Direct comparison of silicon and silicon carbide power transistors in high-frequency hard-switched applications
The DOI matches its Crossref record.
Abstract
RECENT progress in wide bandgap power (WBG) switches shows great potential. Silicon carbide (SiC) is a promising material for power devices with breakdown voltages of several hundred volts up to 10 kV. SiC Schottky power diodes have achieved widespread commercial acceptance. Recently, much progress has been made on active SiC switches, including JFETs, thyristors, BJTs, IGBTs, and MOSFETs. Many a great promise has been made, and wondrous claims abound, but the question remains: will they live up to the hype? We explore this question for the class of high-frequency, hard-switched converters with input voltages of up to 600 VDC and power throughputs in the kilowatt range. Experimental evidence shows that both superior efficiency and higher power density may be obtained via the use of SiC MOSFETs. A direct comparison is made using silicon power devices (IGBTs and MOSFETs) and SiC MOSFETs in a 200 kHz, 6 kW, 600 V hard-switched converter. The losses are measured and conduction and switching losses of the active devices are estimated. Total losses can be reduced by a factor of 2-5 by substitution of SiC MOSFETs for Si active power devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oswald, N., Anthony, P., McNeill, N., & Stark, B. H. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2278919 · Cited by 504
Chen, Z., Yao, Y., Boroyevich, D., Ngo, K. D. T., Mattavelli, P., & Rajashekara, K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2283245 · Cited by 277
Investigations of 600-V GaN HEMT and GaN Diode for Power Converter Applications
Mitova, R., Ghosh, R., Mhaskar, U., Klikic, D., Wang, M.-X., & Dentella, A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2286639 · Cited by 221
“Compared to GaN, the SiC device technology is in an advanced stage, where particularly, SiC-based diodes have proven their maturity and robustness in industry applications [14]–[17].”
BackgroundA Short-Circuit Safe Operation Area Identification Criterion for SiC MOSFET Power Modules
Reigosa, P. D., Iannuzzo, F., Luo, H., & Blaabjerg, F. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2628895 · Cited by 97
Sfakianakis, G. E., Everts, J., & Lomonova, E. A. (2015) · 2015 Tenth International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2015.7112939 · Cited by 47
“Moreover, switching frequencies of a few hundred kilohertz in hardswitching operation are feasible [28], [29], while for Si devices this is only possible by employing soft-switching strategies.”
Background
Metadata
- Authors
- Glaser, J. S., Nasadoski, J. J., Losee, P. A., Kashyap, A. S., Matocha, K. S., Garrett, J. L., & Stevanovic, L. D.
- Venue
- 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)
- Publisher
- IEEE
- Published
- 2011-03
- Pages
- 1049-1056
- ISSN
- 1048-2334 (ISSN-L)
- OpenAlex
- W2145654324
- Cited by
- 95
- References
- 0
- FWCI
- 11.31
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.