The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Open accessAbstract
Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure, and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated frontend electronic circuits we developed and their use for 2-D and 3-D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a MEMS technology for many medical diagnostic and therapeutic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mellor, D. H. (1981) · Cited by 1,693
Surface micromachined capacitive ultrasonic transducers
Ladabaum, I., Jin, X., Soh, H. T., Atalar, A., & Khuri-Yakub, B. T. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.677612 · Cited by 581
Self-citationA surface micromachined electrostatic ultrasonic air transducer
Haller, M. I., & Khuri-Yakub, B. T. (1996) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.484456 · Cited by 397
Self-citationIntegration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
Wygant, I. O., Zhuang, X., Yeh, D. T., Oralkan, O., Ergun, A. S., Karaman, M., & Khuri-Yakub, B. T. (2008) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.652 · Cited by 248
Self-citationVolumetric ultrasound imaging using 2-D CMUT arrays
Oralkan, O., Ergun, A. S., Cheng, C.-H., Johnson, J. A., Karaman, M., Lee, T. H., & Khuri-Yakub, B. T. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1251142 · Cited by 187
Self-citationJin, X., Ladabaum, I., Degertekin, F. L., Calmes, S., & Khuri-Yakub, B. T. (1999) · Journal of Microelectromechanical Systems · doi:10.1109/84.749409 · Cited by 171
Self-citationSurface micromachined ultrasound transducers in CMOS technology
Eccardt, P.-C., Niederer, K., Scheiter, T., & Hierold, C. (2002) · 1996 IEEE Ultrasonics Symposium. Proceedings · doi:10.1109/ultsym.1996.584150 · Cited by 165
Wygant, I. O., Jamal, N. S., Lee, H. J., Nikoozadeh, A., Oralkan, Ö., Karaman, M., & Khuri-Yakub, B. T. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1297 · Cited by 153
Self-citationWang, Y., Stephens, D. N., & O’Donnell, M. P. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1159845 · Cited by 71
Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics
Daft, C. M. W., Calmes, S., da Graca, D., Patel, K., Wagner, P., & Ladabaum, I. (2005) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2004.1417770 · Cited by 63
Cited by
Qiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S. (2015) · Sensors · doi:10.3390/s150408020 · Cited by 395
Looking at sound: optoacoustics with all-optical ultrasound detection
Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0036-7 · Cited by 374
Review of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
Enriquez, A., Saenz, L. C., Rosso, R., Silvestry, F. E., Callans, D., Marchlinski, F. E., & Garcia, F. (2018) · Circulation · doi:10.1161/circulationaha.117.031343 · Cited by 262
Ozdas, M. S., Shah, A. S., Johnson, P. M., Patel, N., Marks, M., Yasar, T. B., Stalder, U., Bigler, L., von der Behrens, W., Sirsi, S. R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18059-7 · Cited by 63
Metadata
- Authors
- Khuri-Yakub, B. T., & Oralkan, Ö.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2011-04-28
- Volume
- 21
- Issue
- 5
- Pages
- 054004
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2150266890
- Cited by
- 332
- References
- 12
- FWCI
- 32.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capacitive micromachined ultrasonic transducers for medical imaging and therapy. https://app.cochat.ai/papers/10.1088/0960-1317/21/5/054004
- The paper
- Khuri-Yakub, B. T., & Oralkan, Ö. (2011). Capacitive micromachined ultrasonic transducers for medical imaging and therapy. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/21/5/054004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.