The DOI matches its Crossref record.
A Floor Sensor System for Gait Recognition
Abstract
This paper describes the development of a prototype floor sensor as a gait recognition system. This could eventually find deployment as a standalone system (e.g. a burglar alarm system) or as part of a multimodal biometric system. The new sensor consists of 1536 individual sensors arranged in a 3 m by 0.5 m rectangular strip with an individual sensor area of 3 cm/sup 2/. The sensor floor operates at a sample rate of 22 Hz. The sensor itself uses a simple design inspired by computer keyboards and is made from low cost, off the shelf materials. Application of the sensor floor to a small database of 15 individuals was performed. Three features were extracted : stride length, stride cadence, and time on toe to time on heel ratio. Two of these measures have been used in video based gait recognition while the third is new to this analysis. These features proved sufficient to achieve an 80% recognition rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
Deep learning enabled smart mats as a scalable floor monitoring system
Shi, Q., Zhang, Z., He, T., Sun, Z., Wang, B., Feng, Y., Shan, X., Salam, B., & Lee, C. (2020) · Nature Communications · doi:10.1038/s41467-020-18471-z · Cited by 315
(2019) · ACM Computing Surveys · doi:10.1145/3230633 · Cited by 303
Biometric recognition by gait: A survey of modalities and features
Connor, P., & Ross, A. (2018) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2018.01.007 · Cited by 272
Indoor location based services challenges, requirements and usability of current solutions
Basiri, A., Lohan, E. S., Moore, T., Winstanley, A., Peltola, P., Hill, C., Amirian, P., & Figueiredo e Silva, P. (2017) · Computer Science Review · doi:10.1016/j.cosrev.2017.03.002 · Cited by 268
mID: Tracking and Identifying People with Millimeter Wave Radar
Zhao, P., Lu, C. X., Wang, J., Chen, C., Wang, W., Trigoni, N., & Markham, A. (2019) · 2019 15th International Conference on Distributed Computing in Sensor Systems (DCOSS) · doi:10.1109/dcoss.2019.00028 · Cited by 266
Deep Learning for Monitoring of Human Gait: A Review
Alharthi, A. S., Yunas, S. U., & Ozanyan, K. B. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2928777 · Cited by 175
Gait-based Person Re-identification: A Survey
Nambiar, A., Bernardino, A., & Nascimento, J. C. (2020) · ACM Computing Surveys · doi:10.1145/3243043 · Cited by 96
Costilla-Reyes, O., Vera-Rodriguez, R., Scully, P., & Ozanyan, K. B. (2019) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2018.2799847 · Cited by 78
IoT-based Technologies for Addressing the Unique Healthcare Needs of the Elderly Population
Ali, S. A., & Khan, R. (2023) · doi:10.20944/preprints202303.0088.v1 · Cited by 7
Classification of User Movement Data
Arias, P., Kelley, C., Mason, J., Bryant, K., & Roy, K. (2018) · Proceedings of the 2nd International Conference on Digital Signal Processing · doi:10.1145/3193025.3193036 · Cited by 6
Metadata
- Authors
- Middleton, L., Buss, A. A., Bazin, A., & Nixon, M. S.
- Venue
- Fourth IEEE Workshop on Automatic Identification Advanced Technologies (AutoID'05)
- Publisher
- IEEE
- Published
- 2006-10-11
- Pages
- 171-176
- OpenAlex
- W1516653016
- Cited by
- 227
- References
- 0
- FWCI
- 17.54
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.