The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Object Manipulation Improvements Due to Single Session Training Outweigh the Differences Among Stimulation Sites During Vibrotactile Feedback
Open accessAbstract
Most hand prostheses do not provide intentional haptic feedback about movement performance; thus users must rely almost completely on visual feedback. This paper focuses on understanding the effects of learning and different stimulation sites when vibrotactile stimulation is used as the intentional haptic feedback. Eighteen unimpaired individuals participated in this study with a robotic interface to manipulate a virtual object with visual and vibrotactile feedback at four body sites (finger, arm, neck, and foot) presented in a random order. All participants showed improvements in object manipulation performance with the addition of vibrotactile feedback. Specifically, performance showed a strong learning effect across time, with learning transferring across different sites of vibrotactile stimulation. The effects of learning over the experiment overshadowed the effects of different stimulation sites. The addition of a cognitive task slowed participants and increased the subjective difficulty. User preference ratings showed no difference in their preference among vibrotactile stimulation sites. These findings indicate that the stimulation site may not be as critical as ensuring adequate training with vibrotactile feedback during object manipulation. Future research to identify improvements in vibrotactile-based feedback parameters with amputees is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Interestingly, some sites might have an initial advantage in representing specific information, due to its naturalness; however, the advantage dissolves when users are given enough time to become familiar with less intuitive sites (Stepp & Matsuoka, 2011).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Stepp & Matsuoka, 2011
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age differences in short-term retention of rapidly changing information.
Kirchner, W. K. (1958) · Journal of Experimental Psychology · doi:10.1037/h0043688 · Cited by 1,798 · cited 1×
“This test involved listening to random 16 digit strings and responding verbally by identifying any numbers repeated with only one intervening number [35].”
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937 · cited 1×
“This frequency is in a region of maximal sensitivity of two of the four psychophysical channels: P and NP II, associated with Pacinian Corpuscle (PC) and Slowly Adapting (SA) II afferent fibers [33].”
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 2×
“The foremost attraction being that the noninvasive nature of this approach would allow for immediate wide-scale implementation among users of prosthetic hands [13], [14].”
Limb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States
DILLINGHAM, T. R., PEZZIN, L. E., & MACKENZIE, E. J. (2002) · Southern Medical Journal · doi:10.1097/00007611-200208000-00018 · Cited by 822 · cited 1×
“However, the most common causes of upper limb amputation are trauma and peripheral vascular disease, with the risk of amputation due to either cause increasing steadily with age [46].”
Vibrating insoles and balance control in elderly people
Priplata, A. A., Niemi, J. B., Harry, J. D., Lipsitz, L. A., & Collins, J. J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14470-4 · Cited by 572 · cited 1×
“Vibrotactile stimulators could be easily administered and hidden using insoles [29].”
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 1×
“2168981 have both been noted by users as top design priorities [1], [2].”
Flexible strategies for sensory integration during motor planning
Sober, S. J., & Sabes, P. N. (2005) · Nature Neuroscience · doi:10.1038/nn1427 · Cited by 480 · cited 1×
“, [36] and [37]), and that cross-modal transfer (CMT) can occur during”
Multisensory Integration during Motor Planning
Sober, S. J., & Sabes, P. N. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-18-06982.2003 · Cited by 430 · cited 1×
“, [36] and [37]), and that cross-modal transfer (CMT) can occur during”
Biomimetic tactile sensor array
Wettels, N., Santos, V. J., Johansson, R. S., & Loeb, G. E. (2008) · Advanced Robotics · doi:10.1163/156855308x314533 · Cited by 348 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6–12], with many groups successfully integrating these technologies into prosthetic hands, e.”
Upper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343 · cited 1×
“The addition of haptic feedback to prostheses may encourage self-attribution of the body part [3], and based on studies in unimpaired individuals, may aid in object manipulation (e.”
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
“Interestingly, some sites might have an initial advantage in representing specific information, due to its naturalness; however, the advantage dissolves when users are given enough time to become familiar with less intuitive sites (Stepp & Matsuoka, 2011).”
BackgroundHaptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“However, it may be that the location of skin stimulation is less important than other factors such as learning rates [55].”
BackgroundMarković, M., Schweisfurth, M. A., Engels, L. F., Bentz, T., Wüstefeld, D., Farina, D., & Dosen, S. S. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0371-1 · Cited by 148
“As demonstrated in previous studies, it seems that human subjects can flexibly integrate feedback delivered to different body locations [20, 42 – 44].”
BackgroundVirtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback
Jorgovanović, N., Dosen, S. S., Djozic, D. J., Krajoski, G., & Farina, D. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/120357 · Cited by 65
“, object manipulation rather than grasping) and for vibrotactile feedback [24], the training is very important for performance, even more than the actual stimulation setup [25].”
BackgroundRepeated Training with Augmentative Vibrotactile Feedback Increases Object Manipulation Performance
Stepp, C. E., An, Q., & Matsuoka, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032743 · Cited by 65
“neck, and foot), presented in a random order [25].”
BackgroundMethodResultSelf-citation
Metadata
- Authors
- Stepp, C. E., & Matsuoka, Y.
- Affiliations
- Boston University (US)
- University of Washington (US)
- ORCID
- Stepp, Cara E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-12
- Volume
- 19
- Issue
- 6
- Pages
- 677-685
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- PMC
- PMC3401581
- OpenAlex
- W2032949631
- Cited by
- 28
- References
- 49
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 4 · 2020: 2 · 2019: 3 · 2018: 2 · 2016: 1 · 2015: 5 · 2014: 3 · 2013: 2 · 2012: 4
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (T32HD007424)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- vibrotactile feedback, haptic feedback, prosthetic hand, object manipulation, stimulation site, learning effects, single-session training, robotic interface, virtual object manipulation, cognitive task interference, user preferences, amputees
- MeSH terms
- Adult, Arm, Cognition, Female, Fingers, Foot, Humans, Learning, Male, Motor Skills, Neck, Physical Stimulation, Psychomotor Performance, Robotics, Software, Touch, User-Computer Interface, Vibration, Feedback, Physiological, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Object Manipulation Improvements Due to Single Session Training Outweigh the Differences Among Stimulation Sites During Vibrotactile Feedback. https://app.cochat.ai/papers/10.1109/tnsre.2011.2168981
- The paper
- Stepp, C. E., & Matsuoka, Y. (2011). Object Manipulation Improvements Due to Single Session Training Outweigh the Differences Among Stimulation Sites During Vibrotactile Feedback. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2168981
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.