The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
HealthGear: A Real-time Wearable System for Monitoring and Analyzing Physiological Signals
Abstract
We present HealthGear, a real-time wearable system for monitoring, visualizing and analyzing physiological signals. HealthGear consists of a set of noninvasive physiological sensors wirelessly connected via Bluetooth to a cell phone which stores, transmits and analyzes the physiological data, and presents it to the user in an intelligible way. In this paper, we focus on an implementation of HealthGear using a blood oximeter to monitor the user's blood oxygen level and pulse while sleeping. We also describe two different algorithms for automatically detecting sleep apnea events, and illustrate the performance of the overall system in a sleep study with 20 volunteers
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Least-squares frequency analysis of unequally spaced data
Lomb, N. R. (1976) · Astrophysics and Space Science · doi:10.1007/bf00648343 · Cited by 5,717
Jovanov, E., Milenkovic, A., Otto, C., & de Groen, P. C. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-6 · Cited by 1,013
CodeBlue: An Ad Hoc Sensor Network Infrastructure for Emergency Medical Care
Malan, D. J., Fulford-Jones, T. R. F., Welsh, M., & Moulton, S. (2004) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 798
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707
Enhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 614
Snoring as a risk factor for ischaemic heart disease and stroke in men.
Koskenvuo, M., Kaprio, J., Telakivi, T., Partinen, M., Heikkila, K., & Sarna, S. (1987) · BMJ · doi:10.1136/bmj.294.6563.16 · Cited by 483
The Medical Cost of Undiagnosed Sleep Apnea
Kapur, V., Blough, D. K., Sandblom, R. E., Hert, R., de Maine, J. B., Sullivan, S. D., & Psaty, B. M. (1999) · Sleep · doi:10.1093/sleep/22.6.749 · Cited by 384
Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
Vazquez, J.-C. (2000) · Thorax · doi:10.1136/thorax.55.4.302 · Cited by 254
Martin, T., Jovanov, E., & Raskovic, D. (2002) · Digest of Papers. Fourth International Symposium on Wearable Computers · doi:10.1109/iswc.2000.888463 · Cited by 234
Mobile Patient Monitoring: the MobiHealth System
Dimitri, K., Aart, V. H., Richard, B., Katarzyna, W., Ing, W., Nicolai, D., George, K., Val, J., & Rainer, H. (2004) · Studies in Health Technology and Informatics · doi:10.3233/978-1-60750-946-2-307 · Cited by 200
Sleep Apnea and Periodic Movements in an Aging Sample
Ancoli-israel, S., Kripke, D. F., Mason, W., & Kaplan, O. J. (1985) · Journal of Gerontology · doi:10.1093/geronj/40.4.419 · Cited by 199
Series, F., Marc, I., Cormier, Y., & La Forge, J. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-6-199309150-00001 · Cited by 196
Accuracy of Oximetry for Detection of Respiratory Disturbances in Sleep Apnea Syndrome
Lévy, P., Louis Pépin, J., Deschaux-Blanc, C., Paramelle, B., & Brambilla, C. (1996) · Chest · doi:10.1378/chest.109.2.395 · Cited by 188
Screening for Sleep Apnea Using Pulse Oximetry and A Clinical Score
Williams, A. J., Yu, G. W., Santiago, S., & Stein, M. (1991) · CHEST Journal · doi:10.1378/chest.100.3.631 · Cited by 155
Wearable health care system for vital signs monitoring
Paradiso, R. (2003) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2003.1222533 · Cited by 109
Zamarrón, C., Gudé, F., González‐Barcala, F. J., Rodriguez, J. R., & Romero, P. V. (2003) · CHEST Journal · doi:10.1378/chest.123.5.1567 · Cited by 107
Analysis and characterization of photo-plethysmographic signal
Bhattacharya, J., Kanjilal, P. P., & Muralidhar, V. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.900243 · Cited by 68
Snoring as a risk factor for ischemic heart disease and stroke in men.
Yates, P. (1987) · BMJ · doi:10.1136/bmj.294.6568.371-b · Cited by 50
Husemann, D., Narayanaswa, C., & Nidd, M. (2004) · International Symposium on Wearable Computers · doi:10.1109/iswc.2004.35 · Cited by 34
Cheng, P.-T., Tsai, L.-M., Lu, L.-W., & Yang, D. (2004) · IEEE International Conference on Computer and Information Technology (CIT) · doi:10.1109/cit.2004.1357306 · Cited by 26
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Security and Privacy Issues in Wireless Sensor Networks for Healthcare Applications
Al Ameen, M., Liu, J., & Kwak, K. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9449-4 · Cited by 651
Wireless body sensor networks for health-monitoring applications
Hao, Y., & Foster, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/11/r01 · Cited by 404
Sensor Positioning for Activity Recognition Using Wearable Accelerometers
Atallah, L., Lo, B., King, R., & Yang, G.-Z. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2160540 · Cited by 346
Metadata
- Authors
- Oliver, N., & Flores-Mangas, F.
- Venue
- International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06)
- Publisher
- IEEE
- Published
- 2006-04-28
- Pages
- 61-64
- OpenAlex
- W2134643721
- Cited by
- 255
- References
- 21
- FWCI
- 25.64
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.