Reducing motion artifact in wearable biosensors using mems accelerometers for active noise cancellation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents an active noise cancellation method using a MEMS accelerometer that recovers wearable sensor signals corrupted by body motion. The method is developed for a finger ring photoplethysmograph (PPG) sensor, the signal of which is susceptive to the hand motion of the wearer. A MEMS accelerometer (ACC) imbedded in the PPG sensor detects the hand acceleration, and is used for recovering the corrupted PPG signal, based upon two different methods of modeling the process of signal corruption. The correlation between the acceleration and the distorted PPG signal is analyzed, and a low-order FIR model relating the signal distortion to the hand acceleration is obtained. The model parameters are identified in real time with a recursive least square method. Experiments show that the active noise cancellation method can recover ring PPG sensor signals corrupted with 2G of acceleration in the longitudinal direction of the digital artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“This is essentially Widrow’s Active Noise Cancellation (ANC) [ 8 ].”
BackgroundMobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Self-citationArtifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235 · cited 1×
“In the following, the method will be developed in the context of reducing motion artifact in a photoplethysmograph (PPG) ring sensor [5].”
MethodSelf-citation
Cited by
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter
Ram, M. R., Madhav, K. V., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2175832 · Cited by 345
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Wearable Sensing Technology Applications in Construction Safety and Health
Ahn, C. R., Lee, S., Sun, C., Jebelli, H., Yang, K., & Choi, B. (2019) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001708 · Cited by 290
Vo, D.-K., & Trinh, K. T. L. (2024) · Biosensors · doi:10.3390/bios14110560 · Cited by 231
“Sensors implanted within the body, closer to all biological systems, would be able to transmit real-time information, while wearables take external factors and physical activity into consideration, thus building a total picture of a person’s health (Figure 8) [154].”
Metadata
- Authors
- Gibbs, P., & Asada, H. H.
- Venue
- Proceedings of the 2005, American Control Conference, 2005.
- Publisher
- IEEE
- Published
- 2005-08-10
- Pages
- 1581-1586
- ISSN
- 0743-1619 (ISSN-L)
- OpenAlex
- W2123601657
- Cited by
- 62
- References
- 3
- FWCI
- 2.33
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reducing motion artifact in wearable biosensors using mems accelerometers for active noise cancellation. https://app.cochat.ai/papers/10.1109/acc.2005.1470193
- The paper
- Gibbs, P., & Asada, H. H. (2005). Reducing motion artifact in wearable biosensors using mems accelerometers for active noise cancellation. Proceedings of the 2005, American Control Conference, 2005. https://doi.org/10.1109/acc.2005.1470193
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.