CoChat

Tremor Suppression of Elbow Joint via Functional Electrical Stimulation: A Simulation Study

Zhang, Dingguo, Ang, Wei · 2006 · 2006 IEEE International Conference on Automation Science and Engineering
Cited by 32

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In this paper, we propose a 1-DOF musculoskeletal model of the elbow joint that consists of a pair of antagonist muscles and one skeleton. Simulation based on the proposed model is performed to study the feasibility of tremor suppression via functional electrical stimulation (FES). In order to effectively attenuate pathological tremor of the movement disorder patients with minimal effect in the voluntary movement, we propose a fuzzy logical controller (FLC), a proportional-derivative (PD) controller and a compensator to regulate the stimulator. Current simulation results have shown satisfactory performance for the postural tremor suppression

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/coase.2006.326877

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Attenuation of pathological tremors by functional electrical stimulation I: Method

    Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 2×

    “The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
    BackgroundMethod
  • Modeling and canceling tremor in human-machine interfaces

    Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×

    “The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
    Method
  • Dynamically responsive intervention for tremor suppression

    Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 1×

    “The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
    Method
  • Optimal digital filtering for tremor suppression

    Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56 · cited 1×

    “The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
    Method

Cited by

See all 32

Metadata

Authors
Zhang, D., & Ang, W.
Venue
2006 IEEE International Conference on Automation Science and Engineering
Publisher
IEEE
Published
2006
Pages
182-187
ISSN
2161-8070 (ISSN-L)
OpenAlex
W2107704976
Cited by
32
References
4
FWCI
5.40
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.