Protection of Low-Voltage DC Microgrids

Salomonsson, D., Soder, L., Sannino, A.·2009·IEEE Transactions on Power Delivery

Abstract

In this paper, a low-voltage (LV) DC microgrid protection system design is proposed. The LV DC microgrid is used to interconnect distributed resources and sensitive electronic loads. When designing an LV DC microgrid protection system, knowledge from existing DC power systems can be used. However, in most cases, these systems use grid-connected rectifiers with current-limiting capability during DC faults. In contrast, an LV DC microgrid must be connected to an AC grid through converters with bidirectional power flow and, therefore, a different protection-system design is needed. In this paper, the operating principles and technical data of LV DC protection devices, both available and in the research stage, are presented. Furthermore, different fault-detection and grounding methods are discussed. The influence of the selected protection devices and grounding method on an LV DC microgrid is studied through simulations. The results show that it is possible to use available devices to protect such a system. Problems may arise with high-impedance ground faults which can be difficult to detect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2009.2016622

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 712

Metadata

Authors
Salomonsson, D., Soder, L., & Sannino, A.
Venue
IEEE Transactions on Power Delivery
Published
2009-07
Volume
24
Issue
3
Pages
1045-1053
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W2158017035
Cited by
712
References
0
FWCI
35.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Protection of Low-Voltage DC Microgrids. https://app.cochat.ai/papers/10.1109/tpwrd.2009.2016622
The paper
Salomonsson, D., Soder, L., & Sannino, A. (2009). Protection of Low-Voltage DC Microgrids. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2009.2016622

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.