The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Source localization using recursively applied and projected (RAP) MUSIC
Abstract
A new method for source localization is described that is based on a modification of the well-known MUSIC algorithm. In classical MUSIC, the array manifold vector is projected onto an estimate of the signal subspace. Errors in the estimate of the signal subspace can make localization of multiple sources difficult. Recursively applied and projected (RAP) MUSIC uses each successively located source to form an intermediate array gain matrix and projects both the array manifold and the signal subspace estimate into its orthogonal complement. The MUSIC projection to find the next source is then performed in this reduced subspace. Special assumptions about the array manifold structure, such as Vandermonde or shift invariance, are not required. Using the metric of principal angles, we describe a general form of the RAP-MUSIC algorithm for the case of diversely polarized sources. Through a uniform linear array simulation with two highly correlated sources, we demonstrate the improved Monte Carlo error performance of RAP-MUSIC relative to MUSIC and two other sequential subspace methods: S and IES-MUSIC. We then demonstrate the more general utility of this algorithm for multidimensional array manifolds in a magnetoencephalography (MEG) source localization simulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
ESPRIT-estimation of signal parameters via rotational invariance techniques
Roy, R., & Kailath, T. (1989) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/29.32276 · Cited by 7,326
Two decades of array signal processing research: the parametric approach
Krim, H., & Viberg, M. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.526899 · Cited by 4,774
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A signal subspace approach to multiple emitter location and spectral estimation
Schmidt, R. O. (1981) · Medical Entomology and Zoology · Cited by 1,154
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationRecursive MUSIC: A framework for EEG and MEG source localization
Mosher, J. C., & Leahy, R. M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.725331 · Cited by 362
Self-citationDirection finding with an array of antennas having diverse polarizations
Ferrara, E., & Parks, T. W. (1983) · IRE Transactions on Antennas and Propagation · doi:10.1109/tap.1983.1143038 · Cited by 241
Spatial-spectrum estimation in a location sector
Buckley, K. M., & Xu, X. L. (1990) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/29.103086 · Cited by 116
On the performance of signal-subspace processing-- Part I: Narrow-band systems
Wang, H., & Kaveh, M. (1986) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1986.1164957 · Cited by 115
Flagged first, then by citations
Research works printed but not linked: 1
- golub, 1984, Matrix Computations
Cited by
Sorted by citations
Baillet, S., Mosher, J., & Leahy, R. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,846
Self-citationReview on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
EEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S. I., Anderson, E. W., Li, K., & Tucker, D. M. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 347
Rank Awareness in Joint Sparse Recovery
Davies, M. E., & Eldar, Y. C. (2012) · IEEE Transactions on Information Theory · doi:10.1109/tit.2011.2173722 · Cited by 340
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 308
Self-citationElectrophysiological Imaging of Brain Activity and Connectivity—Challenges and Opportunities
He, B., Yang, L., Wilke, C., & Yuan, H. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2139210 · Cited by 300
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Huang, Y., Parra, L. C., & Haufe, S. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 252
Rossini, P. M., Iorio, R. D., Vecchio, F., Anfossi, M., Babiloni, C., Bozzali, M., Bruni, A. C., Cappa, S. F., Escudero, J., Fraga, F. J., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.03.003 · Cited by 257
Evaluation of EEG localization methods using realistic simulations of interictal spikes
Grova, C., Daunizeau, J., Lina, J.-M., Bénar, C., Benali, H., & Gotman, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.053 · Cited by 59
Ammari, H. M., Яковлева, Е., & Lesselier, D. (2005) · Multiscale Modeling and Simulation · doi:10.1137/040610854 · Cited by 198
Soltanaghai, E., Kalyanaraman, A., & Whitehouse, K. (2018) · International Conference on Mobile Systems, Applications, and Services · doi:10.1145/3210240.3210347 · Cited by 196
A Review of Issues Related to Data Acquisition and Analysis in EEG/MEG Studies
Puce, A., & Hämäläinen, M. (2017) · Brain Sciences · doi:10.3390/brainsci7060058 · Cited by 194
A survey of methods used for source localization using EEG signals
Jatoi, M. A., Kamel, N., Malik, A. S., Faye, I., & Begum, T. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.01.009 · Cited by 175
Multimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
EEG based brain source localization comparison of sLORETA and eLORETA
Jatoi, M. A., Kamel, N., Malik, A. S., & Faye, I. (2014) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-014-0308-3 · Cited by 160
Baillet, S., Riera, J. J., Marin, G., Mangin, J., Aubert, J., & Garnero, L. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/306 · Cited by 156
EEG Source Localization and Imaging Using Multiple Signal Classification Approaches
Mosher, J. C., Baillet, S., & Leahy, R. M. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00004 · Cited by 137
Self-citation(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134
Independent component analysis for EEG source localization
Евгеньевич, Ж. Л., Weinstein, D. M., & Johnson, C. R. (2000) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.844386 · Cited by 133
A Simulation Framework for Benchmarking EEG-Based Brain Connectivity Estimation Methodologies
Haufe, S., & Ewald, A. (2016) · Brain Topography · doi:10.1007/s10548-016-0498-y · Cited by 133
Combining sparsity and rotational invariance in EEG/MEG source reconstruction
Haufe, S., Nikulin, V. V., Ziehe, A., Müller, K.-R., & Nolte, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.246 · Cited by 130
Independent Components of Magnetoencephalography: Localization
Tang, A. C., Pearlmutter, B. A., Malaszenko, N. A., Phung, D. B., & Reeb, B. C. (2002) · Neural Computation · doi:10.1162/089976602760128036 · Cited by 112
Ossadtchi, A., Baillet, S., Mosher, J. C., Thyerlei, D., Sutherling, W., & Leahy, R. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.036 · Cited by 104
Self-citationRapidly recomputable EEG forward models for realistic head shapes
Ermer, J. J., Mosher, J. C., Baillet, S., & Leahy, R. M. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/324 · Cited by 103
Self-citationLarge-scale EEG/MEG source localization with spatial flexibility
Haufe, S., Tomioka, R., Dickhaus, T., Sannelli, C., Blankertz, B., Nolte, G., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.003 · Cited by 113
EEG extended source localization: Tensor-based vs. conventional methods
Becker, H., Albera, L., Comon, P., Haardt, M., Birot, G., Wendling, F., Gavaret, M., Bénar, C., & Merlet, I. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.043 · Cited by 96
Magnetoencephalography in Epilepsy
Knowlton, R. C., & Shih, J. J. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.04012.x · Cited by 93
Hämäläinen, M., & Hari, R. (2002) · Elsevier eBooks · doi:10.1016/b978-012693019-1/50012-5 · Cited by 89
Multivariate Machine Learning Methods for Fusing Multimodal Functional Neuroimaging Data
Dähne, S., Bieszmann, F., Samek, W., Haufe, S., Goltz, D., Gundlach, C., Villringer, A., Fazli, S., & Müller, K. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2425807 · Cited by 88
The 3D topography of MEG source localization accuracy: effects of conductor model and noise
Tarkiainen, A., Liljeström, M., Seppä, M., & Salmelin, R. H. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00195-0 · Cited by 81
Oblique Projections for Direction-of-Arrival Estimation With Prior Knowledge
Boyer, R., & Bouleux, G. (2008) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.909348 · Cited by 81
CSI Fingerprinting Localization With Low Human Efforts
Tong, X., Wan, Y., Li, Q., Tian, X., & Wang, X. (2020) · IEEE/ACM Transactions on Networking · doi:10.1109/tnet.2020.3035210 · Cited by 80
Localization of realistic cortical activity in MEG using current multipoles
Jerbi, K., Baillet, S., Mosher, J. C., Nolte, G., Garnero, L., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.02.010 · Cited by 77
Self-citationMarzetti, L., Gratta, C. D., & Nolte, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.250 · Cited by 76
UAV Detection and Localization Based on Multi-Dimensional Signal Features
Nie, W., Han, Z.-C., Yi, L., He, W., Xie, L., Yang, X., & Zhou, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3105229 · Cited by 74
An alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73
Jean Daunizeau, A., Mattout, J., Clonda, D., Goulard, B., Benali, H., & Lina, J.-M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869791 · Cited by 73
Subspace Methods and Exploitation of Special Array Structures
Haardt, M., Pesavento, M., Roemer, F., & Korso, M. N. E. (2014) · Academic press library in signal processing · doi:10.1016/b978-0-12-411597-2.00015-1 · Cited by 67
Multi-Resolution FOCUSS: A Source Imaging Technique Applied to MEG Data
Moran, J. E., Bowyer, S. M., & Tepley, N. (2005) · Brain Topography · doi:10.1007/s10548-005-7896-x · Cited by 66
Paired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
Self-citationAn Extension Of The Music Algorithm To Broadband Scenarios Using Polynomial Eigenvalue Decomposition
Alrmah, M. A., Lambotharan, S., & Weiss, S. (2011) · Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) · doi:10.5281/zenodo.42731 · Cited by 62
Moiseev, A., Gaspar, J. M., Schneider, J. A., & Herdman, A. T. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.081 · Cited by 61
Christian, H., Pierau, S. S., Freitag, C. M., Roeper, J., Ziemann, U., & Bender, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050073 · Cited by 60
Multistatic Response Matrix of a 3-D Inclusion in Half Space and MUSIC Imaging
Яковлева, Е., Gdoura, S., Lesselier, D., & Perrusson, G. (2007) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2007.904103 · Cited by 58
Biomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 59
Localization of extended brain sources from EEG/MEG: The ExSo-MUSIC approach
Birot, G., Albera, L., Wendling, F., & Merlet, I. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.054 · Cited by 55
Dynamical MEG source modeling with multi‐target Bayesian filtering
Sorrentino, A., Parkkonen, L. T., Pascarella, A., Campi, C., & Piana, M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20786 · Cited by 55
Investigations of dipole localization accuracy in MEG using the bootstrap
Darvas, F., Rautiainen, M., Pantazis, D., Baillet, S., Benali, H., Mosher, J. C., Garnero, L., & Leahy, R. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.045 · Cited by 55
Self-citationFunctional source separation from magnetoencephalographic signals
Barbati, G., Sigismondi, R., Zappasodi, F., Porcaro, C., Graziadio, S., Valente, G., Balsi, M., Rossini, P. M., & Tecchio, F. (2006) · Human Brain Mapping · doi:10.1002/hbm.20232 · Cited by 51
Tecchio, F., Porcaro, C., Barbati, G., & Zappasodi, F. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.129163 · Cited by 51
Hallez, H., Vos, M. D., Vanrumste, B., Hese, P. V., Assecondi, S., Laere, K. V., Dupont, P. J., Paesschen, W. V., Huffel, S. V., & Lemahieu, I. A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.05.010 · Cited by 48
Noninvasive Imaging of the High Frequency Brain Activity in Focal Epilepsy Patients
Lu, Y., Worrell, G., Zhang, H., Yang, L., Brinkmann, B., Nelson, C., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2297332 · Cited by 46
Truncated RAP-MUSIC (TRAP-MUSIC) for MEG and EEG source localization
Mäkelä, N., Stenroos, M., Sarvas, J., & Ilmoniemi, R. J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.013 · Cited by 47
Wang, H., Wu, X., & Yao, L. (2020) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2020.3006847 · Cited by 47
Kobayashi, K., Akiyama, T., Nakahori, T., Yoshinaga, H., & Gotman, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00046-9 · Cited by 47
MapFi: Autonomous Mapping of Wi-Fi Infrastructure for Indoor Localization
Tong, X., Wang, H., Liu, X., & Qu, W. (2021) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2021.3108155 · Cited by 46
Ammari, H. M., Яковлева, Е., & Lesselier, D. (2005) · SIAM Journal on Scientific Computing · doi:10.1137/040612518 · Cited by 46
MEG and EEG Source Localization in Beamspace
Rodriguez-Rivera, A., Baryshnikov, B. V., VanVeen, B. D., & Wakai, R. T. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869764 · Cited by 45
Ding, L., & He, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878118 · Cited by 44
The Iterative Reweighted Mixed-Norm Estimate for Spatio-Temporal MEG/EEG Source Reconstruction
Strohmeier, D., Bekhti, Y., Haueisen, J., & Gramfort, A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553445 · Cited by 44
Magnetic Source Imaging of the Human Brain
Lu, Z., & Kaufman, L. (2003) · Psychology Press eBooks · doi:10.4324/9781410609175 · Cited by 43
Sparse EEG Source Localization Using Bernoulli Laplacian Priors
Costa, F., Batatia, H., Chaâri, L., & Tourneret, J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2450015 · Cited by 41
Park, W. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.107501 · Cited by 41
Magnetoencephalography and its Achilles' heel
Lütkenhöner, B. (2003) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2004.01.020 · Cited by 40
The impact of improved MEG–MRI co-registration on MEG connectivity analysis
Chella, F., Marzetti, L., Stenroos, M., Parkkonen, L. T., Ilmoniemi, R. J., Romani, G. L., & Pizzella, V. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.061 · Cited by 39
Sommariva, S., & Sorrentino, A. (2014) · Inverse Problems · doi:10.1088/0266-5611/30/11/114020 · Cited by 36
Maximum contrast beamformer for electromagnetic mapping of brain activity
Chen, Y., Cheng, C.-Y., Hsieh, J., & Chen, L. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878115 · Cited by 35
Sequential High-Resolution Direction Finding From Higher Order Statistics
Birot, G., Albera, L., & Chevalier, P. (2010) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2010.2049569 · Cited by 35
A Rao–Blackwellized particle filter for magnetoencephalography
Campi, C., Pascarella, A., Sorrentino, A., & Piana, M. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/2/025023 · Cited by 34
Reconstruction of a Small Inclusion in a Two-Dimensional Open Waveguide
Ammari, H. M., Яковлева, Е., & Kang, H. (2005) · SIAM Journal on Applied Mathematics · doi:10.1137/040615389 · Cited by 33
Kobayashi, K., Akiyama, T., Nakahori, T., Yoshinaga, H., & Gotman, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00047-0 · Cited by 33
Park, W., Kim, H. P., Lee, K., & Son, S. (2017) · Journal of Computational Physics · doi:10.1016/j.jcp.2017.07.035 · Cited by 32
Soltanaghai, E., Dongare, A., Prabhakara, A., Kumar, S., Rowe, A., & Whitehouse, K. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3448082 · Cited by 32
Multi-subject MEG/EEG source imaging with sparse multi-task regression
Janati, H., Bazeille, T., Thirion, B., Cuturi, M., & Gramfort, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116847 · Cited by 31
Probabilistic Structure Learning for EEG/MEG Source Imaging With Hierarchical Graph Priors
Liu, F., Wang, L., Lou, Y., Li, R.-C., & Purdon, P. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3025608 · Cited by 26
Miao, L., Zhang, J. J., Chakrabarti, C., & Papandreou‐Suppappola, A. (2012) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2012.2226172 · Cited by 31
Eddy, T., Nomura, W., Cheng, J., Taromaru, M., Watanabe, Y., & Ohira, T. (2008) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2008.927501 · Cited by 29
Harmony: EEG/MEG Linear Inverse Source Reconstruction in the Anatomical Basis of Spherical Harmonics
Petrov, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044439 · Cited by 28
MNE: Software for Acquiring, Processing, and Visualizing MEG/EEG Data
Esch, L., Dinh, C., Larson, E., Engemann, D. A., Jas, M., Khan, S., Gramfort, A., & Hämäläinen, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_59 · Cited by 29
Advanced Signal Processing Methods for Characterization of Schizophrenia
Masychev, K., Ciprian, C., Ravan, M., Reilly, J. P., & MacCrimmon, D. J. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3011842 · Cited by 29
Somogyvári, Z., Cserpán, D., Ulbert, I., & Érdi, P. (2012) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2012.08249.x · Cited by 28
Data-driven parceling and entropic inference in MEG
Lapalme, E., Lina, J., & Mattout, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.067 · Cited by 28
Matching Pursuit and Source Deflation for Sparse EEG/MEG Dipole Moment Estimation
Wu, S. C., & Swindlehurst, A. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2253101 · Cited by 27
Improving Noise Robustness in Subspace-Based Joint Sparse Recovery
Kim, J. M., Lee, O. K., & Ye, J. C. (2012) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2012.2211591 · Cited by 27
Efficient Localization of Synchronous EEG Source Activities Using a Modified RAP-MUSIC Algorithm
Liu, H., & Schimpf, P. H. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870236 · Cited by 27
Latif, M. A., Sanei, S., Chambers, J. A., & Shoker, L. (2006) · IEEE Signal Processing Letters · doi:10.1109/lsp.2005.862622 · Cited by 26
Dipole localization using simulated intracerebral EEG
Chang, N., Gulrajani, R. M., & Gotman, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.002 · Cited by 26
Minimum Overlap Component Analysis (MOCA) of EEG/MEG data for more than two sources
Nolte, G., Marzetti, L., & Valdes-Sosa, P. A. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.07.006 · Cited by 25
STRAPS: A Fully Data-Driven Spatio-Temporally Regularized Algorithm for M/EEG Patch Source Imaging
Liu, K., Yu, Z. L., Wu, W., Gu, Z., & Li, Y. (2015) · International Journal of Neural Systems · doi:10.1142/s0129065715500161 · Cited by 25
Graph Regularized EEG Source Imaging with In-Class Consistency and Out-Class Discrimination
Liu, F., Rosenberger, J., Lou, Y., Hosseini, R., Su, J.-Z., & Wang, S.-Y. (2017) · IEEE Transactions on Big Data · doi:10.1109/tbdata.2017.2756664 · Cited by 23
MEG Source Imaging Using Multipolar Expansions
Mosher, J. C., Leahy, R. M., Shattuck, D. W., & Baillet, S. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_2 · Cited by 25
Self-citationBender, S., Becker, D., Oelkers‐Ax, R., & Weisbrod, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.009 · Cited by 24
Projection Versus Prewhitening for EEG Interference Suppression
Wu, S. C., Swindlehurst, A. L., Wang, P. T., & Nenadić, Z. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2187335 · Cited by 24
BEM based solution of forward problem for brain source estimation
Jatoi, M. A., Kamel, N., Faye, I., Malik, A. S., Sánchez‐Bornot, J. M., & Begum, T. (2015) · IEEE International Conference on Signal and Image Processing Applications (ICSIPA) · doi:10.1109/icsipa.2015.7412186 · Cited by 24
A Machine Learning Approach Using Effective Connectivity to Predict Response to Clozapine Treatment
Ciprian, C., Masychev, K., Ravan, M., Reilly, J. P., & MacCrimmon, D. J. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3019685 · Cited by 24
Self-Consistent MUSIC: An approach to the localization of true brain interactions from EEG/MEG data
Avarvand, F. S., Ewald, A., & Nolte, G. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.054 · Cited by 23
Brain Source Localization in Head Harmonics Domain
Giri, A., Kumar, L., & Gandhi, T. K. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3026511 · Cited by 23
An in–vivo validation of ESI methods with focal sources
Pascarella, A., Mikulan, E., Sciacchitano, F., Sarasso, S., Rubino, A., Sartori, I., Cardinale, F., Zauli, F. M., Avanzini, P., Nobili, L., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120219 · Cited by 23
Phase shift invariant imaging of coherent sources (PSIICOS) from MEG data
Ossadtchi, A. E., Altukhov, D., & Jerbi, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.031 · Cited by 23
Metadata
- Authors
- Mosher, J. C., & Leahy, R. M.
- Affiliations
- Los Alamos National Laboratory (US)
- University of Southern California (US)
- Venue
- IEEE Transactions on Signal Processing
- Published
- 1999
- Volume
- 47
- Issue
- 2
- Pages
- 332-340
- ISSN
- 1053-587X (ISSN-L)
- OpenAlex
- W2126767504
- Cited by
- 398
- References
- 16
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 11 · 2023: 15 · 2022: 18 · 2021: 19 · 2020: 17 · 2019: 16 · 2018: 20 · 2017: 24 · 2016: 8 · 2015: 19 · 2014: 16 · 2013: 15 · 2012: 17
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Signal Processing (publishedVersion)
- Funders
- University of Southern California
- Villanova University
- Topics
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
- Physical Sciences › Computer Science › Artificial Intelligence › Target Tracking and Data Fusion in Sensor Networks
- Keywords
- source localization, rap music, MUSIC algorithm, signal subspace estimation, principal angles, correlated sources, uniform linear array, magnetoencephalography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review