Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record.

Bent-beam strain sensors

Gianchandani, Y.B., Najafi, K. · 1996 · Journal of Microelectromechanical Systems

Abstract

We examine a new class of sensitive and compact passive strain sensors that utilize a pair of narrow bent beams with an apex at their mid-points. The narrow beams amplify and transform deformations caused by residual stress into opposing displacements of the apices, where vernier scales are positioned to quantify the deformation. An analytical method to correlate vernier readings to residual stress is outlined, and its results are corroborated by finite-element modeling. It is shown that tensile and compressive residual stress levels below 10 MPa, corresponding to strains below 6/spl times/10/sup -5/ can be measured in a 1.5-/spl mu/m-thick layer of polysilicon using a pair of beams that are 2 /spl mu/m wide, 200 /spl mu/m long, and bent 0.05 radians (2.86/spl deg/) to the long axis of the device. Experimental data is presented from bent-beam strain sensors that were fabricated from boron-doped single crystal silicon using the dissolved wafer process and from polycrystalline silicon using surface micromachining. Measurements from these devices agree well with those obtained by other methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/84.485216

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Gianchandani, Y. B., & Najafi, K.
Venue
Journal of Microelectromechanical Systems
Published
1996-03
Volume
5
Issue
1
Pages
52-58
ISSN
1057-7157 (ISSN-L)
OpenAlex
W2152873042
Cited by
177
References
0
FWCI
6.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bent-beam strain sensors. https://app.cochat.ai/papers/10.1109/84.485216
The paper
Gianchandani, Y. B., & Najafi, K. (1996). Bent-beam strain sensors. Journal of Microelectromechanical Systems. https://doi.org/10.1109/84.485216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.