The DOI matches its Crossref record.
Fabrication and characterization of surface micromachined capacitive ultrasonic immersion transducers
Abstract
In this paper, several innovative steps used in fabricating surface micromachined capacitive ultrasonic immersion transducers are reported. The investigation is focused on major steps in the device fabrication processes necessary to optimize transducer performance. Such steps include membrane formation, vacuum sealing, and electrode metallization. Three transducer membrane structures are evaluated: a nitride membrane with an oxide sacrificial layer; a polysilicon membrane with an oxide sacrificial layer; and a nitride membrane with a polysilicon sacrificial layer. Three vacuum sealing mechanisms are compared, each of which requires a different degree of lithographic sophistication, uses a particular sealing mechanism, and results in a sealed cavity. Submicrometer via sealing requires sophisticated lithography but is amenable to LPCVD nitride, LTO, and other sealing procedures. Standard g-line lithography results in vies which seal only with high sticking coefficient species, such as LTO. A novel etch channel structure, which results in lateral sealing and requires neither sophisticated lithography nor a particular sealing material, is demonstrated. Finally, the impact of electrode metallization on the impedance, bandwidth, and efficiency of the transducers is discussed. The experiments in the paper are guided by theoretical analysis and computer simulations when applicable. The new process results in optimized devices which have a broad-band 50-/spl Omega/ real part impedance in the megahertz range. A transducer dynamic range in excess of 100 dB is achieved around 4.5 MHz. An untuned transducer exhibits more than 100% bandwidth when connected to electronics with 50-/spl Omega/ input impedance. In addition, beam pattern measurement shows the immersion devices behave like uniform piston transducers and are readily suitable for array applications. The fabrication techniques and results herein reported indicate that surface micromachined ultrasonic immersion transducers are an attractive alternative to piezoelectric transducers in immersion applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current micropump technologies and their biomedical applications
Amirouche, F., Zhou, Y., & Johnson, T. (2009) · Microsystem Technologies · doi:10.1007/s00542-009-0804-7 · Cited by 332
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, B. T., & Oralkan, Ö. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054004 · Cited by 332
Self-citationPhinney, L. M., Serrano, J. R., Piekos, E. S., Torczynski, J. R., Gallis, M. A., & Gorby, A. D. (2010) · Journal of Heat Transfer · doi:10.1115/1.4000965 · Cited by 16
Metadata
- Authors
- Jin, X., Ladabaum, I., Degertekin, F. L., Calmes, S., & Khuri-Yakub, B. T.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 1999-03
- Volume
- 8
- Issue
- 1
- Pages
- 100-114
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2149126773
- Cited by
- 171
- References
- 0
- FWCI
- 12.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication and characterization of surface micromachined capacitive ultrasonic immersion transducers. https://app.cochat.ai/papers/10.1109/84.749409
- The paper
- Jin, X., Ladabaum, I., Degertekin, F. L., Calmes, S., & Khuri-Yakub, B. T. (1999). Fabrication and characterization of surface micromachined capacitive ultrasonic immersion transducers. Journal of Microelectromechanical Systems. https://doi.org/10.1109/84.749409
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.