Feasibility of Imaging Photoplethysmography
Open accessThe DOI matches its Crossref record.
Abstract
Contact and spot measurement have limited the application of photoplethysmography (PPG), thus an imaging PPG system comprising a digital CMOS camera and three wavelength light-emitting diodes (LEDs) is developed to detect the blood perfusion in tissue. With the means of the imaging PPG system, the ideally contactless monitoring with larger field of view and the different depth of tissue by applying multi- wavelength illumination can be achieved to understand the blood perfusion change. Corresponding to the individual wavelength LED illumination, the PPG signals can be derived in the both transmission and reflection modes, respectively. The outcome explicitly reveals the imaging PPG is able to detect blood perfusion in a illuminated tissue and indicates the vascular distribution and the blood cell response to individual wavelength LED. The functionality investigation leads to the engineering model for 3-D visualized blood perfusion of tissue and the development of imaging PPG tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“Plethysmographic signals can be measured remotely (>1 m) using ambient light and PD with either a simple consumer-level digital camera in movie mode or a cellular phone [11,44–46].”
MethodHow accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Aarts, L. A. M., Jeanne, V., Cleary, J. P., Lieber, C., Nelson, J. S., Bambang Oetomo, S., & Verkruysse, W. (2013) · Early Human Development · doi:10.1016/j.earlhumdev.2013.09.016 · Cited by 241
“Recently, camera based PPG was demonstrated [9–17].”
Remote Measurements of Heart and Respiration Rates for Telemedicine
Zhao, F., Li, M., Qian, Y., & Tsien, J. Z. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071384 · Cited by 189
Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time
Shao, D., Yang, Y., Liu, C., Tsow, F., Yu, H., & Tao, N. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2327024 · Cited by 183
“Heart and breathing rates were obtained from the images of faces [10], [11], upper arms [12], and palms [13] recorded with digital cameras, including smartphone cameras [14] and webcams.”
MethodAmbient and Unobtrusive Cardiorespiratory Monitoring Techniques
Bruser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
Remote PPG based vital sign measurement using adaptive facial regions
Tasli, H. E., Gudi, A., & den Uyl, M. (2014) · 2014 IEEE International Conference on Image Processing (ICIP) · doi:10.1109/icip.2014.7025282 · Cited by 99
“Moreover, recent methods for remotely measuring these periodic changes have been proposed [1], [2].”
Method
Metadata
- Authors
- Zheng, J., Hu, S., Chouliaras, V., & Summers, R.
- Venue
- 2008 International Conference on BioMedical Engineering and Informatics
- Publisher
- IEEE
- Published
- 2008-05
- Pages
- 72-75
- OpenAlex
- W2111960136
- Cited by
- 80
- References
- 0
- FWCI
- 8.00
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.