreoretinal approach, implants were placed into the subretinal space of the right eye of normal cats. Implanted retinas were evaluated post-operatively over a 10 to 27 month period using indirect ophthalmoscopy, fundus photography, electroretinography, and histology. Infrared stimulation was used to isolate the electrical response of the implant from that of the normal retina. Although implants continued to generate electrical current in response to light, the amplitude of the implant response decreased gradually due to dissolution of the implant's gold electrode. Electroretinograms recorded from implanted eyes had normal waveforms but were typically 10-15% smaller in amplitude than those in unimplanted left eyes. The nonpermeable silicon disks blocked choroidal nourishment to the retina, producing degeneration of the photoreceptors. The laminar structure of the inner retinal layers was preserved. Retinal areas located away from the implantation site appeared normal in all respects. These results demonstrate that silicon-chip microphotodiode-based implants can be successfully placed into the subretinal space. Gold electrode-based subretinal implants, however, appear to be unsuitable for long-term use due to electrode dissolution and subsequent decreased electrical activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
Self-citationHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Electronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133
Metadata
- Authors
- Chow, A. Y., Pardue, M. T., Chow, V. Y., Peyman, G. A., Liang, C., Perlman, J. I., & Peachey, N. S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-03
- Volume
- 9
- Issue
- 1
- Pages
- 86-95
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2111817251
- Cited by
- 184
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implantation of silicon chip microphotodiode arrays into the cat subretinal space. https://app.cochat.ai/papers/10.1109/7333.918281
- The paper
- Chow, A. Y., Pardue, M. T., Chow, V. Y., Peyman, G. A., Liang, C., Perlman, J. I., & Peachey, N. S. (2001). Implantation of silicon chip microphotodiode arrays into the cat subretinal space. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/7333.918281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.