Respiratory Rate and Flow Waveform Estimation from Tri-axial Accelerometer Data
Abstract
There is a strong medical need for continuous, unobstrusive respiratory monitoring, and many shortcomings to existing methods. Previous work shows that MEMS accelerometers worn on the torso can measure inclination changes due to breathing, from which a respiratory rate can be obtained. There has been limited validation of these methods. The problem of practical continuous monitoring, in which patient movement disrupts the measurements and the axis of interest changes, has also not been addressed. We demonstrate a method based on tri-axial accelerometer data from a wireless sensor device, which tracks the axis of rotation and obtains angular rates of breathing motion. The resulting rates are validated against gyroscope measurements and show high correlation to flow rate measurements using a nasal cannula. We use a movement detection method to classify periods in which the patient is static and breathing signals can be observed accurately. Within these periods we obtain a close match to cannula measurements, for both the flow rate waveform and derived respiratory rates, over multi-hour datasets obtained from wireless sensor devices on hospital patients. We discuss future directions for improvement and potential methods for estimating absolute airflow rate and tidal volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Estimation of Respiration Rate from Three-Dimensional Acceleration Data Based on Body Sensor Network
Liu, G.-Z., Guo, Y.-W., Zhu, Q.-S., Huang, B.-Y., & Wang, L. (2011) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0022 · Cited by 107
Medical Devices for Measuring Respiratory Rate in Children: a Review
Daw, W. (2016) · Journal of Advances in Biomedical Engineering and Technology · doi:10.15379/2409-3394.2016.03.01.04 · Cited by 35
“Another similar device, the Orient speck [20], has also been developed which acts in a similar way to the HealthPatch MD.”
Metadata
- Authors
- Bates, A., Ling, M. J., Mann, J., & Arvind, D. K.
- Venue
- 2010 International Conference on Body Sensor Networks
- Publisher
- IEEE
- Published
- 2010-06
- Pages
- 144-150
- OpenAlex
- W2020624939
- Cited by
- 163
- References
- 0
- FWCI
- 16.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory Rate and Flow Waveform Estimation from Tri-axial Accelerometer Data. https://app.cochat.ai/papers/10.1109/bsn.2010.50
- The paper
- Bates, A., Ling, M. J., Mann, J., & Arvind, D. K. (2010). Respiratory Rate and Flow Waveform Estimation from Tri-axial Accelerometer Data. 2010 International Conference on Body Sensor Networks. https://doi.org/10.1109/bsn.2010.50
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.