CoChat

7.2 kV Three-Port Single-Phase Single-Stage Modular Soft-Switching Solid-State Transformer with Active Power Decoupling and Reduced DC-Link

Zheng, Liran, Han, Xiangyu, Kandula, Rajendra Prasad, Kandasamy, Karthik, Saeedifard, Maryam, Divan, Deepak · 2020 · 2020 IEEE Applied Power Electronics Conference and Exposition (APEC)
Cited by 33

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This paper proposes a single-stage modular medium-voltage soft-switching solid-state transformer (M-S4T). The 7.2 kV 50 kVA M-S4T consists of five stacked 1.44 kV 10 kVA single-phase converter modules using 3.3 kV SiC MOSFETs and diodes in reverse blocking mode. The proposed converter has some unique features. First, the M-S4T is a medium-voltage stacked converter with reduced dc-link. Second, the M-S4T has a three-port structure (MVAC, LVAC, LVDC) for renewable, storage integration, or EV fast charging. Third, the M-S4T is a single-phase medium-voltage converter with active power decoupling, i.e. using a buffer port for 120 Hz power absorption to avoid large dc-link passives. According to the literature, though already applied to low-voltage converters for improved power density, the reduced dc-link and active power decoupling strategies have not been used in medium-voltage converters before. With high-frequency isolation, reduced dc-link, and a 120 Hz active power decoupling port, passive components in the MS4T can be minimized - which often dominate the size of medium-voltage converters. Also, the M-S4T is electrolytic capacitor less and high reliability is achieved - critical for utility applications like SST. Moreover, the 7.2 kV M-S4T has low EMI through low dv/dt, and high efficiency (~97% expected at full power) over the full load range with ZVS technique. Finally, the transformer of the M-S4T is designed to pass 55 kV basic-insulation level (BIL) and 60 kV high potential (Hipot) dielectrics withstand test - major challenges for SST. The topology, design, operating principle, controls, and simulation results are presented. These concepts are finally verified with experimental results at 2 kV peak of a single converter module and 1.6 kV peak of two stacked modules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/apec39645.2020.9124244

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 33

Metadata

Authors
Zheng, L., Han, X., Kandula, R. P., Kandasamy, K., Saeedifard, M., & Divan, D.
Venue
2020 IEEE Applied Power Electronics Conference and Exposition (APEC)
Publisher
IEEE
Published
2020-03
Pages
1575-1581
OpenAlex
W3037905309
Cited by
33
References
2
FWCI
9.44
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.