Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach
The DOI matches its Crossref record.
Abstract
In this work, the effects of motion artifacts on photoplethysmographic signals obtained at fingertip was evaluated. A wavelet-based method was proposed to reduce the influence of motion artifacts on heart rate (HR) and heart rate variability (HRV) estimation. Two kinds of motions were investigated - vertical and circular motions. During the motion, reference signals were acquired at other hand as a standard. Results show that the HR and HRV estimation error can be reduced significantly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“, wavelet transforms [67] and smoothed pseudo Wigner-Ville distributions [68]) may provide better signal enhancement for PPG signals than traditional methods.”
MethodA Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter
Ram, M. R., Madhav, K. V., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2175832 · Cited by 345
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
“Time–frequency methods such as the wavelet transform and the smoothed pseudo Wigner–Ville distribution can be applied to PPG signals showing significant improvement in comparison to traditional approaches [134,137].”
MethodDynamic time warping and machine learning for signal quality assessment of pulsatile signals
Li, Q., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1491 · Cited by 274
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
Reddy, K. A., George, B., & Kumar, V. J. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2009136 · Cited by 165
“Wavelet transform [ 7 ] and third-order independent component analysis (ICA)-based techniques [8] were also proposed for the reduction of motion artifacts.”
MethodA Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151
Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
Zhang, Y., Song, S., Vullings, R., Biswas, D., Simões-Capela, N., van Helleputte, N., van Hoof, C., & Groenendaal, W. (2019) · Sensors · doi:10.3390/s19030673 · Cited by 140
“Besides SSA, empirical mode decomposition (EMD), wavelet decomposition, single measurement vector (SMV) and multiple measurement vector (MMV) methods are used [14].”
MethodSelf-citationHeart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
Naraharisetti, K. V. P., & Bawa, M. (2011) · 2011 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY · doi:10.1109/eit.2011.5978571 · Cited by 35
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33
Motion-Resistant Pulse Oximetry Processing Based on Time-Frequency Analysis
Leeudomwong, T., Deesudchit, T., & Chinrungrueng, C. (2017) · Engineering Journal · doi:10.4186/ej.2017.21.7.181 · Cited by 4
“Most studies focused on the elimination of MA from the corrupted PPG by applying different signal processing techniques; for example, the Fourier series analysis [7], the adaptive filtering [8-12], the independent component analysis [12-15], and the wavelet transform [15, 16].”
Method
Metadata
- Authors
- Lee, C. M., & Zhang, Y. T.
- Venue
- IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, 2003.
- Publisher
- IEEE
- Published
- 2004-07-09
- Pages
- 194-195
- OpenAlex
- W1573847880
- Cited by
- 114
- References
- 0
- FWCI
- 1.19
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.