Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
A microgrid (MG) is a small-scale power system with a cluster of loads and distributed generators operating together through energy management software and devices that act as a single controllable entity with respect to the grid. MG has become a key research element in smart grid and distribution power systems. MG mainly contains different renewable energy sources (RESs) that use various technological advancements, such as power electronics-based technologies. However, it has an unstable output, thereby causing different types of power quality (PQ) events. As a result, standards and mitigation methods have been developed in recent years. To mitigate PQ issues due to MG integration, various methods and standards have been proposed over the last years. Although these individual methods are well documented, a comparative overview had not been introduced so far. Thus, this study aims to fill the gap by reviewing and comparing the prior-art PQ issues, solutions, and standards in MGs. We compare the main issues related to voltage sag, voltage swell, voltage and current harmonics, system unbalances, and fluctuations to ensure high-quality MG output power. The new technologies associated with MGs generate harmonics emission in the range of 2-150 kHz, thereby causing a new phenomenon, namely, supraharmonics (SH) emission, which is not sufficiently covered in the literature. Therefore, the characteristics, causes, consequences, and measurements of SH are highlighted and analyzed. The mitigation strategies, control, and devices of PQ issues are also discussed. Moreover, a comparison is conducted between the most popular devices used to mitigate the PQ issues in MG in terms of cost, rating, and different aspects of performance. This review study can strengthen the efforts toward the mitigation and standards development of PQ issues in MG applications, especially SH. Finally, some recommendations and suggestions to improve PQ of MG, including SH, are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Quality Enhancement Using Custom Power Devices
Ghosh, A., & Ledwich, G. (2002) · Springer eBooks · doi:10.1007/978-1-4615-1153-3 · Cited by 1,365
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245 · cited 1×
“In such a case, an electronic power interface is required for energy conversion to regulate the local power and voltage [48].”
BackgroundMicrogrids energy management systems: A critical review on methods, solutions, and prospects
Zia, M. F., Elbouchikhi, E., & Benbouzid, M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.103 · Cited by 1,005 · cited 1×
“Others reviewed various MG applications, including MG stability [39], MG energy management [40], planning and operation of MG [41], MG protection [42], and control strategies of MG systems [43].”
BackgroundAC and DC technology in microgrids: A review
Planas, E., Andreu, J., Gárate, J. I., Martínez de Alegría, I., & Ibarra, E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.11.067 · Cited by 500 · cited 1×
“Commonly, the three-phase AC bus is utilized as PCC and in between the main power grid and MG, a fast switch is implemented as a cut-off point [51].”
MethodSavaghebi, M., Jalilian, A., Vasquez, J. C., & Guerrero, J. M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2181432 · Cited by 475
AC Versus DC Microgrid Planning
Lotfi, H., & Khodaei, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2457910 · Cited by 469 · cited 2×
“9 illustrates the single line diagram of a hybrid AC/DC MG [54], [56].”
BackgroundPower Quality in Power Systems and Electrical Machines
(2015) · Elsevier eBooks · doi:10.1016/c2013-0-18758-2 · Cited by 455
Control Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454 · cited 1×
“Others reviewed various MG applications, including MG stability [39], MG energy management [40], planning and operation of MG [41], MG protection [42], and control strategies of MG systems [43].”
BackgroundSelf-citationAl-Shetwi, A. Q., Hannan, M. A., Jern, K. P., Mansur, M., & Mahlia, T. M. I. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.119831 · Cited by 442 · cited 3×
“Table 5 shows the limits of voltage and time duration allowed according to different countries’ GC and regulations in case of sag and swell events [8].”
BackgroundSelf-citationPotential-Function Based Control of a Microgrid in Islanded and Grid-Connected Modes
Mehrizi-Sani, A., & Iravani, R. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2045773 · Cited by 428 · cited 1×
“Thus, PQ issues need more investigation in this case [57].”
Background
Cited by
Al-Shetwi, A. Q. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.153645 · Cited by 703
Self-citationGrid integration impacts and control strategies for renewable based microgrid
Fazal, S., Enamul Haque, M., Taufiqul Arif, M., Gargoom, A., & Oo, A. M. T. (2023) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2023.103069 · Cited by 74
Stochastic Approach for Increasing the PV Hosting Capacity of a Low-Voltage Distribution Network
Bendík, J., Cenký, M., Cintula, B., Beláń, A., Eleschová, Ž., & Janiga, P. (2022) · Processes · doi:10.3390/pr11010009 · Cited by 26
Metadata
- Authors
- Alkahtani, A. A., Alfalahi, S. T. Y., Athamneh, A. A., Al-Shetwi, A. Q., Mansor, M. B., Hannan, M. A., & Agelidis, V. G.
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 127104-127122
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3041059612
- Cited by
- 195
- References
- 52
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.