The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
ECG Signal Preprocessing and SVM Classifier-Based Abnormality Detection in Remote Healthcare Applications
Open accessAbstract
Medical expert systems are part of the portable and smart healthcare monitoring devices used in day-to-day life. Arrhythmic beat classification is mainly used in electrocardiogram (ECG) abnormality detection for identifying heart related problems. In this paper, ECG signal preprocessing and support vector machine-based arrhythmic beat classification are performed to categorize into normal and abnormal subjects. In ECG signal preprocessing, a delayed error normalized LMS adaptive filter is used to achieve high speed and low latency design with less computational elements. Since the signal processing technique is developed for remote healthcare systems, white noise removal is mainly focused. Discrete wavelet transform is applied on the preprocessed signal for HRV feature extraction and machine learning techniques are used for performing arrhythmic beat classification. In this paper, SVM classifier and other popular classifiers have been used on noise removed feature extracted signal for beat classification. Results indicate that the performance of SVM classifier is better than other machine learning-based classifiers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720 · cited 1×
“Frequency domain analysis of HRVprovides vital information about cardiovascular control which is crucial in the identification of sympathetic and parasympathetic activities [18].”
BackgroundSassi, R., Cerutti, S., Lombardi, F., Malik, M., Huikuri, H. V., Peng, C.-K., Schmidt, G., Yamamoto, Y., Reviewers:, D., Gorenek, B., et al. (2015) · Europace · doi:10.1093/europace/euv015 · Cited by 727
A patient-adaptable ECG beat classifier using a mixture of experts approach
Hu, Y. H., Palreddy, S., & Tompkins, W. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623058 · Cited by 614
Support Vector Machine-Based Expert System for Reliable Heartbeat Recognition
Osowski, S., Hoai, L. T., & Markiewicz, T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824138 · Cited by 536
QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases
Saini, I., Singh, D., & Khosla, A. (2013) · Journal of Advanced Research · doi:10.1016/j.jare.2012.05.007 · Cited by 346
Poungponsri, S., & Yu, X.-H. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.02.010 · Cited by 266
An arrhythmia classification system based on the RR-interval signal
Tsipouras, M. G., Fotiadis, D. I., & Sideris, D. (2005) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2004.03.007 · Cited by 231
ECG Signal Processing, Classification and Interpretation
Gacek, A., & Witold Pedrycz, C. (2011) · Springer eBooks · doi:10.1007/978-0-85729-868-3 · Cited by 229
Cardiac arrhythmia classification using statistical and mixture modeling features of ECG signals
Ghorbani Afkhami, R., Azarnia, G., & Tinati, M. A. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2015.11.018 · Cited by 208
Cubbon, R. M., Adams, B., Rajwani, A., Mercer, B. N., Patel, P. A., Gherardi, G., Gale, C. P., Batin, P. D., Ajjan, R., Kearney, L., et al. (2013) · Diabetes and Vascular Disease Research · doi:10.1177/1479164112471064 · Cited by 167
Chawla, M. P. S. (2010) · Applied Soft Computing · doi:10.1016/j.asoc.2010.08.001 · Cited by 131
Low-complexity R-peak detection for ambulatory fetal monitoring
Rooijakkers, M. J., Rabotti, C., Oei, S. G., & Mischi, M. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/7/1135 · Cited by 79
Classification of heart diseases from ECG signals using wavelet transform and kNN classifier
Saini, R., Bindal, N., & Bansal, P. (2015) · International Conference on Computing, Communication and Automation · doi:10.1109/ccaa.2015.7148561 · Cited by 58
Petković, D., Ćojbašić, Ž., & Lukić, S. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.01.055 · Cited by 57
R wave detection using Coiflets wavelets
Elgendi, M., Jonkman, M., & Boer, F. D. (2009) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2009.4967756 · Cited by 47
Hashim, A., Ooi, C. Y., Bakhteri, R., & Hau, Y. W. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047494 · Cited by 8
Cited by
Rai, R., & Sahu, C. K. (2020) · IEEE Access · doi:10.1109/access.2020.2987324 · Cited by 315
Metadata
- Authors
- Venkatesan, C., Karthigaikumar, P., Paul, A., Satheeskumaran, S., & Kumar, R.
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 9767-9773
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2793933216
- Cited by
- 286
- References
- 16
- FWCI
- 18.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.