Development of a wearable ZigBee sensor system for upper limb rehabilitation robotics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a new tool for assessment and therapy in post-stroke upper-limb rehabilitation and a new wireless sensor technology to enhance rehabilitation robotics based on the ZigBee network of wearable Inertial Measurement Units (IMU) and Surface Electromyography (sEMG) sensor nodes. These sensor nodes will allow the measurement of kinematic and electrical muscle activity of patients in continuous therapy motion over all body segments as a Body Sensor Network (BSN). The IMU Sensor design was based on a direction-cosine-matrix DCM. The system validation was achieved with an optical motion tracking system in which cameras and IMU sensors recorded upper limb positions simultaneously during a standard gesture of reaching and grasping. The comparison between elbow flexion-extension angle in reaching and grasping movements obtained from both techniques shows equivalence. The analysis of IMU data signals for several movements demonstrates high repeatability intra and inter-subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Application of inertial sensors in rehabilitation robotics
Rocon, E., Moreno, J. C., Ruiz, A. F., Brunetti, F., Miranda, J. A., & Pons, J. L. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428420 · Cited by 19
Cited by
Reviews on Various Inertial Measurement Unit (IMU) Sensor Applications
Ahmad, N., Ghazilla, R. A. R., Khairi, N. M., & Kasi, V. (2013) · International Journal of Signal Processing Systems · doi:10.12720/ijsps.1.2.256-262 · Cited by 406
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Improving the Accuracy of Human Body Orientation Estimation with Wearable IMU Sensors
Ahmed, H., & Tahir, M. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2016.2642658 · Cited by 87
Wang, H., Li, J., McDonald, B. E., Farrell, T. R., Huang, X., & Clancy, E. A. (2023) · Sensors · doi:10.3390/s23052465 · Cited by 18
Metadata
- Authors
- Cifuentes, C., Braidot, A., Rodriguez, L., Frisoli, M., Santiago, A., & Frizera, A.
- Venue
- 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob)
- Publisher
- IEEE
- Published
- 2012-06
- Pages
- 1989-1994
- ISSN
- 2155-1774 (ISSN-L)
- OpenAlex
- W2063470376
- Cited by
- 48
- References
- 1
- FWCI
- 8.40
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a wearable ZigBee sensor system for upper limb rehabilitation robotics. https://app.cochat.ai/papers/10.1109/biorob.2012.6290926
- The paper
- Cifuentes, C., Braidot, A., Rodriguez, L., Frisoli, M., Santiago, A., & Frizera, A. (2012). Development of a wearable ZigBee sensor system for upper limb rehabilitation robotics. 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob). https://doi.org/10.1109/biorob.2012.6290926
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.