The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Sensing tactile microvibrations with the BioTac — Comparison with human sensitivity
Abstract
The human fingertip is exquisitely sensitive to vibrations that are essential to detect slip and discriminate textures. Achieving similar functions with prosthetic and robotic hands will require tactile sensors with similar sensitivity. Many technologies have been developed to sense such vibrations, yet none have achieved the requisite sensitivity in a package that is robust enough to meet practical applications. The BioTac®, developed by the authors, uses an incompressible liquid as an acoustic conductor to convey vibrations from the skin to a wide bandwidth pressure transducer located deep in the rigid core of the mechatronic finger, where it is protected from damage. Signal conditioning electronics were designed to achieve sensitivity down to the theoretical noise floor of the transducer, making the device very sensitive to the smallest of vibrations, even sound. We demonstrate here that this device exceeds human performance in detecting sustained vibrations (capable of sensing vibrations as small as a few nanometers at ~330Hz) as well as very small transient events that arise when small particles are dropped on the finger. This overcomes the supposition that such sensitivity requires fragile sensory elements to reside near the vulnerable contact surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
Jones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Biomimetic tactile sensor array
Wettels, N., Santos, V. J., Johansson, R. S., & Loeb, G. E. (2008) · Advanced Robotics · doi:10.1163/156855308x314533 · Cited by 348
Self-citationTactile detection of slip: surface microgeometry and peripheral neural codes
Srinivasan, M. A., Whitehouse, J. M., & LaMotte, R. H. (1990) · Journal of Neurophysiology · doi:10.1152/jn.1990.63.6.1323 · Cited by 290
Detection of Vibration Transmitted Through an Object Grasped in the Hand
Brisben, A. J., Hsiao, S. S., & Johnson, K. O. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1548 · Cited by 259
Research works printed but not linked: 25
- 10.1109/ROBOT.1994.351572 · doi:10.1109/robot.1994.351572
- 10.1109/ROBOT.1984.1087209 · doi:10.1109/robot.1984.1087209
- 10.1109/ROBOT.1994.351253 · DOI
- 10.1109/ROBOT.1989.99981 · DOI · Paper page
- 10.1016/S0957-4158(98)00045-2 · DOI · Paper page
- 10.1109/TRO.2009.2033627 · DOI · Paper page
- 10.1177/027836498900800301 · DOI · Paper page
- 10.1163/156855394X00356 · DOI · Paper page
- 10.1109/ROBOT.1986.1087535 · doi:10.1109/robot.1986.1087535
- dario, 1994, An investigation on a robot system for disassembly automation, Proceedings of IEEE International Conference on Robotics and Automation, 4, 3515
- 10.1109/ROBOT.1994.351132 · doi:10.1109/robot.1994.351132
- 10.1109/37.341866 · DOI
- 10.1109/ROBIO.2011.6181676 · DOI
- 10.1109/BIOROB.2008.4762914 · DOI
- 10.1109/BIOROB.2008.4762917 · DOI
- 10.1109/ROBIO.2009.5420611 · DOI
- 10.1016/0006-8993(82)90899-X · DOI · Paper page
- 10.1007/BF00236209 · DOI · Paper page
- 10.1007/BF00237997 · DOI · Paper page
- mountcastle, 1972, Detection thresholds for stimuli in humans and monkeys: Comparison with threshold events in mechanoreceptive afferent nerve fibers innervating the monkey hand, Journal of Neurophysiology, 35, 122, 10.1152/jn.1972.35.1.122 · DOI · Paper page
- 10.1121/1.3458852 · DOI
- 10.1113/jphysiol.1983.sp014689 · DOI · Paper page
- 10.1007/BF00242914 · DOI
- 10.3758/BF03193537 · DOI · Paper page
- 10.1080/01421590120089640 · DOI · Paper page
Cited by
Lambeta, M., Chou, P.-W., Tian, S., Yang, B., Maloon, B., Most, V. R., Stroud, D., Santos, R., Byagowi, A., Kammerer, G., et al. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2977257 · Cited by 553
Bayesian Exploration for Intelligent Identification of Textures
Fishel, J. A., & Loeb, G. E. (2012) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2012.00004 · Cited by 358
Self-citationA neuro-inspired artificial peripheral nervous system for scalable electronic skins
Lee, W. W., Tan, Y. J., Yao, H., Li, S., See, H. H., Hon, M., Ng, K. A., Xiong, B., Ho, J. S., & Tee, B. C. K. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2198 · Cited by 318
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
A soft thumb-sized vision-based sensor with accurate all-round force perception
Sun, H., Kuchenbecker, K. J., & Martius, G. (2022) · Nature Machine Intelligence · doi:10.1038/s42256-021-00439-3 · Cited by 260
Metadata
- Authors
- Fishel, J. A., & Loeb, G. E.
- Venue
- 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob)
- Publisher
- IEEE
- Published
- 2012-06
- Pages
- 1122-1127
- ISSN
- 2155-1774 (ISSN-L)
- OpenAlex
- W2128681845
- Cited by
- 170
- References
- 5
- FWCI
- 13.65
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensing tactile microvibrations with the BioTac — Comparison with human sensitivity. https://app.cochat.ai/papers/10.1109/biorob.2012.6290741
- The paper
- Fishel, J. A., & Loeb, G. E. (2012). Sensing tactile microvibrations with the BioTac — Comparison with human sensitivity. 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob). https://doi.org/10.1109/biorob.2012.6290741
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.