The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index; 2 of the 7 sources its claims cite were checked for support.
7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection
Open accessAbstract
This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blockingmosfet-plus-diode modules. The proposed SST has some unique features. First, compared with the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated ac/dc or ac/ac conversion with an inductive dc link, but no medium-voltage (MV) ac experiments have been reported. This article for the first time demonstrates MV ac current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase ac grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced dc link and the electrolytic capacitor-less SST with high reliability. Third, for a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlleddv/dtfor low electromagnetic interference. These concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.
Overview
CoChat Summary
TL;DR
This paper proposes and demonstrates a 7.2 kV 50 kVA three-port modular single-stage current-source SiC solid-state transformer with a 120 Hz active-power-decoupling buffer port and a lightning protection scheme. The prototype uses five input-series output-parallel modules and is tested up to 7.5 kV peak, with an MFT passing 55 kV BIL/60 kV Hipot at 0.09% leakage inductance and protection verified against 90 kV BIL impulse.
Key findings
- First MV AC current-source SST experimental demonstration: a 7.2 kV oil-cooled prototype with five ISOP modules based on 3.3 kV SiC reverse-blocking modules, tested up to 7.5 kV peak under steady-state and dynamic conditions; reported tests include single-module 2 kV peak 6 kW, five-module 5 kV peak 3.5 kVA, 7.5 kV peak 8 kW, and 7.5 kV peak 20 kVA.
- The active-power-decoupling buffer port absorbs the 120 Hz ripple, enabling a reduced DC link and electrolytic capacitor-less SST; the buffer capacitor is 5.3 mF tolerating 30% peak-to-peak ripple versus 79.5 mF for 2% ripple without APD, giving a 53.8% total SST prototype volume saving (319.4 L vs 692.0 L).
- The MFT passes 60 kV Hipot and 55 kV BIL, with measured leakage inductance of 181.5 nH (0.09% of magnetizing inductance) and Lm of 192 µH at 150 A and 159 µH at 180 A; the lightning protection scheme limits v_Mf to 13.1 kV under a 90 kV 1.2/50 µs impulse, within the stated 15 kV safe range.
- ZVS and controlled dv/dt are verified: over 90% switching loss reduction under ZVS versus hard switching from 400 V 5 A to 2 kV 25 A; MV dv/dt is less than 800 V/µs and LV dv/dt less than 200 V/µs; estimated peak efficiency is close to 96% for one 10 kVA module, limited by 650 V discrete device conduction loss at about 65% of total loss.
Methods
- Design and hardware: a 7.2 kV 50 kVA SST with five ISOP 1.44 kV to 350 V, 10 kVA modules; MV side uses 3.3 kV 45 A SiC reverse-blocking modules, LV side uses 650 V Si IGBTs plus SiC diodes; the prototype includes an MFT, resonant circuits, filters, and forced oil cooling.
- Control and analysis: predictive control extended from model predictive priority-shifting control with active power decoupling and reduced DC link; distributed DSP/FPGA controllers compute current references and vector timings; equations cover resonant/ZVS durations, filter sizing, and loss estimation, supported by double-pulse characterization and simulations.
- Experiments: single-module and five-module steady-state and dynamic tests up to 7.5 kV peak; MFT Hipot/BIL tests; lightning impulse tests using a 90 kV 1.2/50 µs generator; efficiency measurement and estimation for a 10 kVA module.
Limitations
- Stated in the paper: MFT insulation degradation and lifetime, partial discharge, and the impact of high-frequency switching are identified as needing further exploration; efficiency is mainly limited by 650 V discrete device conduction loss, with future SiC MOSFETs or more paralleled devices projected to improve peak efficiency to about 97%.
- Evident from the text: experimental validation reaches 7.5 kV peak and 20 kVA, below the 50 kVA prototype rating; the 250/2500 µs switching impulse verification is simulation-based, while the 90 kV 1.2/50 µs lightning impulse test is experimental.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
2 Valid · 2 Not valid · 5 Not checked · 66 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“only one MV current-source SST prototype has been reported, i.e., a 5 kV DC-DC M-S4T prototype in [27].”
What the sources say
- Partly supportedcites [27] [27] L. Zheng, X. Han, Z. An, R. P. Kandula, K. Kandasamy, M. Saeedifard, and D. Divan, 'SiC-Based 5 kV Universal Modular Soft-Switching SolidState Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids,' IEEE Trans. Power Electron. , vol. 36, no. 10, pp. 11326-11343, Oct. 2021. - sourceExperimental — accuracy not yet measured
The available paper description (section and page unavailable) identifies the M-S4T as a 5 kV current-source SST designed for DC-to-DC or DC-to-AC conversion. It reports 4 kV experimental results and an MV transformer prototype, but does not establish a 5 kV DC-to-DC SST prototype or the claim that it is the only reported MV current-source SST prototype. (LLM, conf=0.86)
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The components in the proposed lightning protection scheme have been modeled to simulate the proposed scheme, where the simulation results match experimental measurements [43].”
What the sources say
- Supportedcites [43] source
In Section IV.D (Discussions), the paper compares simulated waveforms with lightning impulse test results and says they match closely. It reports a simulated peak voltage of 13.2 kV versus a measured 13.0 kV, within 2% error. (LLM, conf=0.94)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Then, the total ZVS transition state duration in Fig. 3 can be calculated using (20) to be 5 µs.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“L m is measured to be 192 µH at 150 A and 159 µH at 180 A due to soft saturation,”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The current required is the sum of the buffer current peak, the MV current peak, and the LV port's current over the effective duty cycle as computed by (15) to be 140 A.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
40 more claims
Create a free account to see all 75 claims and every source verdict.
- It may state two separate claims as one. 23
- The quote only partly states this claim. 3
- Probably not a substantial claim. 6
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ B. Control of the Proposed SST · p. 4
“where the resonant state duration ( 𝑇𝑇 Res ) and the ZVS transition state duration ( 𝑇𝑇ZVS ) correspond to states 0 and 5 in Fig. 2 (a), respectively.”
§ A. Topology and Operation Principle of the Proposed SST · p. 3
“a ZVS transition state (state 0) and/or a resonant state (state 5).”
Citations
Cites
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Self-citationPerformance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Self-citationSteinmetz, C. P. (1984) · Proceedings of the IEEE · doi:10.1109/proc.1984.12842 · Cited by 656
A High Power Density Single-Phase PWM Rectifier With Active Ripple Energy Storage
Wang, R., Wang, F., Boroyevich, D., Burgos, R., Lai, R., Ning, P., & Rajashekara, K. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090670 · Cited by 581
Krein, P. T., Balog, R. S., & Mirjafari, M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2186640 · Cited by 520
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371
Ferreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M. (2017) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2017.2692381 · Cited by 303 · cited 1×
“In traction locomotive [4], renewable energy integration [5]–[7], and data”
BackgroundPower Electronic Traction Transformer-Low Voltage Prototype
Dujic, D., Zhao, C., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2248756 · Cited by 293
Cited by
Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279030 · Cited by 111
“The series-input connection provides the opportunity to utilize LV devices to handle MV input, as reported in [16] and [17].”
MethodHigh-Power Electronic Applications Enabled by Medium Voltage Silicon-Carbide Technology: An Overview
Nielsen, M. R., Deng, S., Mirza, A. B., Kjærsgaard, B. F., Jørgensen, A. B., Zhao, H., Li, Y., Munk‐Nielsen, S., & Luo, F. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3442483 · Cited by 92
“3–15kVSiC MOSFET s targeted at grid applications are given in [251], [252], [253], [254], [255], [256], [257], [258], and [259].”
Zheng, L., Kandula, R. P., & Divan, D. M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3211000 · Cited by 54
“2 kV multiport CS SST [29] is under test.”
BackgroundMethodSelf-citationWald, F., Hrishikesan, V. M., Gomis‐Bellmunt, O., Ji, H., Davoudi, M., Bidram, A., Syed, M. H., Joševski, M., Brüske, S., Kumar, C., et al. (2025) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2025.3574007 · Cited by 43
“It is a first demonstration of the concept and requires further investigation to prove its feasibility [148].”
Power Loss Minimization in Smart Transformer Enabled Low Voltage Islanded Meshed Hybrid Microgrid
Das, D., Manojkumar, R., Kumar, C., & Ganguly, S. (2022) · IEEE Access · doi:10.1109/access.2022.3224001 · Cited by 24
“In [12], a SiC based single stage ST is proposed with superior features like single stage operation, buffer port for active power decoupling, lightning protection, modular structure and soft switching capabilities.”
Method
Metadata
- Authors
- Zheng, L., Han, X., Xu, C., Kandula, R. P., Graber, L., Saeedifard, M., & Divan, D.
- Affiliations
- Georgia Institute of Technology (US)
- Tesla (United States) (US)
- Oak Ridge National Laboratory (US)
- ORCID
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2022-10
- Volume
- 37
- Issue
- 10
- Pages
- 12080-12094
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W4285116844
- Cited by
- 42
- References
- 43
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 7 · 2023: 13 · 2022: 4
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Advanced Research Projects Agency - Energy
- U.S. Department of Energy (DE-AR0000899)
- CIRCUITS
- Center for Distributed Energy, Georgia Institute of Technology
- Georgia Institute of Technology
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, current source converter, multiport converter, SiC MOSFET, lightning protection, active power decoupling, energy storage integration, medium frequency transformer, zero-voltage switching, electromagnetic interference, photovoltaic grid connection, electric vehicle fast charging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection. https://app.cochat.ai/papers/10.1109/tpel.2022.3172946
- The paper
- Zheng, L., Han, X., Xu, C., Kandula, R. P., Graber, L., Saeedifard, M., & Divan, D. (2022). 7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2022.3172946
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.