The experiment study on infrared radiation spectrum of human body
Abstract
Infrared thermography is a non-contact measurement method which is widely used in human body temperature monitoring. But there are still some limitations when infrared thermography is used in medical diagnosis, so the accuracy of infrared thermal imaging is still being debated. Spectroscopic analysis is a powerful technology. It not only can reflect the relative temperature difference accurately, but also can get the energy information of human body at different spectral coverages. We measured the infrared radiation spectrum (Spectral Range: 1.33μm~16.67μm) of human body by using high precision spectrometer, and found some interesting results. The regular changes of the infrared radiation spectrums which are measured at different time have been discussed in this paper. More information about the human body condition can be gotten from these regular changes. Our Future work will focus on the correlation between the radiation energy distribution changes of spectrum and the physiological changes of human body.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm.
“Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm, thus the sensor must be adapted to the radiation wavelength of human body temperature [130,157].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [130]
Cites
Nanoshell-Enabled Photonics-Based Imaging and Therapy of Cancer
Loo, C. H., Lin, A. W. H., Hirsch, L. R., et al. (2004) · Technology in Cancer Research & Treatment · doi:10.1177/153303460400300104 · Cited by 1,163 · see citing works
A reappraisal of the use of infrared thermal image analysis in medicine
Jones, B. F. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746635 · Cited by 573 · see citing works
Arora, N., Martins, D. F., Ruggerio, D., Tousimis, E. A., Swistel, A. J., Osborne, M. P., & Simmons, R. M. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2008.06.015 · Cited by 322 · see citing works
Infrared imaging technology and biological applications
Kastberger, G., & Stachl, R. (2003) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03195520 · Cited by 197 · see citing works
Infrared thermography: Experience from a decade of pediatric imaging
Saxena, A. K., & Willital, G. H. (2007) · European Journal of Pediatrics · doi:10.1007/s00431-007-0583-z · Cited by 111 · see citing works
The Technique of Infrared Imaging in Medicine
Boonsuk, W., & Hongma, P. (2022) · Journal of Applied Science · doi:10.14416/j.appsci.2022.02.004 · Cited by 102 · see citing works
Effect of Forced Convection on the Skin Thermal Expression of Breast Cancer
Hu, L., Gupta, A., Gore, J. P., et al. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1688779 · Cited by 59 · see citing works
Arora, I. (2008) · Cited by 58 · see citing works
Skin Temperature Measurement Method
Peng, Y.-H., Lian, Z., & Li, P. (2010) · Journal of Southeast University · Cited by 7 · see citing works
Hu, X. (2003) · JOURNAL OF INFRARED AND MILLIMETER WAVES · Cited by 6 · see citing works
Review of Progress in Surface Temperature of Acupoint
Zhu, J. (2010) · Journal of Clinical Acupuncture and Moxibustion · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103 · see citing works
- Authors
- Yu, W. L., Wang, Z., & Jin, L.
- Affiliations
- Chinese Academy of Sciences (CN)
- ORCID
- Zhen Wang
- Venue
- Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics
- Publisher
- IEEE
- Published
- 2012-01
- Volume
- 26
- Pages
- 752-754
- ISSN
- 2641-3590 (ISSN-L)
- OpenAlex
- W1964096786
- Cited by
- 9
- References
- 11
- Citations by year
- 2023: 1 · 2022: 4 · 2021: 1 · 2017: 1 · 2015: 2
- FWCI
- 1.88
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- infrared thermography, spectral energy distribution, body temperature monitoring, diagnosis, physiological changes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review