Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Open accessAbstract
BACKGROUND: Wearable sensors are portable measurement tools that are becoming increasingly popular for the measurement of joint angle in the upper limb. With many brands emerging on the market, each with variations in hardware and protocols, evidence to inform selection and application is needed. Therefore, the objectives of this review were related to the use of wearable sensors to calculate upper limb joint angle. We aimed to describe (i) the characteristics of commercial and custom wearable sensors, (ii) the populations for whom researchers have adopted wearable sensors, and (iii) their established psychometric properties. METHODS: A systematic review of literature was undertaken using the following data bases: MEDLINE, EMBASE, CINAHL, Web of Science, SPORTDiscus, IEEE, and Scopus. Studies were eligible if they met the following criteria: (i) involved humans and/or robotic devices, (ii) involved the application or simulation of wearable sensors on the upper limb, and (iii) calculated a joint angle. RESULTS: Of 2191 records identified, 66 met the inclusion criteria. Eight studies compared wearable sensors to a robotic device and 22 studies compared to a motion analysis system. Commercial (n = 13) and custom (n = 7) wearable sensors were identified, each with variations in placement, calibration methods, and fusion algorithms, which were demonstrated to influence accuracy. CONCLUSION: Wearable sensors have potential as viable instruments for measurement of joint angle in the upper limb during active movement. Currently, customised application (i.e. calibration and angle calculation methods) is required to achieve sufficient accuracy (error < 5°). Additional research and standardisation is required to guide clinical application. TRIAL REGISTRATION: This systematic review was registered with PROSPERO ( CRD42017059935 ).
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Two systematic reviews have been conducted on the psychometric evidence relating to M/IMU validity.
“Two systematic reviews have been conducted to report on the psychometric evidence relating to M/IMU validity [11,12].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [11]
Walmsley et al.'s results for the upper limbs are in agreement with those presented in this review.
“Their results for the upper limbs are in agreement with those presented here.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823 · see citing works
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859 · see citing works
Mokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.02.006 · Cited by 4,465 · see citing works
The reliability of three-dimensional kinematic gait measurements: A systematic review
McGinley, J. L., Baker, R. J., Wolfe, R. S., & Morris, M. E. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.09.003 · Cited by 1,155 · see citing works
Foundations of Clinical Research
Portney, L. G., & Watkins, M. P. (1993) · Cited by 981 · see citing works
Clinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 901 · see citing works
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385 · see citing works
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369 · see citing works
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361 · see citing works
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356 · see citing works
Self-medication among medical and pharmacy students in Bangladesh
Alam, N., Saffoon, N., & Uddin, R. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1737-0 · Cited by 340 · see citing works
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329 · see citing works
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311 · see citing works
Fong, D. T.-P., & Chan, Y.-Y. (2010) · Sensors · doi:10.3390/s101211556 · Cited by 287 · see citing works
Shoulder and Elbow Joint Angle Tracking With Inertial Sensors
El‐Gohary, M., & McNames, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208750 · Cited by 264 · see citing works
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263 · see citing works
Use of multiple wearable inertial sensors in upper limb motion tracking
Zhou, H., Stone, T., Hu, H., & Harris, N. D. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.010 · Cited by 231 · see citing works
Movement biomechanics goes upwards: from the leg to the arm
Rau, G., Dißelhorst-Klug, C., & Schmidt, R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00062-2 · Cited by 215 · see citing works
Obituary: Yukio Mano (1943–2004)
Ikoma, K. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-1 · Cited by 173 · see citing works
Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method
Chapleau, J., Canet, F., Petit, Y., et al. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-1986-8 · Cited by 171 · see citing works
Inertial Sensor Technology for Elite Swimming Performance Analysis: A Systematic Review
Mooney, R., Corley, G. J., Godfrey, A., Quinlan, L. R., & OLaighin, G. M. (2015) · Sensors · doi:10.3390/s16010018 · Cited by 168 · see citing works
Human Joint Angle Estimation with Inertial Sensors and Validation with A Robot Arm
El‐Gohary, M., & McNames, J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2403368 · Cited by 167 · see citing works
Wearable inertial sensors in swimming motion analysis: a systematic review
Magalhães, F. A., Vannozzi, G., Gatta, G., et al. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.962574 · Cited by 164 · see citing works
Muir, S. W., Corea, C. L., & Beaupré, L. A. (2010) · PubMed · Cited by 163 · see citing works
Validation of Inertial Measurement Units for Upper Body Kinematics
Morrow, M. M. B., Lowndes, B. R., Fortune, E., Kaufman, K. R., & Hallbeck, M. S. (2016) · Journal of Applied Biomechanics · doi:10.1123/jab.2016-0120 · Cited by 152 · see citing works
Bouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133 · see citing works
Alignment-Free, Self-Calibrating Elbow Angles Measurement Using Inertial Sensors
Müller, P., Bégin, M.-A., Schauer, T., & Seel, T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2639537 · Cited by 114 · see citing works
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.02.029 · Cited by 108 · see citing works
Vries, W. H. K. D., Veeger, H. E. J., Cutti, A. G., Baten, C. T. M., & van der Helm, F. C. T. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.007 · Cited by 104 · see citing works
On Inertial Body Tracking in the Presence of Model Calibration Errors
Miezal, M., Taetz, B., & Bleser, G. (2016) · Sensors · doi:10.3390/s16071132 · Cited by 99 · see citing works
Estimation of Upper-Limb Orientation Based on Accelerometer and Gyroscope Measurements
Hyde, R. A., Ketteringham, L. P., Neild, S. A., & Jones, R. J. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912647 · Cited by 98 · see citing works
Pérez‐Rodríguez, R., Costa, U. M., Torrent, M., Sánchez, J. S., Opisso, E., Cáceres, C. A., Tormos, J. M., Medina-Casanovas, J., & Aguilera, E. J. G. (2010) · Sensors · doi:10.3390/s101210733 · Cited by 97 · see citing works
Gait analysis in children with cerebral palsy via inertial and magnetic sensors
van den Noort, J. C., Ferrari, A., Cutti, A. G., Becher, J. G., & Harlaar, J. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1006-5 · Cited by 93 · see citing works
Ubiquitous Human Upper-Limb Motion Estimation using Wearable Sensors
Zhang, Z., Wong, W., & Wu, J. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2159122 · Cited by 92 · see citing works
On the Orientation Error of IMU: Investigating Static and Dynamic Accuracy Targeting Human Motion
Ricci, L., Taffoni, F., & Formica, D. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161940 · Cited by 75 · see citing works
Fantozzi, S., Giovanardi, A., Magalhães, F. A., Di Michele, R., Cortesi, M., & Gatta, G. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1088659 · Cited by 74 · see citing works
Physical risk factors identification based on body sensor network combined to videotaping
Vignais, N., Bernard, F., Touvenot, G., et al. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.05.003 · Cited by 73 · see citing works
Outcome evaluation in shoulder surgery using 3D kinematics sensors
Coley, B., Jolles, B. M., Farron, A., Brégou, A., Nussbaumer, F., Pichonnaz, C., & Aminian, K. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.06.016 · Cited by 67 · see citing works
Repeatability of upper limb kinematics for children with and without cerebral palsy
Reid, S. L., Elliott, C. M., Alderson, J. A., et al. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.02.015 · Cited by 62 · see citing works
Self-citationMiniature Low-Power Inertial Sensors: Promising Technology for Implantable Motion Capture Systems
Lambrecht, J. M., & Kirsch, R. F. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2324825 · Cited by 62 · see citing works
Applications of wearable inertial sensors in estimation of upper limb movements
Zhou, H., Hu, H., Harris, N. D., et al. (2006) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2006.03.001 · Cited by 61 · see citing works
Upper limb joint angle tracking with inertial sensors
El‐Gohary, M., Holmstrom, L. A., Huisinga, J. M., King, E., McNames, J., & Horak, F. B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091362 · Cited by 56 · see citing works
Lin, H.-C., Chiang, S., Lee, K., et al. (2015) · Sensors · doi:10.3390/s150102181 · Cited by 54 · see citing works
Herrero, P., Carrera‐Lasfuentes, P., García, E. M., et al. (2011) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-12-155 · Cited by 53 · see citing works
Upper limb joint angle measurement in occupational health
Álvarez, D., Alvarez, J. C., González, R. C., & López, A. M. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.997718 · Cited by 53 · see citing works
A novel 7 degrees of freedom model for upper limb kinematic reconstruction based on wearable sensors
Peppoloni, L., Filippeschi, A., Ruffaldi, E., & Avizzano, C. A. (2013) · IEEE International Symposium on Intelligent Systems and Informatics (SISY) · doi:10.1109/sisy.2013.6662551 · Cited by 51 · see citing works
Conducting Precision Medicine Research with African Americans
Halbert, C. H., McDonald, J. A., Vadaparampil, S. T., Rice, L., & Jefferson, M. S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154850 · Cited by 50 · see citing works
Development of a wearable ZigBee sensor system for upper limb rehabilitation robotics
Cifuentes, C. A., Braidot, A. A. A., Rodriguez, L., Frisoli, M. A., Santiago, A., & Frizera, A. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290926 · Cited by 48 · see citing works
Ligorio, G., Zanotto, D., Sabatini, A. M., & Agrawal, S. K. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.01.024 · Cited by 46 · see citing works
dos Santos, C. M., Ferreira, G., Malacco, P. L., et al. (2012) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922012000100008 · Cited by 45 · see citing works
A Smartphone-Centric System for the Range of Motion Assessment in Stroke Patients
Lee, W. W., Yen, S., Tay, A. E., Zhao, Z., Xu, T., Ling, K. K. M., Ng, Y. S., Chew, E., Cheong, A., & Huat, G. K. C. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2301449 · Cited by 41 · see citing works
Age-related changes analyzing shoulder kinematics by means of inertial sensors
Roldán‐Jiménez, C., & Cuesta‐Vargas, A. (2016) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2016.06.004 · Cited by 41 · see citing works
Application of a Full Body Inertial Measurement System in Dressage Riding
Eckardt, F., Münz, A., & Witte, K. (2014) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2014.09.009 · Cited by 40 · see citing works
Kinematic Analysis of the Rider According to Different Skill Levels in Sitting Trot and Canter
Eckardt, F., & Witte, K. (2015) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2015.07.022 · Cited by 38 · see citing works
Design and validation of an ambulatory inertial system for 3-D measurements of low back movements
Charry, E., Umer, M., & Taylor, S. B. (2011) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2011.6146618 · Cited by 37 · see citing works
Estimation of Human Arm Joints Using Two Wireless Sensors in Robotic Rehabilitation Tasks
Bertomeu-Motos, A., Lledó, L. D., Díez, J., Catalan, J. M., Ezquerro, S., Badesa, F. J., & García-Aracil, N. (2015) · Sensors · doi:10.3390/s151229818 · Cited by 37 · see citing works
Callejas-Cuervo, M., Gutiérrez, R. M., & Hernandez, A. I. (2016) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2016.08.016 · Cited by 33 · see citing works
Detecting Elementary Arm Movements by Tracking Upper Limb Joint Angles With MARG Sensors
Mazomenos, E. B., Biswas, D., Cranny, A., Rajan, A., Maharatna, K., Achner, J., Klemke, J., Jöbges, M., Ortmann, S., & Langendörfer, P. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2431472 · Cited by 32 · see citing works
Schiefer, C., Kraus, T., Ellegast, R. P., & Ochsmann, E. (2015) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-015-0058-5 · Cited by 31 · see citing works
Matsumoto, H., Ueki, M., UEHARA, K., et al. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/5963432 · Cited by 31 · see citing works
Rose, M., Curtze, C., O'Sullivan, J., et al. (2017) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2017.06.042 · Cited by 31 · see citing works
A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs.
Gil-Agudo, A. M., Reyes-Guzmán, A. D. L., Dimbwadyo-Terrer, I., Peñasco-Martín, B., Bernal-Sahún, A., López-Monteagudo, P., del‐Ama, A. J., & Pons, J. L. (2013) · PubMed Central · doi:10.3969/j.issn.1673-5374.2013.19.005 · Cited by 30 · see citing works
Joint angle tracking with inertial sensors
El‐Gohary, M., Pearson, S., & McNames, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649344 · Cited by 30 · see citing works
Kirking, B., El‐Gohary, M., & Kwon, Y.-H. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.06.008 · Cited by 30 · see citing works
Kumar, Y., Yen, S., Tay, A. E., Lee, W., Gao, F., Zhao, Z., Li, J., Hon, B., Xu, T., Cheong, A., et al. (2015) · Healthcare Technology Letters · doi:10.1049/htl.2014.0100 · Cited by 28 · see citing works
Motor impairment evaluation for upper limb in stroke patients on the basis of a microsensor
Huang, S., Luo, C., Ye, S., Liu, F., Xie, B., Wang, C., Yang, L., Huang, Z., & Wu, J. (2012) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0b013e328353053a · Cited by 28 · see citing works
Assessment of task ergonomics with an upper limb wearable device
Peppoloni, L., Filippeschi, A., & Ruffaldi, E. (2014) · 2006 14th Mediterranean Conference on Control and Automation · doi:10.1109/med.2014.6961394 · Cited by 27 · see citing works
Miguel‐Andrés, I., Alonso‐Rasgado, T., Walmsley, A., et al. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1715-2 · Cited by 27 · see citing works
Classification and legality analysis of bowling action in the game of cricket
Salman, M., Qaisar, S., & Qamar, A. M. (2017) · Data Mining and Knowledge Discovery · doi:10.1007/s10618-017-0511-4 · Cited by 27 · see citing works
Application of low cost inertial sensors to human motion analysis
Bai, L., Pepper, M., Yana, Y., et al. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229349 · Cited by 25 · see citing works
An adaptive complementary filter for inertial sensor based data fusion to track upper body motion
Karunarathne, M. S., Ekanayake, S. W., & Pathirana, P. N. (2014) · International Conference on Information and Automation for Sustainability (ICIAfS) · doi:10.1109/iciafs.2014.7069606 · Cited by 23 · see citing works
Development of an upper limb rehabilitation system using inertial movement units and kinect device
Chen, P.-J., Du, Y., Shih, C.-B., et al. (2016) · doi:10.1109/icamse.2016.7840309 · Cited by 18 · see citing works
Development of IMU-based angle measurement system for finger rehabilitation
Chang, H.-T., Cheng, L.-W., & Chang, J.-Y. J. (2016) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip.2016.7827295 · Cited by 16 · see citing works
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
Ruiz-Olaya, A. F., Callejas-Cuervo, M., & Lara-Herrera, C. N. (2017) · DYNA · doi:10.15446/dyna.v84n201.59054 · Cited by 16 · see citing works
A multi-parameter assessment tool for upper limb motion in neurorehabilitation
Bai, L., Pepper, M., Yan, Y. G., Spurgeon, S. K., Sakel, M., & Phillips, M. (2011) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/imtc.2011.5944169 · Cited by 13 · see citing works
A single task assessment system of upper-limb motor function after stroke
Li, J., Pan, B., Jin, T., Huang, Z., Ye, S., Wu, J., Huang, Z., Xie, B., Luo, C., & Wang, C. (2016) · Technology and Health Care · doi:10.3233/thc-161199 · Cited by 13 · see citing works
Studying upper-limb kinematics using inertial sensors: a cross-sectional study
Roldán‐Jiménez, C., & Cuesta‐Vargas, A. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1517-x · Cited by 12 · see citing works
3D Upper Limb Motion Modeling and Estimation Using Wearable Micro-sensors
Zhang, Z., Wong, L. W. C., & Wu, J. (2010) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2010.14 · Cited by 11 · see citing works
Watanabe, K., Morishita, H., Mori, T., et al. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.364116 · Cited by 11 · see citing works
Ricci, L., Formica, D., Tamilia, E., et al. (2013) · doi:10.1109/embc.2013.6610647 · Cited by 9 · see citing works
Ambulatory human upper limb joint motion monitoring
Álvarez, D., Alvarez, J. C., González, R. C., & López, A. M. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229695 · Cited by 7 · see citing works
Development of a wireless sensor network for the measurement of human joint angles
Meng, D., & Vejarano, G. (2013) · International Conference on Connected Vehicles and Expo · doi:10.1109/iccve.2013.6799820 · Cited by 7 · see citing works
Design of human motion detection based on the human body communication
Gao, Y., Zhang, L., Du, M., et al. (2015) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2015.7373143 · Cited by 7 · see citing works
A measurement system for wrist movements in biomedical applications
Borbély, B. J., Tihanyi, A., & Szolgay, P. (2015) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2015.7300047 · Cited by 6 · see citing works
A Human Motion Capture System Based on Inertial Sensing and a Complementary Filter
Kanjanapas, K., Wang, Y., Zhang, W., et al. (2013) · doi:10.1115/dscc2013-3852 · Cited by 6 · see citing works
Pressure and kinematic in-suit sensors: Assessing human-suit interaction for injury risk mitigation
Bertrand, P. M., Reyes, S., & Newman, D. J. (2016) · Proceedings - IEEE Aerospace Conference · doi:10.1109/aero.2016.7500699 · Cited by 6 · see citing works
User wearable interface based on inertial sensors for unilateral master-slave robot teleoperation
Rodríguez-Ángeles, A., Guzman-Gutierrez, J. L., & Cruz-Villar, C. A. (2010) · International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE) · doi:10.1109/iceee.2010.5608665 · Cited by 5 · see citing works
Prediction of received signal strength from human joint angles in body area networks
Tran, T. M., & Vejarano, G. (2016) · 2012 International Conference on Computing, Networking and Communications (ICNC) · doi:10.1109/iccnc.2016.7440700 · Cited by 5 · see citing works
Quiñones-Urióstegui, I., Bernal-Yescas, F., Tovar-Sandoval, J. A., et al. (2014) · Pan American Health Care Exchanges · doi:10.1109/pahce.2014.6849643 · Cited by 4 · see citing works
DAUNORAVIČENĖ, K., Linkel, A., Žižienė, J., et al. (2017) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519417500804 · Cited by 4 · see citing works
Balbinot, A., de Freitas, J. C. R., & Côrrea, D. S. (2015) · Health and Technology · doi:10.1007/s12553-015-0110-6 · Cited by 3 · see citing works
Eom, S.-H., & Lee, E.-H. (2016) · Technology and Health Care · doi:10.3233/thc-161188 · Cited by 2 · see citing works
Effects of wrist kinematic coupling movements during dart-thrower's motion
Nguyen, N. D., Pham, T. H., Mahani, T., et al. (2016) · doi:10.1109/wecon.2016.7993486 · Cited by 2 · see citing works
Bruyneel, A.-V. (2018) · Kinésithérapie la Revue · doi:10.1016/j.kine.2018.01.011 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable health devices in health care: narrative systematic review
Lu, L., Zhang, J., Xie, Y., Gao, F., Xu, S., Wu, X., & Ye, Z. (2020) · JMIR mHealth and uHealth · doi:10.2196/18907 · Cited by 701 · see citing works
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Hughes, C. M. L., Louie, A., Sun, S., Gordon-Murer, C., Belay, G. J., Baye, M., & Zhang, X. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00322 · Cited by 25 · see citing works
Enhancing accuracy and convenience of golf swing tracking with a wrist-worn single inertial sensor
Kim, M., & Park, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-59949-w · Cited by 14 · see citing works
- Authors
- Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A.
- Affiliations
- Curtin University (AU)
- University of Auckland (NZ)
- Australian Catholic University (AU)
- Corresponding author
- Imms, Christine
- ORCID
- Venue
- Sports Medicine - Open
- Published
- 2018-11-29
- Volume
- 4
- Issue
- 1
- Pages
- 53-53
- ISSN
- 2198-9761 (ISSN-L)
- 2199-1170
- PMC
- PMC6265374
- OpenAlex
- W2902349279
- Cited by
- 123
- References
- 94
- Citations by year
- 2026: 10 · 2025: 19 · 2024: 17 · 2023: 17 · 2022: 19 · 2021: 16 · 2020: 16 · 2019: 8 · 2018: 1
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sports Medicine - Open (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Research Bank (Australian Catholic University) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- eSpace (Curtin University) (submittedVersion, cc-by)
- Minerva Access (University of Melbourne) (submittedVersion, cc-by)
- ResearchSpace (University of Auckland) (submittedVersion, cc-by)
- Funders
- Australian Government Research Training Program Scholarship
- Perth Children's Hospital Foundation
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Rehabilitation › Musculoskeletal Disorders and Rehabilitation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- wearable sensors, upper limb range of motion, joint angle measurement, sensor calibration, sensor fusion algorithms, psychometric properties, measurement accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review