The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
A system for the analysis of foot and ankle kinematics during gait
Abstract
A five-camera Vicon (Oxford Metrics, Oxford, England) motion analysis system was used to acquire foot and ankle motion data. Static resolution and accuracy were computed as 0.86 +/- 0.13 mm and 98.9%, while dynamic resolution and accuracy were 0.1 +/- 0.89 and 99.4% (sagittal plane). Spectral analysis revealed high frequency noise and the need for a filter (6 Hz Butterworth low-pass) as used in similar clinical situations. A four-segment rigid body model of the foot and ankle was developed. The four rigid body foot model segments were 1) tibia and fibula, 2) calcaneus, talus, and navicular, 3) cuneiforms, cuboid, and metatarsals, and 4) hallux. The Euler method for describing relative foot and ankle segment orientation was utilized in order to maintain accuracy and ease of clinical application. Kinematic data from a single test subject are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldstein, H. (1951) · UCLA - Biblioteca de Ciencias y Tecnologia Felix Morales Bueno · Cited by 10,004
An Introduction to Statistical Methods and Data Analysis
(1994) · Technometrics · doi:10.1080/00401706.1994.10485832 · Cited by 5,346
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Abdel-Aziz, Y. I., & Karara, H. M. (2015) · Photogrammetric Engineering & Remote Sensing · doi:10.14358/pers.81.2.103 · Cited by 1,779
An Introduction to Statistical Methods and Data Analysis
Prybutok, V. R. (1989) · Technometrics · doi:10.1080/00401706.1989.10488572 · Cited by 1,499
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476
Gait Analysis: An Introduction
Whittle, M. W. (1986) · Cited by 920
Gait Analysis — An Introduction
CONDIE, D. N. (1992) · International Journal of Rehabilitation Research · doi:10.1097/00004356-199206000-00017 · Cited by 650
Cited by
Rear-foot, mid-foot and fore-foot motion during the stance phase of gait
Leardini, A., Benedetti, M. G., Berti, L., Bettinelli, D., Nativo, R., & Giannini, S. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.017 · Cited by 692
Carson, M. C., Harrington, M. E., Thompson, N., O’Connor, J. J., & Theologis, T. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00101-4 · Cited by 550
Foot kinematics and kinetics during adolescent gait
MacWilliams, B. A., Cowley, M., & Nicholson, D. E. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00103-0 · Cited by 319
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
An anatomically based protocol for the description of foot segment kinematics during gait
Leardini, A., Benedetti, M. G., Catani, F., Simoncini, L., & Giannini, S. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00008-x · Cited by 257
Metadata
- Authors
- Kidder, S. M., Abuzzahab, F. S., Harris, G. F., & Johnson, J. E.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1996-03
- Volume
- 4
- Issue
- 1
- Pages
- 25-32
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2148350822
- Cited by
- 291
- References
- 15
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A system for the analysis of foot and ankle kinematics during gait. https://app.cochat.ai/papers/10.1109/86.486054
- The paper
- Kidder, S. M., Abuzzahab, F. S., Harris, G. F., & Johnson, J. E. (1996). A system for the analysis of foot and ankle kinematics during gait. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.486054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.