CoChat

A low-cost instrumented glove for monitoring forces during object manipulation

Castro, M.C.F., Cliquet, A. · 1997 · IEEE Transactions on Rehabilitation Engineering
Cited by 75

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A rehabilitation program toward restoring upper limb movements based on neuromuscular electrical stimulation (NMES) depends on closed-loop control performance, which has been limited by the development of sensors for practical daily use. This work proposes a system to obtain force feedback. The system is comprised of a Lycra commercial glove with force sensing resistors (FSR's) attached to the distal phalanxes of the thumb, index and long fingers. After amplification and filtering, the signal is digitized through an analog-to-digital (A/D) converter. The polynomial fitting coefficients for the characteristic curves, obtained during the sensor calibration process, were inserted in the software thus enabling the reading of forces exerted during object manipulation. The system was applied to 30 normal subjects in order to verify its feasibility and to acquire knowledge of the normal hand function. Different ways of grasping have been detected according to the Force versus Time curve pattern and to the fingers predominantly used in grasping. Results have also shown the influence of parameters such as gender, age, hand size, and object weight in the normal function. The system did show efficacy. It was able to determine grasp forces during object manipulation for up to 73% of the studied sample. This is significant since a single glove was used in a wide range of subjects. For best results in medical applications, the glove should be tailored to the particular characteristics of an individual user.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.593280

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 75

Metadata

Authors
Castro, M. C. F., & Cliquet, A.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
1997-06
Volume
5
Issue
2
Pages
140-147
ISSN
  • 1063-6528 (ISSN-L)
  • 1558-0024
OpenAlex
W2099431085
Cited by
75
References
2
FWCI
1.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A low-cost instrumented glove for monitoring forces during object manipulation. https://app.cochat.ai/papers/10.1109/86.593280
The paper
Castro, M. C. F., & Cliquet, A. (1997). A low-cost instrumented glove for monitoring forces during object manipulation. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.593280

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.