Abstract

Microelectromechanical systems (MEMS) are revolutionizing a multitude of industries world wide, from consumer products to the scientific community. Rehabilitation robotics is a robotic field specially interested in using the advantages of inertial sensors. The essential aspect in this area is the intrinsic interaction between human and robot, which imposes several restrictions in the design of this sort of robots. This paper addresses the analysis of the application of inertial sensors as sensing technologies in controlled orthotic devices with a detailed analysis with two biomechatronic robotics rehabilitation exoskeletons, one for the upper and other for the lower limb. Eventually, the results and conclusion of the experiments are given.

Overview

Integrity signals

Registry

Crossref · 10.1109/icorr.2007.4428420

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 4

  1. rocon, 2005, On the use of rate gyroscopes for tremor sensing in the human upper limb, Proceedings of the International Conference Eurosensors XIX, mp30
  2. moreno, 2004, Intelligent knee-ankle-foot orthosis: The gait project approach, Rehabilitation Sciences in the New Millenium - Challenge for Multidisciplinary Research, 271
  3. 0, Vicon
  4. ferraris, 1995, Procedure for effortless infield calibration of three-axis rate gyros and accelerometers, Sensors and Materials, 7, 311

Cited by

See all 19

Metadata

Authors
Rocon, E., Moreno, J. C., Ruiz, A. F., Brunetti, F., Miranda, J. A., & Pons, J. L.
Affiliations
  • Consejo Superior de Investigaciones Científicas (ES)
  • Technaid (Spain) (ES)
Venue
2007 IEEE 10th International Conference on Rehabilitation Robotics
Publisher
IEEE
Published
2007-06
Pages
145-150
ISSN
1945-7898 (ISSN-L)
OpenAlex
W2011941009
Cited by
19
References
10
Citations by year
2025: 1 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 3 · 2015: 2 · 2013: 3 · 2012: 2
FWCI
1.53
Type
conference paper
Language
en
Open access
closed
Locations
International Conference on Rehabilitation Robotics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
inertial sensors, rehabilitation robotics, MEMS, rehabilitation exoskeleton, orthoses, human-robot interaction, upper limb exoskeleton, lower limb exoskeleton, biomechatronics, sensor technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of inertial sensors in rehabilitation robotics. https://app.cochat.ai/papers/10.1109/icorr.2007.4428420
The paper
Rocon, E., Moreno, J. C., Ruiz, A. F., Brunetti, F., Miranda, J. A., & Pons, J. L. (2007). Application of inertial sensors in rehabilitation robotics. 2007 IEEE 10th International Conference on Rehabilitation Robotics. https://doi.org/10.1109/icorr.2007.4428420

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.