The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
An ultra-wearable, wireless, low power ECG monitoring system
Abstract
Wearable electrocardiograph (ECG) monitoring systems today use electrodes that require skin preparation in advance, and require pastes or gels to make electrical contact to the skin. Moreover, they are not suitable for subjects at high levels of activity due to high noise spikes that can appear in the data. To address these problems, a new class of miniature, ultra low noise, capacitive sensor that does not require direct contact to the skin, and has comparable performance to gold standard ECG electrodes, has been developed. This paper presents a description and evaluation of a wireless version of a system based on these innovative ECG sensors. We use a wearable and ultra low power wireless sensor node called Eco. Experimental results show that the wireless interface will add minimal size and weight to the system while providing reliable, untethered operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Telos: enabling ultra-low power wireless research
Polastre, J., Szewczyk, R., & Culler, D. (2005) · Cited by 1,735
Telos: enabling ultra-low power wireless research
Polastre, J., Szewczyk, R., & Culler, D. (2005) · IPSN 2005. Fourth International Symposium on Information Processing in Sensor Networks, 2005. · doi:10.1109/ipsn.2005.1440950 · Cited by 928
Sensor networks for medical care
Shnayder, V., Chen, B.-R., Lorincz, K., Jones, T. R. F. F., & Welsh, M. (2005) · Proceedings of the 3rd international conference on Embedded networked sensor systems · doi:10.1145/1098918.1098979 · Cited by 720
Fensli, R., Gunnarson, E., & Gundersen, T. (2005) · 18th IEEE Symposium on Computer-Based Medical Systems (CBMS'05) · doi:10.1109/cbms.2005.22 · Cited by 192
Krahn, A. D., Klein, G. J., Yee, R., & Norris, C. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00237-9 · Cited by 151
Eco: Ultra-Wearable and Expandable Wireless Sensor Platform
Park, C., & Chou, P. H. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN) · doi:10.1109/bsn.2006.21 · Cited by 84
Self-citationDevelopment and Evaluation of a Bluetooth EKG Monitoring Sensor
Proulx, J., Clifford, R., Sorensen, S. D., Lee, D.-J., & Archibald, J. K. (2006) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2006.74 · Cited by 48
Cited by
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Hassanalieragh, M., Page, A., Soyata, T., Sharma, G., Aktas, M., Mateos, G., Kantarci, B., & Andreescu, S. (2015) · 2015 IEEE International Conference on Services Computing · doi:10.1109/scc.2015.47 · Cited by 787
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Metadata
- Authors
- Park, C., Chou, P. H., Bai, Y., Matthews, R., & Hibbs, A.
- Venue
- 2006 IEEE Biomedical Circuits and Systems Conference
- Publisher
- IEEE
- Published
- 2006-11
- Pages
- 241-244
- OpenAlex
- W2134411939
- Cited by
- 262
- References
- 7
- FWCI
- 18.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.