Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 198

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A new QRS detection algorithm based on the Hilbert transform

Benitez, D.S., Gaydecki, P.A., Zaidi, A., Fitzpatrick, A.P. · 2002 · Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163)

Abstract

A robust new algorithm for QRS defection using the properties of the Hilbert transform is proposed. The method allows R waves to be differentiated from large, peaked T and P waves with a high degree of accuracy and minimizes the problems associated with baseline drift, motion artifacts and muscular noise. The performance of the algorithm was tested using the records of the MIT-BIH Arrhythmia Database. Beat by beat comparison was performed according to the recommendation of the American National Standard for ambulatory ECG analyzers (ANSI/AAMI EC38-1998). A QRS detection rate of 99.64%, a sensitivity of 99.81% and a positive prediction of 99.83% was achieved against the MIT-BIH Arrhythmia database. The noise tolerance of the new proposed QRS detector was also tested using standard records from the MIT-BIH Noise Stress Test Database. The sensitivity of the detector remains about 94% even for signal-to-noise ratios (SNR) as low as 6 dB.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/cic.2000.898536

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 198

Metadata

Authors
Benitez, D. S., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P.
Venue
Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163)
Publisher
IEEE
Published
2002-11-11
Pages
379-382
ISSN
0276-6574 (ISSN-L)
OpenAlex
W2154924564
Cited by
198
References
2
FWCI
5.48
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.