Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 651

The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.

Reliable Tuberculosis Detection Using Chest X-Ray With Deep Learning, Segmentation and Visualization

Open access
Rahman, Tawsifur, Khandakar, Amith, Kadir, Muhammad Abdul, Islam, Khandaker Rejaul, Islam, Khandakar F., Mazhar, Rashid, Hamid, Tahir, Islam, Mohammad Tariqul, Kashem, Saad, Mahbub, Zaid Bin, Ayari, Mohamed Arselene, Chowdhury, Muhammad E. H.·2020·IEEE Access

Abstract

Tuberculosis (TB) is a chronic lung disease that occurs due to bacterial infection and is one of the top 10 leading causes of death. Accurate and early detection of TB is very important, otherwise, it could be life-threatening. In this work, we have detected TB reliably from the chest X-ray images using image pre-processing, data augmentation, image segmentation, and deep-learning classification techniques. Several public databases were used to create a database of 3500 TB infected and 3500 normal chest X-ray images for this study. Nine different deep CNNs (ResNet18, ResNet50, ResNet101, ChexNet, InceptionV3, Vgg19, DenseNet201, SqueezeNet, and MobileNet) were used for transfer learning from their pre-trained initial weights and were trained, validated and tested for classifying TB and non-TB normal cases. Three different experiments were carried out in this work: segmentation of X-ray images using two different U-net models, classification using X-ray images and that using segmented lung images. The accuracy, precision, sensitivity, F1-score and specificity of best performing model, ChexNet in the detection of tuberculosis using X-ray images were 96.47%, 96.62%, 96.47%, 96.47%, and 96.51% respectively. However, classification using segmented lung images outperformed that with whole X-ray images; the accuracy, precision, sensitivity, F1-score and specificity of DenseNet201 were 98.6%, 98.57%, 98.56%, 98.56%, and 98.54% respectively for the segmented lung images. The paper also used a visualization technique to confirm that CNN learns dominantly from the segmented lung regions that resulted in higher detection accuracy. The proposed method with state-of-the-art performance can be useful in the computer-aided faster diagnosis of tuberculosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2020.3031384

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Cited by

See all 651

Metadata

Authors
Rahman, T., Khandakar, A., Kadir, M. A., Islam, K. R., Islam, K. F., Mazhar, R., Hamid, T., Islam, M. T., Kashem, S., Mahbub, Z. B., Ayari, M. A., & Chowdhury, M. E. H.
Venue
IEEE Access
Published
2020
Volume
8
Pages
191586-191601
ISSN
2169-3536 (ISSN-L)
OpenAlex
W3045801508
Cited by
651
References
64
FWCI
31.15
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliable Tuberculosis Detection Using Chest X-Ray With Deep Learning, Segmentation and Visualization. https://app.cochat.ai/papers/10.1109/access.2020.3031384
The paper
Rahman, T., Khandakar, A., Kadir, M. A., Islam, K. R., Islam, K. F., Mazhar, R., Hamid, T., Islam, M. T., Kashem, S., Mahbub, Z. B., Ayari, M. A., & Chowdhury, M. E. H. (2020). Reliable Tuberculosis Detection Using Chest X-Ray With Deep Learning, Segmentation and Visualization. IEEE Access. https://doi.org/10.1109/access.2020.3031384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.