Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

A deep learning approach to monitoring and detecting atrial fibrillation using wearable technology

Shashikumar, Supreeth Prajwal, Shah, Amit J., Li, Qiao, Clifford, Gari D., Nemati, Shamim·2017·2017 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI)

Abstract

Atrial Fibrillation (AF) is the most common cardiac arrhythmia in clinical practice, with a prevalence of 2% in the community. Not only it is associated with reduced quality of life, but also increased risk of stroke and myocardial infarction. Unfortunately, many cases of AF are clinically silent and undiagnosed, but long-term monitoring is difficult. Nonetheless, efforts at monitoring at-risk individuals and detecting clinically silent AF may yield significant public health benefit, as individuals with new-onset, asymptomatic AF would receive preventive therapies with anticoagulants and beta-blockers, for example. Wearables have enormous potential to provide low-risk and low-cost long-term monitoring of AF, but signals from such devices suffer from significant movement related noise that resembles AF. This work presents a robust approach to AF detection in a sequence of short windows with significant movement artifact. Pulsatile photoplethysmographic (PPG) data and triaxial accelerometry from 98 subjects (45 with AF and 53 with other rhythms) were captured using a multichannel wrist-worn device. A single channel electrocardiogram (ECG) was recorded (for rhythm verification only) simultaneously. A novel deep neural network approach to classify AF from wrist-worn PPG signals was developed on this data. A continuous wavelet transform was applied to the PPG data and a convolutional neural network (CNN) was trained on the derived spectrograms to detect AF. Combining the output of the CNN with features calculated based on beat-to-beat variability and signal quality provided a significant accuracy boost. Leave-one-out cross validation resulted in a pooled AUC of 0.95 (Accuracy=91.8%). The proposed approach resulted in a novel robust and accurate algorithm for detection of AF from PPG data, which is scalable and likely to improve in accuracy as the dataset size continues to expand.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/bhi.2017.7897225

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 164

Metadata

Authors
Shashikumar, S. P., Shah, A. J., Li, Q., Clifford, G. D., & Nemati, S.
Venue
2017 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI)
Publisher
IEEE
Published
2017
Pages
141-144
OpenAlex
W2606856422
Cited by
164
References
9
FWCI
42.99
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A deep learning approach to monitoring and detecting atrial fibrillation using wearable technology. https://app.cochat.ai/papers/10.1109/bhi.2017.7897225
The paper
Shashikumar, S. P., Shah, A. J., Li, Q., Clifford, G. D., & Nemati, S. (2017). A deep learning approach to monitoring and detecting atrial fibrillation using wearable technology. 2017 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI). https://doi.org/10.1109/bhi.2017.7897225

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.