The DOI matches its Crossref record.
A traction stress sensor array for use in high-resolution robotic tactile imaging
Abstract
A high resolution large-area array capable of resolving the three independent components of a 2D triaxial contact stress profile has been developed. The array, composed of 4096 (64/spl times/64) individual stress sensing elements, was constructed with a fully CMOS-compatible fabrication process, allowing integration of the sensing structures with digital control circuitry. The individual array elements have been shown to demonstrate linear responses to both applied normal stress (1.59 mV/kPa, 0-35 kPa) and applied shear stress (0.32 mV/kPa, 0-60 kPa). A spatial resolution comparable to the spacing of the papillary ridges of the human dermis (/spl ap/300 /spl mu/m) has been achieved within the 1.92/spl times/1.92 cm active sensing area of the array. Descriptions of the sensor structure, the required signal conditioning, and the array architecture are presented in this paper. The results of electrical and mechanical characterization studies are also outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tactile Sensing—From Humans to Humanoids
Dahiya, R. S., Metta, G., Valle, M., & Sandini, G. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2033627 · Cited by 1,851
Review: Semiconductor Piezoresistance for Microsystems
Barlian, A. A., Park, W.-T., Mallon, J. R., Rastegar, A. J., & Pruitt, B. L. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2013612 · Cited by 949
Interdigital sensors and transducers
Mamishev, A. V., Sundara-Rajan, K., Yang, F., Du, Y., & Zahn, M. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2004.826603 · Cited by 578
Conductive polymer-based sensors for biomedical applications
Nambiar, S., & Yeow, J. T. W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.046 · Cited by 513
Ultrastretchable and Self-Healing Double-Network Hydrogel for 3D Printing and Strain Sensor
Liu, S., & Li, L. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07445 · Cited by 456
Flexible Tactile Sensing Based on Piezoresistive Composites: A Review
Stassi, S., Cauda, V., Canavese, G., & Pirri, C. (2014) · Sensors · doi:10.3390/s140305296 · Cited by 433
Directions Toward Effective Utilization of Tactile Skin: A Review
Dahiya, R. S., Mittendorfer, P., Valle, M., Cheng, G., & Lumelsky, V. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2279056 · Cited by 428
Recent Developments in Polymer MEMS
Liu, C. (2007) · Advanced Materials · doi:10.1002/adma.200701709 · Cited by 422
A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment
Lee, H.-K., Chang, S.-I., & Yoon, E. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886021 · Cited by 396
Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.921727 · Cited by 350
Development of polyimide flexible tactile sensor skin
Engel, J., Chen, J., & Liu, C. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/13/3/302 · Cited by 291
Tactile sensing in intelligent robotic manipulation – a review
Tegin, J., & Wikander, J. (2005) · Industrial Robot: An International Journal · doi:10.1108/01439910510573318 · Cited by 290
Polymer micromachined multimodal tactile sensors
Engel, J., Chen, J., Fan, Z., & Liu, C. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.05.037 · Cited by 224
Adaptive readout approaches of resistive sensor array for wearable electronics applications
Zhang, Z., Chen, X., Shu, L., & Xu, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.113524 · Cited by 7
Metadata
- Authors
- Kane, B. J., Cutkosky, M. R., & Kovacs, G. T. A.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-12
- Volume
- 9
- Issue
- 4
- Pages
- 425-434
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2154352415
- Cited by
- 235
- References
- 0
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.