The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
ECG analysis using nonlinear PCA neural networks for ischemia detection
Abstract
The detection of ischemic cardiac beats from a patient's electrocardiogram (EGG) signal is based on the characteristics of a specific part of the beat called the ST segment. The correct classification of the beats relies heavily on the efficient and accurate extraction of the ST segment features. An algorithm is developed for this feature extraction based on nonlinear principal component analysis (NLPCA). NLPCA is a method for nonlinear feature extraction that is usually implemented by a multilayer neural network. It has been observed to have better performance, compared with linear principal component analysis (PCA), in complex problems where the relationships between the variables are not linear. In this paper, the NLPCA techniques are used to classify each segment into one of two classes: normal and abnormal (ST+, ST-, or artifact). During the algorithm training phase, only normal patterns are used, and for classification purposes, we use only two nonlinear features for each ST segment. The distribution of these features is modeled using a radial basis function network (RBFN). Test results using the European ST-T database show that using only two nonlinear components and a training set of 1000 normal samples from each file produce a correct classification rate of approximately 80% for the normal beats and higher than 90% for the ischemic beats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximation by superpositions of a sigmoidal function
Cybenko, G. (1989) · Mathematics of Control, Signals, and Systems · doi:10.1007/bf02551274 · Cited by 13,883
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
DISCRETE- vs. CONTINUOUS-TIME NONLINEAR SIGNAL PROCESSING OF Cu ELECTRODISSOLUTION DATA
RICO-MARTÍNEZ, R., KRISCHER, K., KEVREKIDIS, I. G., KUBE, M. C., & HUDSON, J. L. (1992) · Chemical Engineering Communications · doi:10.1080/00986449208936084 · Cited by 144
Cited by
Yao, Q., Wang, R., Fan, X., Liu, J., & Li, Y. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.06.024 · Cited by 469
Principal Component Analysis in ECG Signal Processing
Castells, F., Laguna, P., Sörnmo, L., Bollmann, A., & Roig, J. M. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/74580 · Cited by 371
Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation
Rieta, J. J., Castells, F., Sanchez, C., Zarzoso, V., & Millet, J. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827272 · Cited by 263
Metadata
- Authors
- Stamkopoulos, T., Diamantaras, K., Maglaveras, N., & Strintzis, M.
- Venue
- IEEE Transactions on Signal Processing
- Published
- 1998
- Volume
- 46
- Issue
- 11
- Pages
- 3058-3067
- ISSN
- 1053-587X (ISSN-L)
- OpenAlex
- W2097000718
- Cited by
- 160
- References
- 4
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG analysis using nonlinear PCA neural networks for ischemia detection. https://app.cochat.ai/papers/10.1109/78.726818
- The paper
- Stamkopoulos, T., Diamantaras, K., Maglaveras, N., & Strintzis, M. (1998). ECG analysis using nonlinear PCA neural networks for ischemia detection. IEEE Transactions on Signal Processing. https://doi.org/10.1109/78.726818
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.