CoChat

CardioXNet: A Novel Lightweight Deep Learning Framework for Cardiovascular Disease Classification Using Heart Sound Recordings

Open access
Shuvo, Samiul Based, Ali, Shams Nafisa, Swapnil, Soham Irtiza, Al-Rakhami, Mabrook S., Gumaei, Abdu · 2021 · IEEE Access
Cited by 213

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The alarmingly high mortality rate and increasing global prevalence of cardiovascular diseases (CVDs) signify the crucial need for early detection schemes. Phonocardiogram (PCG) signals have been historically applied in this domain owing to its simplicity and cost-effectiveness. In this article, we propose CardioXNet, a novel lightweight end-to-end CRNN architecture for automatic detection of five classes of cardiac auscultation namely normal, aortic stenosis, mitral stenosis, mitral regurgitation and mitral valve prolapse using raw PCG signal. The process has been automated by the involvement of two learning phases namely, representation learning and sequence residual learning. Three parallel CNN pathways have been implemented in the representation learning phase to learn the coarse and fine-grained features from the PCG and to explore the salient features from variable receptive fields involving 2D-CNN based squeeze-expansion. Thus, in the representation learning phase, the network extracts efficient time-invariant features and converges with great rapidity. In the sequential residual learning phase, because of the bidirectional-LSTMs and the skip connection, the network can proficiently extract temporal features without performing any feature extraction on the signal. The obtained results demonstrate that the proposed end-to-end architecture yields outstanding performance in all the evaluation metrics compared to the previous state-of-the-art methods with up to 99.60% accuracy, 99.56% precision, 99.52% recall and 99.68% F1- score on an average while being computationally comparable. This model outperforms any previous works using the same database by a considerable margin. Moreover, the proposed model was tested on PhysioNet/CinC 2016 challenge dataset achieving an accuracy of 86.57%. Finally the model was evaluated on a merged dataset of Github PCG dataset and PhysioNet dataset achieving excellent accuracy of 88.09%. The high accuracy metrics on both primary and secondary dataset combined with a significantly low number of parameters and end-to-end prediction approach makes the proposed network especially suitable for point of care CVD screening in low resource setups using memory constraint mobile devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2021.3063129

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 213

Metadata

Authors
Shuvo, S. B., Ali, S. N., Swapnil, S. I., Al-Rakhami, M. S., & Gumaei, A.
Venue
IEEE Access
Published
2021
Volume
9
Pages
36955-36967
ISSN
2169-3536 (ISSN-L)
OpenAlex
W3135849576
Cited by
213
References
6
FWCI
18.16
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.