CoChat

Multi-View Feature Fusion Based Four Views Model for Mammogram Classification Using Convolutional Neural Network

Open access
Nasir Khan, Hasan, Shahid, Ahmad Raza, Raza, Basit, Dar, Amir Hanif, Alquhayz, Hani · 2019 · IEEE Access
Cited by 177

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Breast cancer is the second most common cause of cancer-related deaths among women. Early detection leads to better prognosis and saves lives. The 5-year survival rate of breast cancer is 99% if it is located only in breast. Conventional computer-aided diagnosis (CADx) systems for breast cancer use the single view information of mammograms to assist the radiologists. More recent work has focused on more than one views. Existing multi-view based CADx systems normally employ only two views namely Cranio-Caudal (CC) and Medio-Lateral-Oblique (MLO). The information fusion of the two views proved the effectiveness of the system for mammogram classification which cannot be achieved by single view information. However, combining the information of four views of mammograms increases the performance of classification. In this study, we propose Multi-View Feature Fusion (MVFF) based CADx system using feature fusion technique of four views for classification of mammogram. The complete CADx tool contains three stages, the first stage have the ability to classify mammogram into abnormal or normal, second stage is about classification of mass or calcification and in the final stage classification of malignant or benign classification is performed. Convolutional Neural Network (CNN) based feature extraction models operate on each view separately. These extracted features were fused into one final layer for ultimate prediction. Our proposed system is trained on four views of mammograms, after data augmentation. We performed our experiments on publicly available datasets such as CBIS-DDSM (Curated Breast Imaging Subset of DDSM) and mini-MIAS database of mammograms. In comparison with literature the MVFF based system is performed better than a single view-based system for mammogram classification. We have achieved area under ROC curve (AUC) of 0.932 for mass and calcification and 0.84 for malignant and benign, which is higher than all single-view based systems. The value of AUC for normal and abnormal classification is 0.93.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2019.2953318

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Metadata

Authors
Nasir Khan, H., Shahid, A. R., Raza, B., Dar, A. H., & Alquhayz, H.
Venue
IEEE Access
Published
2019
Volume
7
Pages
165724-165733
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2984544647
Cited by
177
References
7
FWCI
7.71
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multi-View Feature Fusion Based Four Views Model for Mammogram Classification Using Convolutional Neural Network. https://app.cochat.ai/papers/10.1109/access.2019.2953318
The paper
Nasir Khan, H., Shahid, A. R., Raza, B., Dar, A. H., & Alquhayz, H. (2019). Multi-View Feature Fusion Based Four Views Model for Mammogram Classification Using Convolutional Neural Network. IEEE Access. https://doi.org/10.1109/access.2019.2953318

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.