CoChat

FES based tremor suppression using repetitive control

Open access
Copur, Engin H., Freeman, Christopher, Chu, Bing, Laila, Dina S. · 2015 · 2015 54th IEEE Conference on Decision and Control (CDC)

The DOI matches its Crossref record; 20 of the 22 references it cites were found in a registry or an index.

Abstract

Tremor is a neurological condition present in half of all multiple sclerosis and Parkinson cases, resulting in involuntary, debilitating movement oscillations. Functional electrical stimulation (FES) can be used to suppress tremor, but current approaches using classical control methods have shown significant limitations. This paper establishes the feasibility of using repetitive control (RC), giving rise to the first FES control structure that embeds learning from experience for the purpose of suppressing tremor. The paradigm is applied to suppress tremor at the wrist via FES regulated co-contraction of wrist extensors/flexors. Experimental evaluation is performed using a validated wrist-rig and results are compared against classical feedback control design to establish the efficacy of the approach.

Overview

Integrity signals

Registry

Crossref · 10.1109/cdc.2015.7403166

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 20 references

Research works printed but not linked: 4

  1. chen, 2002, Stability issues using FIR filtering in repetitive control, Adv Astronaut Sci, 112, 1321
  2. 10.1007/bf02368521 · DOI · Paper page
  3. 2008, Multiple sclerosis resources in the world 2008, World Health Organization and Multiple Sclerosis International Federation Tech Rep
  4. freriks, 1999, SE-NIAM 8: European Recommendations for Surface ElectroMyoGraphy, Roessingh Res Develop

Cited by

See all 4

Metadata

Authors
Copur, E. H., Freeman, C., Chu, B., & Laila, D. S.
Affiliations
University of Southampton (GB)
Venue
2015 54th IEEE Conference on Decision and Control (CDC)
Publisher
IEEE
Published
2015-12
Volume
112
Pages
6023-6028
ISSN
0191-2216 (ISSN-L)
OpenAlex
W2240765111
Cited by
4
References
22
Citations by year
2025: 1 · 2021: 1 · 2019: 1 · 2017: 1
FWCI
0.47
Type
conference paper
Language
en
Licence
other-oa
Locations
  • IEEE Conference on Decision and Control (CDC) (publishedVersion)
  • ePrints Soton (University of Southampton) (acceptedVersion)
  • Coventry University Open Collections (Coventry university) (submittedVersion)
  • Pure (Coventry University) (submittedVersion, other-oa)
  • The Open Collections (Coventry University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Iterative Learning Control Systems
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
Keywords
tremor suppression, functional electrical stimulation, repetitive control, Parkinson's disease, multiple sclerosis, learning control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: FES based tremor suppression using repetitive control. https://app.cochat.ai/papers/10.1109/cdc.2015.7403166
The paper
Copur, E. H., Freeman, C., Chu, B., & Laila, D. S. (2015). FES based tremor suppression using repetitive control. 2015 54th IEEE Conference on Decision and Control (CDC). https://doi.org/10.1109/cdc.2015.7403166

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.