The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar
Open accessAbstract
Electromagnetic radars have been shown potentially to be used for remote sensing of biosignals in a more comfortable and easier way than wearable and contact devices. While there is an increasing interest in using radars for health monitoring, their performance has not been tested and reported either in practical scenarios or with acceptable low errors. Therefore, we use a frequency modulated continuous wave (FMCW) radar operating at 77 GHz in a bedroom environment to extract the respiration and heart rates of a patient, who is used to lying down on the bed. Indeed, the proposed signal processing contains advanced phase unwrapping manipulation, which is unique. In addition, the results are compared with a reliable reference sensor. Our results show that the correlations between the reference sensor and the radar estimates are in 94% and 80% for breathing and heart rates, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2008) · Wiley eBooks · doi:10.1002/9780470294154 · Cited by 1,378
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities
Villar, R., Beltrame, T., & Hughson, R. L. (2015) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2015-0140 · Cited by 178
Impact of Frequency Ramp Nonlinearity, Phase Noise, and SNR on FMCW Radar Accuracy
Ayhan, S., Scherr, S., Bhutani, A., Fischbach, B., Pauli, M., & Zwick, T. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2599165 · Cited by 147
FMCW radar for life-sign detection
Anitori, L., de Jong, A., & Nennie, F. (2009) · IEEE Radar Conference (RadarConf) · doi:10.1109/radar.2009.4976934 · Cited by 108
Physical Working Principles of Medical Radar
Aardal, Ø., Paichard, Y., Brovoll, S., Berger, T., Lande, T. S., & Hamran, S.-E. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2228263 · Cited by 97
Vespe, M., Jones, G., & Baker, C. (2009) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.930412 · Cited by 77
Zhu, F., Wang, K., & Wu, K. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2869591 · Cited by 52
ApneaRadar: A 24GHz Radar-Based Contactless Sleep Apnea Detection System
Du, N., Liu, K., Ge, L., & Zhang, J. (2017) · International Conference on Frontiers of Sensors Technologies (ICFST) · doi:10.1109/icfst.2017.8210539 · Cited by 29
Cited by
Artificial Intelligence in Medical Sensors for Clinical Decisions
Haick, H., & Tang, N. (2021) · ACS Nano · doi:10.1021/acsnano.1c00085 · Cited by 231
Metadata
- Authors
- Alizadeh, M., Shaker, G., Almeida, J. C. M. D., Morita, P. P., & Safavi-Naeini, S.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 54958-54968
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2941074488
- Cited by
- 535
- References
- 10
- FWCI
- 16.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.