Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
A microgrid (MG) is a small-scale power system with a cluster of loads and distributed generators operating together through energy management software and devices that act as a single controllable entity with respect to the grid. MG has become a key research element in smart grid and distribution power systems. MG mainly contains different renewable energy sources (RESs) that use various technological advancements, such as power electronics-based technologies. However, it has an unstable output, thereby causing different types of power quality (PQ) events. As a result, standards and mitigation methods have been developed in recent years. To mitigate PQ issues due to MG integration, various methods and standards have been proposed over the last years. Although these individual methods are well documented, a comparative overview had not been introduced so far. Thus, this study aims to fill the gap by reviewing and comparing the prior-art PQ issues, solutions, and standards in MGs. We compare the main issues related to voltage sag, voltage swell, voltage and current harmonics, system unbalances, and fluctuations to ensure high-quality MG output power. The new technologies associated with MGs generate harmonics emission in the range of 2-150 kHz, thereby causing a new phenomenon, namely, supraharmonics (SH) emission, which is not sufficiently covered in the literature. Therefore, the characteristics, causes, consequences, and measurements of SH are highlighted and analyzed. The mitigation strategies, control, and devices of PQ issues are also discussed. Moreover, a comparison is conducted between the most popular devices used to mitigate the PQ issues in MG in terms of cost, rating, and different aspects of performance. This review study can strengthen the efforts toward the mitigation and standards development of PQ issues in MG applications, especially SH. Finally, some recommendations and suggestions to improve PQ of MG, including SH, are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Quality Enhancement Using Custom Power Devices
Ghosh, A., & Ledwich, G. (2002) · Springer eBooks · doi:10.1007/978-1-4615-1153-3 · Cited by 1,365
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245 · cited 1×
“In such a case, an electronic power interface is required for energy conversion to regulate the local power and voltage [48].”
BackgroundMicrogrids energy management systems: A critical review on methods, solutions, and prospects
Zia, M. F., Elbouchikhi, E., & Benbouzid, M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.103 · Cited by 1,005 · cited 1×
“Others reviewed various MG applications, including MG stability [39], MG energy management [40], planning and operation of MG [41], MG protection [42], and control strategies of MG systems [43].”
BackgroundAC and DC technology in microgrids: A review
Planas, E., Andreu, J., Gárate, J. I., Martínez de Alegría, I., & Ibarra, E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.11.067 · Cited by 500 · cited 1×
“Commonly, the three-phase AC bus is utilized as PCC and in between the main power grid and MG, a fast switch is implemented as a cut-off point [51].”
MethodSavaghebi, M., Jalilian, A., Vasquez, J. C., & Guerrero, J. M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2181432 · Cited by 475
AC Versus DC Microgrid Planning
Lotfi, H., & Khodaei, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2457910 · Cited by 469 · cited 2×
“9 illustrates the single line diagram of a hybrid AC/DC MG [54], [56].”
BackgroundPower Quality in Power Systems and Electrical Machines
(2015) · Elsevier eBooks · doi:10.1016/c2013-0-18758-2 · Cited by 455
Control Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454 · cited 1×
“Others reviewed various MG applications, including MG stability [39], MG energy management [40], planning and operation of MG [41], MG protection [42], and control strategies of MG systems [43].”
BackgroundSelf-citationAl-Shetwi, A. Q., Hannan, M. A., Jern, K. P., Mansur, M., & Mahlia, T. M. I. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.119831 · Cited by 442 · cited 3×
“Table 5 shows the limits of voltage and time duration allowed according to different countries’ GC and regulations in case of sag and swell events [8].”
BackgroundSelf-citationPotential-Function Based Control of a Microgrid in Islanded and Grid-Connected Modes
Mehrizi-Sani, A., & Iravani, R. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2045773 · Cited by 428 · cited 1×
“Thus, PQ issues need more investigation in this case [57].”
BackgroundLow Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426 · cited 2×
“The authors in [117] compared the effectiveness of SVC and STATCOM in addressing the sag event and found that the STATCOM contributes more to the transient margin compared with the SVC.”
BackgroundResultMicrogrid stability: Classification and a review
Shuai, Z., Sun, Y., Shen, Z. J., Tian, W., Tu, C., Li, Y., & Yin, X. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.201 · Cited by 368 · cited 1×
“Others reviewed various MG applications, including MG stability [39], MG energy management [40], planning and operation of MG [41], MG protection [42], and control strategies of MG systems [43].”
BackgroundReview of harmonic analysis, modeling and mitigation techniques
Kalair, A. R., Abas, N., Kalair, A. R., Saleem, Z., & Khan, N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.121 · Cited by 347 · cited 1×
“Smart power grids have made SH emissions relevant [106].”
BackgroundGandoman, F. H., Ahmadi, A., Sharaf, A. M., Siano, P., Pou, J., Hredzak, B., & Agelidis, V. G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.062 · Cited by 345 · cited 1×
“Furthermore, many studies reviewed the PQ for conventional power systems, such as [37], [38].”
BackgroundSelf-citationMicrogrid testbeds around the world: State of art
Hossain, E., Kabalci, E., Bayindir, R., & Perez, R. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.012 · Cited by 331 · cited 1×
“Two international standards exist, namely, IEC and IEEE, and different countries with high RES installation, such as Germany and the US, have improved their GCs with new standards [22], [62]–[67].”
BackgroundGeneral aspects, hierarchical controls and droop methods in microgrids: A review
Planas, E., Gil-de-Muro, A., Andreu, J., Kortabarria, I., & Martínez de Alegría, I. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.09.032 · Cited by 318 · cited 1×
“In 1882, Thomas Edison installed the first electric power system in Manhattan; this system was an as-yet undiscovered MG [44].”
BackgroundA review on control of ac microgrid
Rajesh, K. S., Dash, S. S., Rajagopal, R., & Sridhar, R. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.12.106 · Cited by 232 · cited 1×
“However, this network is still widely used nowadays [50].”
BackgroundDistributed Finite-Time Voltage and Frequency Restoration in Islanded AC Microgrids
Zuo, S., Davoudi, A., Song, Y., & Lewis, F. L. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2577542 · Cited by 221 · cited 1×
“regulated based on the conventional distribution system and the operation mode [52].”
BackgroundBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2677943 · Cited by 219 · cited 1×
“in [115].”
Lee, T.-L., Hu, S.-H., & Chan, Y.-H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2166233 · Cited by 216
Classification of power quality events – A review
Saini, M. K., & Kapoor, R. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.04.045 · Cited by 204 · cited 1×
“Furthermore, many studies reviewed the PQ for conventional power systems, such as [37], [38].”
BackgroundStandards and Guidelines for Grid-Connected Photovoltaic Generation Systems: A Review and Comparison
Wu, Y.-K., Lin, J.-H., & Lin, H.-J. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2680409 · Cited by 193
An overview of microgrid protection methods and the factors involved
Hosseini, S. A., Abyaneh, H. A., Sadeghi, S. H. H., Razavi, F., & Nasiri, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.05.089 · Cited by 189 · cited 1×
“Others reviewed various MG applications, including MG stability [39], MG energy management [40], planning and operation of MG [41], MG protection [42], and control strategies of MG systems [43].”
BackgroundDistribution System Harmonic Compensation Methods: An Overview of DG-Interfacing Inverters
Li, Y. W., & He, J. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2295421 · Cited by 184 · cited 1×
“This situation creates voltage problems such as distortion, fluctuation, and voltage sags/swells in a relatively weak system [59].”
BackgroundControl of a Hybrid AC/DC Microgrid Involving Energy Storage and Pulsed Loads
Ma, T., Cintuglu, M. H., & Mohammed, O. A. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2613981 · Cited by 172 · cited 1×
“9 illustrates the single line diagram of a hybrid AC/DC MG [54], [56].”
BackgroundParag, Y., & Ainspan, M. (2019) · Energy Sustainable Development/Energy for sustainable development · doi:10.1016/j.esd.2019.07.003 · Cited by 166 · cited 2×
“minimizing environmental pollution, and reducing electricity bills [4].”
BackgroundHirase, Y., Abe, K., Sugimoto, K., Sakimoto, K., Bevrani, H., & Ise, T. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.06.058 · Cited by 164 · cited 2×
“Typically, the fluctuation of voltage in MG occurs due to changes in solar irradiation, wind speed, battery charge/discharge, and load variations [16].”
BackgroundMethodRay, P. K., Mohanty, S. R., Kishor, N., & Catalão, J. P. S. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2278865 · Cited by 159
Al-Shetwi, A. Q., Hannan, M. A., Ker, P. J., Alkahtani, A. A., & Abas, P. E. (2020) · Electronics · doi:10.3390/electronics9020366 · Cited by 155 · cited 3×
“The SVC is developed to solve various critical PQ problems in MG systems [20], [21], [30].”
BackgroundMethodSelf-citationPower quality issues in the electric power system of the future
Rönnberg, S. K., & Bollen, M. (2016) · The Electricity Journal · doi:10.1016/j.tej.2016.11.006 · Cited by 148 · cited 1×
“15, should be mounted between the switching converter and the grid [109], [110].”
BackgroundMicrogrid and load shedding scheme during islanded mode: A review
Bakar, N. N. A., Hassan, M. Y., Sulaima, M. F., Nasir, M. N. M., & Khamis, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.12.049 · Cited by 138 · cited 1×
“is implemented in MG to store extra power produced from RES and supply stored energy to the grid once the power supply is unable to meet the load demand requirement [49].”
BackgroundPower Quality in DC Power Distribution Systems and Microgrids
Whaite, S. M., Grainger, B. M., & Kwasinski, A. (2015) · Energies · doi:10.3390/en8054378 · Cited by 127 · cited 1×
“Two international standards exist, namely, IEC and IEEE, and different countries with high RES installation, such as Germany and the US, have improved their GCs with new standards [22, 62-67].”
BackgroundMicrogrids in active network management – part II: System operation, power quality and protection
Palizban, O., Kauhaniemi, K., & Guerrero, J. M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.04.048 · Cited by 123 · cited 1×
“The challenges of MG PQ are due to its unique structure, operating mode (connected grid or standalone), type, and configuration of MG distribution resources [58].”
BackgroundKahrobaeian, A., & Mohamed, Y. A. I. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2178045 · Cited by 103 · cited 2×
“High-pass filtration is important to achieve a better dynamic range between the largest and smallest quantities during measurement due to the very small amplitude of the SH components [60], [107], [108].”
BackgroundTechnologies and Applications for Smart Charging of Electric and Plug-in Hybrid Vehicles
Veneri, O. (2016) · Springer eBooks · doi:10.1007/978-3-319-43651-7 · Cited by 95 · cited 1×
“Compared with AC MG, DC MG can offer considerable energy savings by decreasing the number of converters in a single MG system process [53].”
BackgroundHe, J., Liang, B., Li, Y., & Wang, C. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2576684 · Cited by 87 · cited 1×
“Other controllers are also used, such as coordinated control of dual-interfacing converters in [36] to compensate for MG voltage unbalance and current harmonics.”
BackgroundLian, Y., Tai, N., Fan, C., & Meng, Y. (2016) · Renewable Energy · doi:10.1016/j.renene.2016.04.019 · Cited by 76 · cited 1×
“, flywheels, batteries, and energy capacitors) and flexible loads [46].”
BackgroundIEC 61850-7-420 communications standard for distributed energy resources (DER)
Cleveland, F. M. (2008) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2008.4596553 · Cited by 73 · cited 2×
“As imposed by IEC standards, voltage fluctuations can vary by ±10% of its nominal value [80], [93].”
BackgroundLow‐voltage ride‐through of a droop‐based three‐phase four‐wire grid‐connected microgrid
Sadeghkhani, I., Golshan, M. E. H., Mehrizi‐Sani, A., & Guerrero, J. M. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2017.1306 · Cited by 68 · cited 1×
“For instance, a mitigation technique for voltage sag in MG according to IEEE standards is proposed in [14] and according to German GC in [15].”
MethodSupraharmonics from power electronics converters
Rönnberg, S. K., Gil-de-Castro, A., Bollen, M., Moreno‐Muñoz, A., & Romero‐Cadaval, E. (2015) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2015.7231133 · Cited by 64 · cited 1×
“Finally, SH are known to cause instability in weak networks with inverters of MG systems, with the consequent spurious tripping of inverters [100-102].”
BackgroundSummation law for supraharmonic currents (2–150 kHz) in low-voltage installations
Espín-Delgado, Á., Rönnberg, S. K., Busatto, T., Ravindran, V., & Bollen, M. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106325 · Cited by 63 · cited 3×
“The resulting currents are referred to as primary emission and secondary emission [7].”
BackgroundInfluentialSupraharmonic analysis by filter bank and compressive sensing
Mendes, T. M., Duque, C. A., Silva, L. R. M., Ferreira, D. D., & Meyer, J. (2019) · Electric Power Systems Research · doi:10.1016/j.epsr.2018.12.016 · Cited by 58 · cited 1×
“The authors in [111] proposed a method to access the SHwith sampling reduction on the basis of compressive sensing and analog filter bank.”
MethodPower Quality Analysis for PV Grid Connected System Using PSCAD/EMTDC
Kow, K. W., Wong, Y. W., Rajkumar, R. K., & Rajkumar, R. K. (2015) · International Journal of Renewable Energy Research · doi:10.20508/ijrer.v5i1.1847.g6477 · Cited by 54
An Optimal Secondary Voltage Control Strategy for an Islanded Multibus Microgrid
Yang, X., Du, Y., Su, J., Chang, L., Shi, Y. G., & Lai, J. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2602367 · Cited by 52 · cited 1×
“It was used for the same purpose in islanded MG by the authors in [121] and showed good performance.”
MethodComparative analysis of the measurement methods for the supraharmonic range
Mendes, T. M., Duque, C. A., Silva, L. R. M., et al. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105801 · Cited by 50 · cited 2×
“Finally, SH are known to cause instability in weak networks with inverters ofMG systems, with the consequent spurious tripping of inverters [100]–[102].”
BackgroundKim, J. E., & Tang, T. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109738 · Cited by 49 · cited 1×
“These standards cover different issues related to the integration of technical problems and PQ issues, which are investigated and reviewed extensively in ýthe literature [10]–[13].”
BackgroundShabestary, M. M., & Mohamed, Y. A. I. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2948131 · Cited by 33 · cited 1×
“1 s; otherwise, disconnection is compulsory [72], [73].”
Voltage sag/swell waveform analysis method based on multi‐dimension characterisation
Hu, W., Xiao, X., & Zheng, Z. (2019) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2019.1038 · Cited by 27 · cited 1×
“Swell, the behavior of which is opposite that of sag, is another serious PQ issue; however, it rarely occurs [70].”
BackgroundPower quality aspects of solar power – results from CIGRE JWG C4/C6.29
Smith, J., Rönnberg, S. K., Bollen, M., Meyer, J., Blanco, A. M., Koo, K.-L., & Mushamalirwa, D. (2017) · CIRED - Open Access Proceedings Journal · doi:10.1049/oap-cired.2017.0351 · Cited by 25 · cited 1×
“High-frequency emissions in future grids and the impact on connected consumers are expected to increase [98].”
BackgroundSamal, S., & Hota, P. K. (2017) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v8.i3.pp1416-1426 · Cited by 24 · cited 3×
“11%, which meets the IEEE 519-1992 standards of less than 5% [31].”
BackgroundMethodOptimal voltage control strategy for grid-feeding power converters in AC microgrids
Chhor, J., & Sourkounis, C. (2019) · Electric Power Systems Research · doi:10.1016/j.epsr.2019.105945 · Cited by 19
ANN-Based SVC Tuning for Voltage and Harmonics Control in Microgrids
Loureiro, P., Variz, A. M., de Oliveira, L. W., Oliveira, A. R., & Pereira, J. L. R. (2016) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-016-0281-z · Cited by 14 · cited 15×
“Among the devices used to mitigate the PQ issues in MG, UPQC and DVR are the best, followed by STATCOM and SVC.”
BackgroundResultInfluential
Cited by
Al-Shetwi, A. Q. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.153645 · Cited by 703
Self-citationGrid integration impacts and control strategies for renewable based microgrid
Fazal, S., Enamul Haque, M., Taufiqul Arif, M., Gargoom, A., & Oo, A. M. T. (2023) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2023.103069 · Cited by 74
Stochastic Approach for Increasing the PV Hosting Capacity of a Low-Voltage Distribution Network
Bendík, J., Cenký, M., Cintula, B., Beláń, A., Eleschová, Ž., & Janiga, P. (2022) · Processes · doi:10.3390/pr11010009 · Cited by 26
Metadata
- Authors
- Alkahtani, A. A., Alfalahi, S. T. Y., Athamneh, A. A., Al-Shetwi, A. Q., Mansor, M. B., Hannan, M. A., & Agelidis, V. G.
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 127104-127122
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3041059612
- Cited by
- 195
- References
- 52
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.