High-cycle fatigue of single-crystal silicon thin films
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
When subjected to alternating stresses, most materials degrade, e.g., suffer premature failure, due to a phenomenon known as fatigue. It is generally accepted that in brittle materials, such as ceramics, fatigue can only take place in toughened solids, i.e., premature fatigue failure would not be expected in materials such as single crystal silicon. The results of this study, however, appear to be at odds with the current understanding of brittle material fatigue. Twelve thin-film (/spl sim/20 /spl mu/m thick) single crystal silicon specimens were tested to failure in a controlled air environment (30/spl plusmn/0.1/spl deg/C, 50/spl plusmn/2% relative humidity). Damage accumulation and failure of the notched cantilever beams were monitored electrically during the "fatigue life" test. Specimen lives ranged from about 10 s to 48 days, or 1/spl times/106 to 1/spl times/1011 cycles before failure over stress amplitudes ranging from approximately 4 to 10 GPa. A variety of mechanisms are discussed in light of the fatigue life data and fracture surface evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Properties of Crystals
(2007) · Materials Today · doi:10.1016/s1369-7021(07)70138-4 · Cited by 7,769
Lawn, B. (1993) · Cambridge University Press eBooks · doi:10.1017/cbo9780511623127 · Cited by 4,759
Calculated elastic constants for stress problems associated with semiconductor devices
Brantley, W. A. (1973) · Journal of Applied Physics · doi:10.1063/1.1661935 · Cited by 1,203 · cited 1×
“Typical fracture surfaces of specimens with short lives ( 10 cycles) and longer lives ( 10 cycles) re shown in Fig.”
BackgroundStress Corrosion and Static Fatigue of Glass
Wiederhorn, S. M., & Bolz, L. H. (1970) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1970.tb15962.x · Cited by 1,024 · cited 1×
“stress corrosion cracking [31]–[33] is responsible for the fatigue”
BackgroundMechanisms of fatigue-crack propagation in ductile and brittle solids
Ritchie, R. O. (1999) · International Journal of Fracture · doi:10.1023/a:1018655917051 · Cited by 962 · cited 1×
“, polycrystalline ceramics and ordered intermetallics, but by a conceptually different mechanism [1], [2].”
BackgroundSelf-citationDirect Measurements of the Surface Energies of Crystals
Gilman, J. J. (1960) · Journal of Applied Physics · doi:10.1063/1.1735524 · Cited by 837
Baxter, L. K. (1996) · doi:10.1109/9780470544228 · Cited by 631
Physical Properties of Crystals, Their Representation by Tensors and Matrices
Finger, L. W. (1983) · Eos · doi:10.1029/eo064i045p00643-01 · Cited by 313
Slow Crack Growth in Single-Crystal Silicon
Connally, J. A., & Brown, S. B. (1992) · Science · doi:10.1126/science.256.5063.1537 · Cited by 190 · cited 2×
“Upon completion of the test, the measured lifetimes, the compliance change, and the resulting fracture surfaces were evaluated.”
MethodSelf-citationA Chemical Interpretation of Static Fatigue
Wiederhorn, S. M. (1972) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1972.tb11215.x · Cited by 136
Materials reliability in MEMS devices
Brown, S. B., Arsdell, W. V., & Muhlstein, C. L. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.613720 · Cited by 109 · cited 1×
“Upon completion of the test, the measured lifetimes, the compliance change, and the resulting fracture surfaces were evaluated.”
MethodSelf-citationFluorine-silicon reactions and the etching of crystalline silicon
de Walle, C. G. V., McFeely, F. R., & Pantelides, S. T. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.1867 · Cited by 105
Influence of oxygen precipitation along dislocations on the strength of silicon crystals
Yonenaga, I., & Sumino, K. (1996) · Journal of Applied Physics · doi:10.1063/1.362881 · Cited by 89
Micro tensile-test of silicon film having different crystallographic orientations
Sato, K., Shikida, M., YOSHIOKA, T., Ando, T., & Kawabata, T. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.613721 · Cited by 22
Cited by
Temporal color mixing and dynamic beam shaping with silicon metasurfaces
Holsteen, A. L., Cihan, A. F., & Brongersma, M. L. (2019) · Science · doi:10.1126/science.aax5961 · Cited by 252
Material Fatigue and Reliability of MEMS Accelerometers
Xiong, X., Wu, Y.-L., & Jone, W.-B. (2008) · 2008 IEEE International Symposium on Defect and Fault Tolerance of VLSI Systems · doi:10.1109/dft.2008.37 · Cited by 33
“Ever since, many researchers have made tremendous efforts to explore the fatigue mechanism and behavior of both single crystal silicon [11] and poly-silicon [12][13].”
Background
Metadata
- Authors
- Muhlstein, C. L., Brown, S. B., & Ritchie, R. O.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2001
- Volume
- 10
- Issue
- 4
- Pages
- 593-600
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2170038799
- Cited by
- 234
- References
- 14
- FWCI
- 26.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.