The DOI matches its Crossref record.
A traction stress sensor array for use in high-resolution robotic tactile imaging
Abstract
A high resolution large-area array capable of resolving the three independent components of a 2D triaxial contact stress profile has been developed. The array, composed of 4096 (64/spl times/64) individual stress sensing elements, was constructed with a fully CMOS-compatible fabrication process, allowing integration of the sensing structures with digital control circuitry. The individual array elements have been shown to demonstrate linear responses to both applied normal stress (1.59 mV/kPa, 0-35 kPa) and applied shear stress (0.32 mV/kPa, 0-60 kPa). A spatial resolution comparable to the spacing of the papillary ridges of the human dermis (/spl ap/300 /spl mu/m) has been achieved within the 1.92/spl times/1.92 cm active sensing area of the array. Descriptions of the sensor structure, the required signal conditioning, and the array architecture are presented in this paper. The results of electrical and mechanical characterization studies are also outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interdigital sensors and transducers
Mamishev, A. V., Sundara-Rajan, K., Yang, F., Du, Y., & Zahn, M. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2004.826603 · Cited by 578
Conductive polymer-based sensors for biomedical applications
Nambiar, S., & Yeow, J. T. W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.046 · Cited by 513
Directions Toward Effective Utilization of Tactile Skin: A Review
Dahiya, R. S., Mittendorfer, P., Valle, M., Cheng, G., & Lumelsky, V. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2279056 · Cited by 428
Recent Developments in Polymer MEMS
Liu, C. (2007) · Advanced Materials · doi:10.1002/adma.200701709 · Cited by 422
A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment
Lee, H.-K., Chang, S.-I., & Yoon, E. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886021 · Cited by 396
Metadata
- Authors
- Kane, B. J., Cutkosky, M. R., & Kovacs, G. T. A.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-12
- Volume
- 9
- Issue
- 4
- Pages
- 425-434
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2154352415
- Cited by
- 235
- References
- 0
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A traction stress sensor array for use in high-resolution robotic tactile imaging. https://app.cochat.ai/papers/10.1109/84.896763
- The paper
- Kane, B. J., Cutkosky, M. R., & Kovacs, G. T. A. (2000). A traction stress sensor array for use in high-resolution robotic tactile imaging. Journal of Microelectromechanical Systems. https://doi.org/10.1109/84.896763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.