CoChat

Motor Imagery EEG Signals Decoding by Multivariate Empirical Wavelet Transform-Based Framework for Robust Brain–Computer Interfaces

Open access
Sadiq, Muhammad Tariq, Yu, Xiaojun, Yuan, Zhaohui, Zeming, Fan, Rehman, Ateeq Ur, Ullah, Inam, Li, Guoqi, Xiao, Gaoxi · 2019 · IEEE Access
Cited by 194

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The robustness and computational load are the key challenges in motor imagery (MI) based on electroencephalography (EEG) signals to decode for the development of practical brain-computer interface (BCI) systems. In this study, we propose a robust and simple automated multivariate empirical wavelet transform (MEWT) algorithm for the decoding of different MI tasks. The main contributions of this study are four-fold. First, the multiscale principal component analysis method is utilized in the preprocessing module to obtain robustness against noise. Second, a novel automated channel selection strategy is proposed and then is further verified with comprehensive comparisons among three different strategies for decoding channel combination selection. Third, a sub-band alignment method by utilizing MEWT is adopted to obtain joint instantaneous amplitude and frequency components for the first time in MI applications. Four, a robust correlation-based feature selection strategy is applied to largely reduce the system complexity and computational load. Extensive experiments for subject-specific and subject independent cases are conducted with the three-benchmark datasets from BCI competition III to evaluate the performances of the proposed method by employing typical machine-learning classifiers. For subject-specific case, experimental results show that an average sensitivity, specificity and classification accuracy of 98% was achieved by employing multilayer perceptron neural networks, logistic model tree and least-square support vector machine (LS-SVM) classifiers, respectively for three datasets, resulting in an improvement of upto 23.50% in classification accuracy as compared with other existing method. While an average sensitivity, specificity and classification accuracy of 93%, 92.1% and 91.4% was achieved for subject independent case by employing LS-SVM classifier for all datasets with an increase of up to 18.14% relative to other existing methods. Results also show that our proposed algorithm provides a classification accuracy of 100% for subjects with small training size in subject-specific case, and for subject independent case by employing a single source subject. Such satisfactory results demonstrate the great potential of the proposed MEWT algorithm for practical MI EEG signals classification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2019.2956018

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 194

Metadata

Authors
Sadiq, M. T., Yu, X., Yuan, Z., Zeming, F., Rehman, A. U., Ullah, I., Li, G., & Xiao, G.
Venue
IEEE Access
Published
2019
Volume
7
Pages
171431-171451
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2990331389
Cited by
194
References
6
FWCI
11.63
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motor Imagery EEG Signals Decoding by Multivariate Empirical Wavelet Transform-Based Framework for Robust Brain–Computer Interfaces. https://app.cochat.ai/papers/10.1109/access.2019.2956018
The paper
Sadiq, M. T., Yu, X., Yuan, Z., Zeming, F., Rehman, A. U., Ullah, I., Li, G., & Xiao, G. (2019). Motor Imagery EEG Signals Decoding by Multivariate Empirical Wavelet Transform-Based Framework for Robust Brain–Computer Interfaces. IEEE Access. https://doi.org/10.1109/access.2019.2956018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.