Flexible bioimpedance spectroscopy system for wound care monitoring
Abstract
This paper presents a system for measuring the bioimpedance of a wound, to give an indication of its healing progress without the need to remove the wound dressing. A 16-channel electrode array is printed on a composite nanocellulose-polyurethane substrate that is stretchable, breathable and biocompatible. An electronic readout system consists of an analogue multiplexor, analogue front end interrogated with an integrated impedance measurement device, and an on-board calibration circuit. The readout electronics is implemented on a polyimide flexible substrate, including additional sensing functions, wireless powering and radio communications easily integrated in various wound dressing scenarios. The electrode array is detachable from the readout allowing numerous application specific electrode patch configurations, and reuse of electronics with disposable, single-use electrode patches. The system is characterized measuring a range of known impedances, for measurements on a gelatine phantom and on a healthy human arm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
Research works printed but not linked: 12
- 10.1088/1361-6579/aa63d6 · DOI
- 10.3390/s19112505 · DOI
- 10.1088/0967-3334/29/6/S23 · DOI
- 10.1088/2058-8585/aae5d9 · DOI
- 10.1002/jps.21210 · DOI
- 10.1016/j.msec.2014.12.068 · DOI
- 10.3389/fbioe.2018.00047 · DOI
- 10.1109/TTHZ.2011.2159551 · DOI
- 10.1155/2014/381251 · DOI
- 10.2741/1184 · DOI · Paper page
- 10.1111/j.1524-475X.2009.00543.x · DOI · Paper page
- 10.1177/193229681200600126 · DOI
Metadata
- Authors
- Mc Caffrey, C., Flak, J., Kiri, K., & Pursula, P.
- Affiliations
- VTT Technical Research Centre of Finland (FI)
- Venue
- 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)
- Publisher
- IEEE
- Published
- 2019-10
- Pages
- 1-4
- OpenAlex
- W2991827812
- Cited by
- 14
- References
- 1
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 1
- FWCI
- 2.78
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Biomedical Circuits and Systems Conference (BioCAS) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Health Sciences › Medicine › Surgery › Wound Healing and Treatments
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- bioimpedance spectroscopy, wound healing monitoring, flexible electronics, stretchable sensors, on-chip calibration, wireless power transfer, radio communication, gelatine phantom
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible bioimpedance spectroscopy system for wound care monitoring. https://app.cochat.ai/papers/10.1109/biocas.2019.8919095
- The paper
- Mc Caffrey, C., Flak, J., Kiri, K., & Pursula, P. (2019). Flexible bioimpedance spectroscopy system for wound care monitoring. 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS). https://doi.org/10.1109/biocas.2019.8919095