The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases
Open accessAbstract
The performance of computer aided ECG analysis depends on the precise and accurate delineation of QRS-complexes. This paper presents an application of K-Nearest Neighbor (KNN) algorithm as a classifier for detection of QRS-complex in ECG. The proposed algorithm is evaluated on two manually annotated standard databases such as CSE and MIT-BIH Arrhythmia database. In this work, a digital band-pass filter is used to reduce false detection caused by interference present in ECG signal and further gradient of the signal is used as a feature for QRS-detection. In addition the accuracy of KNN based classifier is largely dependent on the value of K and type of distance metric. The value of K = 3 and Euclidean distance metric has been proposed for the KNN classifier, using fivefold cross-validation. The detection rates of 99.89% and 99.81% are achieved for CSE and MIT-BIH databases respectively. The QRS detector obtained a sensitivity Se = 99.86% and specificity Sp = 99.86% for CSE database, and Se = 99.81% and Sp = 99.86% for MIT-BIH Arrhythmia database. A comparison is also made between proposed algorithm and other published work using CSE and MIT-BIH Arrhythmia databases. These results clearly establishes KNN algorithm for reliable and accurate QRS-detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
The Massachusetts Institute of Technology
Endowed, S. C. F. (1999) · Anthropology News · doi:10.1111/an.1999.40.2.6 · Cited by 3,135
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
The principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Real time electrocardiogram QRS detection using combined adaptive threshold
Christov, I. I. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-28 · Cited by 464
Neural-network-based adaptive matched filtering for QRS detection
Xue, Q., Hu, Y. H., & Tompkins, W. J. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126604 · Cited by 423
A novel method for detecting R-peaks in electrocardiogram (ECG) signal
Manikandan, M. S., & Soman, K. P. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.03.004 · Cited by 393
Cited by
Artificial Intelligence in Precision Cardiovascular Medicine
Krittanawong, C., Zhang, H., Wang, Z., Aydar, M., & Kitai, T. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.571 · Cited by 1,120
Venkatesan, C., Karthigaikumar, P., Paul, A., Satheeskumaran, S., & Kumar, R. (2018) · IEEE Access · doi:10.1109/access.2018.2794346 · Cited by 286
A novel k NN algorithm with data-driven k parameter computation
Zhang, S., Cheng, D., Deng, Z., Zong, M., & Deng, X. (2018) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.09.036 · Cited by 278
Niu, G., Yang, P., Zheng, Y., Cai, X., & Qin, H. (2021) · Water Resources Research · doi:10.1029/2020wr029121 · Cited by 19
Metadata
- Authors
- Saini, I., Singh, D., & Khosla, A.
- Venue
- Journal of Advanced Research
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 4
- Issue
- 4
- Pages
- 331-344
- ISSN
- 2090-1224 (ISSN-L)
- 2090-1232
- OpenAlex
- W1973163442
- Cited by
- 346
- References
- 26
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases. https://app.cochat.ai/papers/10.1016/j.jare.2012.05.007
- The paper
- Saini, I., Singh, D., & Khosla, A. (2013). QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases. Journal of Advanced Research. https://doi.org/10.1016/j.jare.2012.05.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.