An Infrared Thermography Model Enabling Remote Body Temperature Screening Up to 10 Meters
Abstract
During the COVID-19 pandemic, temperature screening has emerged as a common practice in the infection control pipeline. In particular, thermal imaging systems have risen in popularity for preliminary screening of individuals with elevated temperatures, especially in high throughput areas. However, remote temperature measurement is intrinsically complex and susceptible to unavoidable influences from the measuring environment. We study the effects of sensor-subject distance on remote temperature readings and present an infrared-based system for rapid temperature screening over long distances (2 m to 10 m). The system applies a state-of-the-art pose estimation algorithm to extract the face box locations, sensor-subject distances, and facial temperatures within a scene. For the use of infrared thermography in humans, we propose a thermal compensation model to correct the temperature of subjects measured at different distances and perform analyses to evaluate the trade-off between missing rate (elevated temperature does not trigger an alarm) and false alarm rate (normal temperature triggers an alarm). The experimental results show our system’s promise to identify subjects with elevated temperatures and the potential to improve temperature screening protocols in different environments.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A single temperature measurement can indicate whether a patient has fever or hypothermia.
“A single temperature measurement can tell us whether the patient has a fever or hypothermia [150,151,152,153,154].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [151]
Cites
OpenPose: Realtime Multi-Person 2D Pose Estimation Using Part Affinity Fields
Cao, Z., Hidalgo, G., Simon, T., Wei, S.-E., & Sheikh, Y. (2021) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2019.2929257 · Cited by 5,536 · see citing works
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,359 · see citing works
Infrared Thermography for Temperature Measurement and Non-Destructive Testing
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J., & Bulnes, F. G. (2014) · Sensors · doi:10.3390/s140712305 · Cited by 1,194 · see citing works
Hand Keypoint Detection in Single Images Using Multiview Bootstrapping
Simon, T., Joo, H., Matthews, I. A., & Sheikh, Y. A. (2017) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2017.494 · Cited by 1,147 · see citing works
Theory and Practice of Radiation Thermometry
(1988) · Wiley eBooks · doi:10.1002/9780470172575 · Cited by 634 · see citing works
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Marins, J. C. B., Lastras, J. A., Carmona, P. M. G., Cano, S. P., García-Concepción, M. Á., & Sillero‐Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 588 · see citing works
Monocular human pose estimation: A survey of deep learning-based methods
Chen, Y., Tian, Y., & He, M. (2020) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2019.102897 · Cited by 455 · see citing works
Public health interventions and SARS spread, 2003
Bell, D. M., & World Health Organization Working Group on Prevention of International and Community Transmission of SARS (2004) · Emerging Infectious Diseases · doi:10.3201/eid1011.040729 · Cited by 272 · see citing works
Reproducibility of infrared thermography measurements in healthy individuals
Zaproudina, N., Varmavuo, V., Airaksinen, O., & Närhi, M. V. O. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/4/007 · Cited by 247 · see citing works
Analysis of IR thermal imager for mass blind fever screening
Eddie, Y. T., Kawb, G. J. L., & Chang, W.-H. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.05.003 · Cited by 182 · see citing works
Deep Learning-Based Monocular Depth Estimation Methods—A State-of-the-Art Review
Khan, F., Salahuddin, S., & Javidnia, H. (2020) · Sensors · doi:10.3390/s20082272 · Cited by 162 · see citing works
Dell’Isola, G. B., Cosentini, E., Canale, L., Ficco, G., & Dell’Isola, M. (2021) · Sensors · doi:10.3390/s21020346 · Cited by 101 · see citing works
Togawa, T. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/1/004 · Cited by 100 · see citing works
Negishi, T., Abe, S., Matsui, T., Liu, H., Kurosawa, M., Kirimoto, T., & Sun, G. (2020) · Sensors · doi:10.3390/s20082171 · Cited by 99 · see citing works
Sun, G., Nakayama, Y., Dagdanpurev, S., Abe, S., Nishimura, H., Kirimoto, T., & Matsui, T. (2017) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2017.01.007 · Cited by 94 · see citing works
Chiang, M., Lin, P.-W., Lin, L., Chiou, H., Chien, C.-W., Chu, S.-F., & Chiu, W. T. (2008) · Journal of the Formosan Medical Association · doi:10.1016/s0929-6646(09)60017-6 · Cited by 87 · see citing works
Ghassemi, P., Pfefer, T. J., Casamento, J. P., Simpson, R., & Wang, Q. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203302 · Cited by 82 · see citing works
Remote-sensing infrared thermography
Ng, E. Y. K., & Acharya, U. R. (2009) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.931018 · Cited by 71 · see citing works
A Thermal Camera Based Continuous Body Temperature Measurement System
Lin, J.-W., Lu, M.-H., & Lin, Y. (2019) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2019.00208 · Cited by 61 · see citing works
Paramasivam, S., Shen, C. H., Zourmand, A., Ibrahim, A. K., Alhassan, A. M., & Eltirifl, A. F. (2020) · IEEE International Conference on System Engineering and Technology (ICSET) · doi:10.1109/icset51301.2020.9265363 · Cited by 20 · see citing works
Error Analysis of Surface Temperature Measurement by Infrared Sensor
Pokorni, S. J. (2004) · International Journal of Infrared and Millimeter Waves · doi:10.1023/b:ijim.0000047444.90429.06 · Cited by 16 · see citing works
Somboonkaew, A., Rayanasukha, S., Prempree, P., et al. (2020) · Applied Optics · doi:10.1364/ao.388313 · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103 · see citing works
- Authors
- Chin, J. W., Long Wong, K., Chan, T. T., Suhartono, K., & So, R. H. Y.
- Affiliations
- Hong Kong University of Science and Technology (HK)
- Venue
- 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW)
- Publisher
- IEEE
- Published
- 2021-06
- Pages
- 3870-3876
- OpenAlex
- W3186857926
- Cited by
- 16
- References
- 22
- Citations by year
- 2025: 6 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 1
- FWCI
- 3.14
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) (publishedVersion)
- Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
- Funders
- University Grants Committee
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Face recognition and analysis
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Keywords
- infrared thermography, face pose estimation, COVID-19 infection control, false alarm rate, missing rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review