The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Remote Heart Rate Measurement from Face Videos under Realistic Situations
Abstract
Heart rate is an important indicator of people's physiological state. Recently, several papers reported methods to measure heart rate remotely from face videos. Those methods work well on stationary subjects under well controlled conditions, but their performance significantly degrades if the videos are recorded under more challenging conditions, specifically when subjects' motions and illumination variations are involved. We propose a framework which utilizes face tracking and Normalized Least Mean Square adaptive filtering methods to counter their influences. We test our framework on a large difficult and public database MAHNOB-HCI and demonstrate that our method substantially outperforms all previous methods. We also use our method for long term heart rate monitoring in a game evaluation scenario and achieve promising results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
Haykin, S. (1986) · Cited by 12,603
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
Rogers, S. (1996) · Control Engineering Practice · doi:10.1016/0967-0661(96)82838-3 · Cited by 9,278
Shi, J., & Tomasi (1994) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition CVPR-94 · doi:10.1109/cvpr.1994.323794 · Cited by 7,724 · cited 1×
“[15], and are tracked through the following frames using the Kanade-Lucas-Tomasi (KLT) algorithm [19].”
MethodBradski, G. R. (2000) · Medical Entomology and Zoology · Cited by 5,994
Detection and Tracking of Point Features
Tomasi, C. (1991) · Cited by 2,231
Distance Regularized Level Set Evolution and Its Application to Image Segmentation
Li, C., Xu, C., Gui, C., & Fox, M. D. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2069690 · Cited by 2,106
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
A Multimodal Database for Affect Recognition and Implicit Tagging
Soleymani, M., Lichtenauer, J., Pun, T., & Pantic, M. (2012) · IEEE Transactions on Affective Computing · doi:10.1109/t-affc.2011.25 · Cited by 1,664
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Lambertian reflectance and linear subspaces
Basri, R., & Jacobs, D. W. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1177153 · Cited by 1,576
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
An advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,131
Optical absorption of hemoglobin
Prahl, S. A. (1999) · Medical Entomology and Zoology · Cited by 579
Robust Discriminative Response Map Fitting with Constrained Local Models
Asthana, A., Zafeiriou, S., Cheng, S., & Pantic, M. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.442 · Cited by 557
Detecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.440 · Cited by 553
Validity of the Polar S810 Heart Rate Monitor to Measure R-R Intervals at Rest
GAMELIN, F. X., BERTHOIN, S., & BOSQUET, L. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218135.79476.9c · Cited by 509
Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone
Kwon, S., Kim, H., & Park, K. S. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346392 · Cited by 245
Humphreys, K., Ward, T., & Markham, C. (2007) · Review of Scientific Instruments · doi:10.1063/1.2724789 · Cited by 217
Heart rate monitoring via remote photoplethysmography with motion artifacts reduction
Cennini, G., Arguel, J., Akşit, K., & van Leest, A. J. (2010) · Optics Express · doi:10.1364/oe.18.004867 · Cited by 111
Chan, K. W., & Zhang, Y. (2003) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2002.1037314 · Cited by 103
Cited by
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Metadata
- Authors
- Li, X., Chen, J., Zhao, G., & Pietikainen, M.
- Venue
- 2014 IEEE Conference on Computer Vision and Pattern Recognition
- Publisher
- IEEE
- Published
- 2014-06
- Pages
- 4264-4271
- ISSN
- 1063-6919 (ISSN-L)
- OpenAlex
- W1986273245
- Cited by
- 550
- References
- 22
- FWCI
- 52.69
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.