The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Brain-computer interface research at the Wadsworth Center
Abstract
Studies at the Wadsworth Center over the past 14 years have shown that people with or without motor disabilities can learn to control the amplitude of mu or beta rhythms in electroencephalographic (EEG) activity recorded from the scalp over sensorimotor cortex and can use that control to move a cursor on a computer screen in one or two dimensions. This EEG-based brain-computer interface (BCI) could provide a new augmentative communication technology for those who are totally paralyzed or have other severe motor impairments. Present research focuses on improving the speed and accuracy of BCI communication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Self-citationAmerican Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
Spatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936
Self-citationAmerican Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
Brain-Computer Interface—a new communication device for handicapped persons
Pfurtscheller, G., Flotzinger, D., & Kalcher, J. (1993) · Journal of Microcomputer Applications · doi:10.1006/jmca.1993.1030 · Cited by 502
Restoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · NeuroReport · doi:10.1097/00001756-199806010-00007 · Cited by 475
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
Self-citationThe brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
EEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396
Self-citationBiofeedback of slow cortical potentials. I
Elbert, T., Rockstroh, B., Lutzenberger, W., & Birbaumer, N. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90265-5 · Cited by 197
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Kalcher, J., Flotzinger, D., Neuper, C., Gölly, S., & Pfurtscheller, G. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520010 · Cited by 168
McFarland, D. J., Lefkowicz, A. T., & Wolpaw, J. R. (1997) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200585 · Cited by 167
Self-citationEEG-based communication: prospects and problems
Vaughan, T. M., Wolpaw, J. R., & Donchin, E. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547945 · Cited by 164
Self-citationKennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Applications of cortical signals to neuroprosthetic control: a critical review
Lauer, R. T., Peckham, P. H., Kilgore, K. L., & Heetderks, W. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847817 · Cited by 120
EEG-based control of a hand grasp neuroprosthesis
Lauer, R. T., Peckham, P. H., & Kilgore, K. L. (1999) · Neuroreport · doi:10.1097/00001756-199906030-00026 · Cited by 108
Answering questions with an electroencephalogram-based brain-computer interface
Miner, L. A., McFarland, D. J., & Wolpaw, J. R. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90165-4 · Cited by 85
Self-citationTiming of EEG-Based Cursor Control
Wolpaw, J. R., Flotzinger, D., Pfurtscheller, G., & McFarland, D. J. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199711000-00010 · Cited by 57
Self-citationSelf-regulation of slow cortical potentials in completely paralyzed human patients
Kuebler, A., Kotchoubey, B., Salzmann, H.-P., Ghanayim, N., Perelmouter, J., Hömberg, V., & Birbaumer, N. (1998) · Neuroscience Letters · doi:10.1016/s0304-3940(98)00570-9 · Cited by 46
Ramoser, H., Wolpaw, J. R., & Pfurtscheller, G. (1997) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1997.42.9.226 · Cited by 46
Self-citationEEG-based communication: analysis of concurrent EMG activity
Vaughan, T. M., Miner, L. A., McFarland, D. J., & Wolpaw, J. R. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00107-2 · Cited by 39
Self-citation
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationBrain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Self-citationBrain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080
Metadata
- Authors
- Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 2000-06
- Volume
- 8
- Issue
- 2
- Pages
- 222-226
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2149094129
- Cited by
- 440
- References
- 23
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.