The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Adaptive Coordinated Protection for DC Microgrids With Lunar Surface Power Applications
Open accessAbstract
The planned growth of NASA’s Artemis base camp will present new challenges in the operation and control of the expanding EPS. In particular, improved fault detection and isolation methods are needed to protect the microgrid from faults as it undergoes expansion and modifications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Power system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
Power System Analysis and Design
Glover, J. D., & Sarma, M. S. (2007) · Cited by 1,470
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Protection of Low-Voltage DC Microgrids
Salomonsson, D., Soder, L., & Sannino, A. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2016622 · Cited by 712 · cited 1×
“In [17] an overcurrent coordination scheme is proposed but coordinated protection is only designed for a particular architecture and therefore not adaptable to changes in the topology.”
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640 · cited 1×
“Tang develops a method for fault isolation in multi-terminal DC systems (MTDCs) using AC circuit breakers from voltage source inverters (VSIs) to reduce the cost of expensive DC circuit breakers in [11].”
Overcurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems
Baran, M. E., & Mahajan, N. R. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.877086 · Cited by 380 · cited 1×
“In [15] an overcurrent based method is proposed for shipboard microgrids with VSIs but relies on fuses and inverter relays to perform fault coordination.”
Dhar, S., Patnaik, R. K., & Dash, P. K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2654267 · Cited by 380 · cited 1×
“One of the main protection strategies for DC microgrids is the differential current method [7].”
DC Microgrid Protection: A Comprehensive Review
Beheshtaein, S., Cuzner, R. M., Forouzesh, M., Savaghebi, M., & Guerrero, J. M. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2904588 · Cited by 365 · cited 1×
“In this stage, the peak value of the fault current can exceed 100 times the VSC rated current [26].”
Blackburn, J. L., & Domin, T. J. (2006) · CRC Press eBooks · doi:10.1201/9781420017847 · Cited by 217
Novel Fault Detection and Localization Algorithm for Low-Voltage DC Microgrid
Bhargav, R., Bhalja, B. R., & Gupta, C. P. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2942426 · Cited by 156 · cited 1×
“Due to the high rise in fault current in stages I and II, fault protection methods typically aim to isolate the fault before stage III occurs [28] or before the end of the capacitor discharge period, t f , to protect the freewheeling diodes from the large inrush current.”
Research works printed but not linked: 1
- 2022, Moon To Mars Objectives
Cited by
Bo, Y., Liu, K. J. R., Xia, Y., & Wei, W. (2025) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2025.116602 · Cited by 5
Nardone, C. J., Sati, T. E., & Azzouz, M. A. (2026) · IEEE Access · doi:10.1109/access.2026.3654910 · Cited by 2
“In addition, [6], [7], and [8] utilize effective overcurrent-based relaying.”
Intelligent Fault Detection in DC Microgrids Integrating EVs and PVs via HHO-LSTM-GRU
Hooshmand, A., Hooshmand, M., Mohammadi, M., et al. (2026) · International Conference on Protection and Automation of Power Systems (IPAPS) · doi:10.1109/ipaps69408.2026.11499594
“Both current-differential and voltage-differential schemes require communication links, which increase uncertainty and implementation costs in protection systems [15].”
Progress in Lunar DC Microgrid Using Hardware-in-the-Loop Technique
Li, L., Zhang, M., Tang, C., et al. (2026) · IEEE International Conference on DC Microgrids · doi:10.1109/icdcm67837.2026.11594460
“For multi-microgrid scenarios, hierarchical control architectures have been developed, including primary droop control, secondary voltage restoration and current sharing, and tertiary transactive control for power sharing between microgrids [6], [7].”
Lunar surface energy infrastructure: from in-situ resource utilization to deep space exploration
Gao, Y., Shi, Q., Ding, L., Zhou, Y., Zhou, C., & Han, W. (2026) · npj Space Exploration · doi:10.1038/s44453-026-00053-w · Cited by 1
“As the grid expands, multi-path routing and fl exible power-fl ow recon fi guration offer strong protection against faults 120,121 .”
Metadata
- Authors
- Carbone, M. A., Muscatello, M., Collazo Fernandez, X., Gardner, B., & Csank, J.
- Affiliations
- Glenn Research Center (US)
- National Aeronautics and Space Administration, Glenn Research Center, Cleveland, OH, USA
- Venue
- IEEE Access
- Published
- 2025
- Volume
- 13
- Pages
- 134212-134224
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W4412722351
- Semantic Scholar
- 2135fc5770c8fea5fb734fd2914ac576db2dec33
- Cited by
- 5
- References
- 32
- Citations by year
- 2026: 4 · 2025: 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- IEEE Access (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Aeronautics and Space Administration’s (NASA’s) Exploration Systems Development Mission Directorate
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- DC microgrid, fault detection and isolation, single-phase grounding fault, lunar surface power, space power systems, hardware-in-the-loop
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.