The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Data-Driven Monitoring and Safety Control of Industrial Cyber-Physical Systems: Basics and Beyond
Open accessAbstract
Industrial cyber-physical systems (ICPSs) are the backbones of Industry 4.0 and as such, have become a core transdisciplinary area of research, both in industry and academia. New challenges brought about by the growing scale and complexity of systems, insufficient information exchange, and the exploitation of knowledge available have started threatening the overall system safety and stability. This work is motivated by these challenges and the strategic and practical demands of developing ICPSs for safety critical systems such as the intelligent factory and the smart grid. It investigates the current status of research in ICPS monitoring and control, and reviews the recent advances in monitoring, fault diagnosis, and control approaches based on data-driven realization, which can take full advantage of the abundant data available from past observations and those collected online in realtime. The practical requirements in the typical ICPS applications are summarized as the major issues to be addressed for the monitoring and the safety control tasks. The key challenges and the research directions are proposed as references to the future work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Secure Estimation and Control for Cyber-Physical Systems Under Adversarial Attacks
Fawzi, H., Tabuada, P., & Diggavi, S. (2014) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2014.2303233 · Cited by 1,278
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
Automatic License Plate Recognition (ALPR): A State-of-the-Art Review
Du, S., Ibrahim, M., Shehata, M., & Badawy, W. (2013) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2012.2203741 · Cited by 835
Data-driven Design of Fault Diagnosis and Fault-tolerant Control Systems
Ding, S. X. (2014) · Advances in Industrial Control · doi:10.1007/978-1-4471-6410-4 · Cited by 669
Improved PLS Focused on Key-Performance-Indicator-Related Fault Diagnosis
Yin, S., Zhu, X., & Kaynak, O. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345331 · Cited by 537
Self-citationEnergy Management and Control System for Laboratory Scale Microgrid Based Wind-PV-Battery
Merabet, A., Tawfique Ahmed, K., Ibrahim, H., Beguenane, R., & Ghias, A. M. Y. M. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2587828 · Cited by 433
Sajid, A., Abbas, H., & Saleem, K. (2016) · IEEE Access · doi:10.1109/access.2016.2549047 · Cited by 401
Gao, Z., Liu, X., & Chen, M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2497201 · Cited by 380
Design of Smart Sensors for Real-Time Water Quality Monitoring
Cloete, N. A., Malekian, R., & Nair, L. (2016) · IEEE Access · doi:10.1109/access.2016.2592958 · Cited by 318
Subspace method aided data-driven design of fault detection and isolation systems
Ding, S. X., Zhang, P., Naik, A., Ding, E. L., & Huang, B. (2009) · Journal of Process Control · doi:10.1016/j.jprocont.2009.07.005 · Cited by 312
Cited by
Data-Driven Methods for Predictive Maintenance of Industrial Equipment: A Survey
Zhang, W., Yang, D., & Wang, H. (2019) · IEEE Systems Journal · doi:10.1109/jsyst.2019.2905565 · Cited by 732
A Review on Soft Sensors for Monitoring, Control, and Optimization of Industrial Processes
Jiang, Y., Yin, S., Dong, J., & Kaynak, O. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3033153 · Cited by 667
Self-citationA review on fault detection and diagnosis techniques: basics and beyond
Abid, A., Khan, M. T., & Iqbal, J. (2021) · Artificial Intelligence Review · doi:10.1007/s10462-020-09934-2 · Cited by 436
Industrial applications of digital twins
Jiang, Y., Yin, S., Li, K., Luo, H., & Kaynak, O. (2021) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2020.0360 · Cited by 398
Self-citationRemaining Useful Life Prediction Using a Novel Feature-Attention-Based End-to-End Approach
Liu, H., Liu, Z., Jia, W., & Lin, X. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2983760 · Cited by 324
Metadata
- Authors
- Jiang, Y., Yin, S., & Kaynak, O.
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 47374-47384
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2888609085
- Cited by
- 263
- References
- 46
- FWCI
- 23.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Data-Driven Monitoring and Safety Control of Industrial Cyber-Physical Systems: Basics and Beyond. https://app.cochat.ai/papers/10.1109/access.2018.2866403
- The paper
- Jiang, Y., Yin, S., & Kaynak, O. (2018). Data-Driven Monitoring and Safety Control of Industrial Cyber-Physical Systems: Basics and Beyond. IEEE Access. https://doi.org/10.1109/access.2018.2866403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.