The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Load Frequency Control of an Isolated Micro Grid Using Fuzzy Adaptive Model Predictive Control
Open accessAbstract
This paper presents a fuzzy adaptive model predictive approach for load frequency control of an isolated micro grid. A generalized state space model of a typical isolated micro grid having controllable and uncontrollable generating power sources is derived, and the same has been utilized to predict the future output and control inputs for the micro grid frequency control. A centralized model predictive control (MPC) is implemented with a single input multi-output system model based on the controllable distributed energy resources in the micro grid. The parameter-driven MPC is made adaptable by dynamically adjusting its parameter Rw using fuzzy controller. The proposed fuzzy MPC employs a rule-based fuzzy controller to fuzzify the tuning parameter Rw present in the cost function of MPC, which plays an important role in minimizing the frequency deviation in the system. The closed loop system response obtained by the proposed fuzzy MPC has been found faster and adaptable for different scenarios in the system. The effectiveness has been evaluated with performance index integral time square error (ITSE) value and has been compared with MPC with constant tuning parameter value also with the proportional-integral controller response. Thus, the efficacy of using proposed fuzzy MPC in secondary load frequency control has been validated thereof.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 1×
“Even though there are several works on control and management of microgrid in different perspective over the past two decades [1], [2], the regulation of frequency and voltage within specified nominal values in isolated microgrid operation is really an important aspect for reliable system operation [3] and one that ha…”
Background
Cited by
Model predictive control of microgrids – An overview
Hu, J., Shan, Y., Guerrero, J. M., Ioinovici, A., Chan, K. W., & Rodriguez, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110422 · Cited by 451
Mohammadikia, R., & Tavakoli‐Kakhki, M. (2025) · Asian Journal of Control · doi:10.1002/asjc.3538 · Cited by 1
“An adaptive fuzzy model predictive load frequency controller was presented for an interconnected power system, where the parameters of model predictive controller are dynamically adjusted using fuzzy control [57].”
Metadata
- Authors
- Kayalvizhi, S., & Vinod Kumar, D. M.
- Venue
- IEEE Access
- Published
- 2017
- Volume
- 5
- Pages
- 16241-16251
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2748609964
- Cited by
- 175
- References
- 2
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Load Frequency Control of an Isolated Micro Grid Using Fuzzy Adaptive Model Predictive Control. https://app.cochat.ai/papers/10.1109/access.2017.2735545
- The paper
- Kayalvizhi, S., & Vinod Kumar, D. M. (2017). Load Frequency Control of an Isolated Micro Grid Using Fuzzy Adaptive Model Predictive Control. IEEE Access. https://doi.org/10.1109/access.2017.2735545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.