Cited by 9Infrared Thermography in MedicineThermography and Photoacoustic TechniquesSpectroscopy Techniques in Biomedical and Chemical Research

The experiment study on infrared radiation spectrum of human body

Yu, W. L., Zhen Wang, Lei Jin·2012·Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics

Abstract

Infrared thermography is a non-contact measurement method which is widely used in human body temperature monitoring. But there are still some limitations when infrared thermography is used in medical diagnosis, so the accuracy of infrared thermal imaging is still being debated. Spectroscopic analysis is a powerful technology. It not only can reflect the relative temperature difference accurately, but also can get the energy information of human body at different spectral coverages. We measured the infrared radiation spectrum (Spectral Range: 1.33μm~16.67μm) of human body by using high precision spectrometer, and found some interesting results. The regular changes of the infrared radiation spectrums which are measured at different time have been discussed in this paper. More information about the human body condition can be gotten from these regular changes. Our Future work will focus on the correlation between the radiation energy distribution changes of spectrum and the physiological changes of human body.

Integrity signals

Registry

Crossref · 10.1109/bhi.2012.6211692

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm.

    “Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm, thus the sensor must be adapted to the radiation wavelength of human body temperature [130,157].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [130]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yu, W. L., Wang, Z., & Jin, L.
Affiliations
Chinese Academy of Sciences (CN)
Venue
Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics
Publisher
IEEE
Published
2012-01
Volume
26
Pages
752-754
ISSN
2641-3590 (ISSN-L)
OpenAlex
W1964096786
Cited by
9
References
11
Citations by year
2023: 1 · 2022: 4 · 2021: 1 · 2017: 1 · 2015: 2
FWCI
1.88
Type
conference paper
Language
en
Open access
closed
Locations
IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
infrared thermography, spectral energy distribution, body temperature monitoring, diagnosis, physiological changes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review