Cited by 29Context-Aware Activity Recognition SystemsWireless Body Area NetworksNon-Invasive Vital Sign Monitoring

Unsupervised deep representation learning to remove motion artifacts in free-mode body sensor networks

Mohammed, Shoaib, Tashev, Ivan·2017·2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN)

Abstract

In body sensor networks, the need to brace sensing devices firmly to the body raises a fundamental barrier to usability. In this paper, we examine the effects of sensing from devices that do not face this mounting limitation. With sensors integrated into common pieces of clothing, we demonstrate that signals in such free-mode body sensor networks are contaminated heavily with motion artifacts leading to mean signal-to-noise ratios (SNRs) as low as -12 dB. Further, we show that motion artifacts at these SNR levels reduce the F1-score of a state-of-the-art algorithm for human-activity recognition by up to 77.1%. In order to mitigate these artifacts, we evaluate the use of statistical (Kalman Filters) and data-driven (Neural Networks) techniques. We show that well-designed methods of representing IMU data with deep neural networks can increase SNRs in free-mode body-sensor networks from -12 dB to +18.2 dB and, as a result, improve the F1-score of recognizing gestures by 14.4% and locomotion activities by 55.3%.

Integrity signals

Registry

Crossref · 10.1109/bsn.2017.7936037

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Autoencoders are commonly used to sanitize and denoise raw sensor data, a known problem with wearable signals that impacts the ability to learn patterns in the data.

    “Furthermore, autoencoders are commonly used to sanitize and denoise raw sensor data [127,130,148], a known problem with wearable signals that impacts our ability to learn patterns in the data.”
  • The DSTSAE outperforms traditional Kalman Filters and improves the SNR from −12 dB to +18.2 dB, with the F1-score of recognizing gestures improved by 14.4% and locomotion activities by 55.3%.

    “Experiments show that the DSTSAE outperforms traditional Kalman Filters and improves the SNR from −12 dB to +18.2 dB, with the F1-score of recognizing gestures improved by 14.4% and locomotion activities by 55.3%.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Mohammed, S., & Tashev, I.
Affiliations
Microsoft (United States) (US)
Venue
2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN)
Publisher
IEEE
Published
2017-05
Pages
183-188
ISSN
2376-8886 (ISSN-L)
OpenAlex
W2605049121
Cited by
29
References
21
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 4 · 2019: 2 · 2018: 9
FWCI
1.20
Type
conference paper
Language
en
Open access
closed
Locations
Wearable and Implantable Body Sensor Networks (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
motion artifact removal, wearable sensors, IMU data, human activity recognition, gesture recognition, signal-to-noise ratio, Kalman filter, artificial neural networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review