Tremor Suppression of Elbow Joint via Functional Electrical Stimulation: A Simulation Study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this paper, we propose a 1-DOF musculoskeletal model of the elbow joint that consists of a pair of antagonist muscles and one skeleton. Simulation based on the proposed model is performed to study the feasibility of tremor suppression via functional electrical stimulation (FES). In order to effectively attenuate pathological tremor of the movement disorder patients with minimal effect in the voluntary movement, we propose a fuzzy logical controller (FLC), a proportional-derivative (PD) controller and a compensator to regulate the stimulator. Current simulation results have shown satisfactory performance for the postural tremor suppression
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 2×
“The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
BackgroundMethodModeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×
“The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
MethodDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 1×
“The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
MethodOptimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56 · cited 1×
“The assistive technique functions in two forms: (i) to suppress the tremor at the man-machine interface [3], [5], [6], and (ii) to attenuate the tremor actively and directly at the limbs [2], [4].”
Method
Cited by
Zhang, D., Poignet, P., Widjaja, F., & Tech Ang, W. (2011) · Control Engineering Practice · doi:10.1016/j.conengprac.2010.08.009 · Cited by 88
Self-citationRepetitive Control of Electrical Stimulation for Tremor Suppression
Copur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2019) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2017.2771327 · Cited by 38
Repetitive control of functional electrical stimulation for induced tremor suppression
Freeman, C. T., Sampson, P., Burridge, J. H., & Hughes, A.-M. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.10.008 · Cited by 31
Bioinformatic Approaches Used in Modelling Human Tremor
Mario, M., Giuliana, G., Thomas, L., Dario, F., Lana, P., Silvia, C., Tommaso, D., Juan-Manuel, B.-L., Jose-Luis, P., & Eduardo, R. (2009) · Current Bioinformatics · doi:10.2174/157489309788184747 · Cited by 17
FES based tremor suppression using repetitive control
Copur, E. H., Freeman, C., Chu, B., & Laila, D. S. (2015) · 2015 54th IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2015.7403166 · Cited by 4
“In [5], a fuzzy logic controller combined with a ProportionalDerivative (PD) controller was developed.”
Method
Metadata
- Authors
- Zhang, D., & Ang, W.
- Venue
- 2006 IEEE International Conference on Automation Science and Engineering
- Publisher
- IEEE
- Published
- 2006
- Pages
- 182-187
- ISSN
- 2161-8070 (ISSN-L)
- OpenAlex
- W2107704976
- Cited by
- 32
- References
- 4
- FWCI
- 5.40
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.